To connect a drain discharge pipe, use a pipe with a minimum bore of 10, and a maximum length of 5 m. Avoid using a riser pipe.
Power supply 20 Single-phase 200 to 230 VAC (50/60 Hz) 14 HRR Series Specifications: 200 to 230 VAC Air-cooled Refrigeration Model HRR012-A-20 HRR018-A-20 HRR024-A-20 HRR030-A-20 Cooling method Air-cooled refrigeration Refrigerant R410A (HFC) Refrigerant charge [kg] 0.38 0.47 Control method PID control Ambient temperature/Humidity/Altitude1, 13 Temperature: 5 to 40C, Humidity: 30 to 70%,
Piping materials for low dew point air When air with a low dew point (40C or less) is required, do not use nylon tubing for the membrane air dryer's downstream piping. A characteristic of nylon tubing is that it is affected by the ambient air, and it may not be possible to obtain the specified low dew point at the end of the tube.
30 A 60 81 148 45 A 36 50 73 133 60 A 74 151 75 A 46 122 146 50 80 A 60 60 55 148 36 73 166 70 44 Series IDF/IDU E Options 4 Refer to How to Order pages 26, 30, 33, 36 and 39 for optional models.
Do not use standard dew point 40C (symbol L) type, standard dew point 60C (symbol S) type and IDG30, 50, 30H, 50H for dehumidifying breathing air. Do not use only outlet air (dried air) in a closed room. Caution 1. Devise a layout which considers the position of purge air discharge ports. Purge air is humid air.
B-1 A-1 B-2 A-2 B-3 A-3 Nil Cable color Circuit 2 1 6 5 3 4 A A B B COM-A/COM COM-B/ Brown Red Orange Yellow Green Blue S Standard cable Cable color Connector D terminal no. Shield 12 13 7 6 9 8 3 Brown Black Red Black Orange Black Vcc GND A A B B B-4 A-4 B-5 A-5 B-6 A-6 Connector B terminal no.
A valve, which might potentially cause a hum or buzz can be very annoying to a patient, so a full wave rectified unit for AC service is often preferred. A DC unit, not requiring a rectifier, is sometimes used in specific applications. Also common is a bumper in a 2-way valve, usually just a flat disk with no sealing action.
A valve, which might potentially cause a hum or buzz can be very annoying to a patient, so a full wave rectified unit for AC service is often preferred. A DC unit, not requiring a rectifier, is sometimes used in specific applications. Also common is a bumper in a 2-way valve, usually just a flat disk with no sealing action.
Manifold overall length Manifold overall length Approx. 29% reduced SY5000 manifold SY5000 3 stations SY3000 manifold SY3000 4 stations Mixed manifold SY5000 3 stations SY3000 4 stations For serial transmission EX260 A B A B A B A B A B A B A B A B A B A 14 A B A 14 A B A 14 A B A 14 A B A 14 A B A 14 Installation space A A A A A A A A B B B B B B B B 12 B 12 B 12 B 12 B 12 B 12 B 136.7 mm
HRS012-A-10 HRS012-W-10 HRS018-A-10 HRS018-W-10 Model Cooling method Refrigerant Control method Ambient temperature/humidity Note 2) Air-cooled refrigeration Water-cooled refrigeration Air-cooled refrigeration Water-cooled refrigeration R407C (HFC) PID control Temperature: 5 to 40C, Humidity: 30 to 70% Clear water, 15% ethylene glycol aqueous solution Note 5) Circulating fluid Note 3) Circulating
KQ2TW P.153 Use to four-branch a line. P.150 Male run tee KQ2Y Use to branch a female thread in the same direction and at a 90 angle.
3 q u t y u o A !9 r e @0 !0 !2 !5 !6 !4 i A w A-A Component Parts No. Description Material Note No.
CH1 and CH2. 13 A Thermo-chiller Compact Dual/Basic Type for Lasers HRLE Series Heating Capacity HRLE050-A-20 HRLE050-A-20 [50 Hz] [60 Hz] 2.5 2.5 Ambient temperature 45C Ambient temperature 40C Ambient temperature 45C Ambient temperature 40C 2 2 Heating capacity [kW] Heating capacity [kW] 1.5 1.5 Ambient temperature 32C Ambient temperature 32C 1 1 Ambient temperature 25C Ambient temperature
Unit Series AC20C to 40C Dimensions AC20C A Pressure gauge port size G Q F E T L P B C H IN OUT U H L J Pressure gauge (Option) F.R.L.
(A contact) N.O. (A contact) Specifications N.O. (A contact) N.O.
Circulating fluid temperature range 5C to 35C HRG001-A to 015-A By-pass piping set HRG001-W to 015-W Maximum ambient temperature 40C (Relative humidity 85% or less) Makes it possible to use the equipment with a power supply voltage differing from the standard specifications.
Provides a stable supply of dry air even under high demand conditions with an inlet air temperature of 60C. IDU3D to 6D: 60C IDU8D to 37C1: 55C IDU55C, 75C: 50C Series IDF Can accommodate an inlet air temperature of 40C System efficiency is improved by using a high performance heat exchanger.
x Depth 580 HRSE018-A-23 HRSE024-A-23 HRSE012-A-23-T 48 Height 790 x Width 470 x Depth 580 HRSE018-A-23-T HRSE024-A-23-T IDH Selection Warning 1.
Just like a relay, these devices open or close a mechanical contact with the power of a solenoid. The principle of operation is the same as a relay, but a contactor is designed for high-voltage and large current. RS232C A standard for serial communication.