There were no hits with the full part number, but there were 1 hits in the keyword search.
Product Information » New Products Search Results
, 200, 300 40 100, 200, 300, 500 50 200, 300, 500 63 200, 300, 500 Courtesy of Steven Engineering, Inc. !
A I L A B I L I T Y 12 25, 50, 100 20 25, 50, 100, 200 32 50, 100, 200, 300 40 100, 200, 300, 500 50 200, 300, 500 63 200, 300, 500 Courtesy of Steven Engineering, Inc. !
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 525, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence (Only Rod Side), Cushion: Air cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Port
Magnet: D (Built-in), Series: BA2 (with End Lock), Mounting: L (Axial Foot), Tube Material: Aluminum Tube, Bore Size: 50mm, Port Thread: Rc, Stroke: 25mm, Rod Boot: w/o Gaiter w/Cushion Both Sides, Cushion: Air Cushion, Lock Position: R (Front Lock), Release Type: L (Locking), Auto Switch: J59--Solid State, Gen. Purpose, 2 Wire, Lead Wire or Prewired Connector: L (3m)
Magnet: D (Built-in), Series: BA2 (with End Lock), Mounting: L (Axial Foot), Tube Material: Aluminum Tube, Bore Size: 50mm, Port Thread: Rc, Stroke: 500mm, Rod Boot: w/o Gaiter w/Cushion Both Sides, Cushion: Air Cushion, Lock Position: R (Front Lock), Release Type: L (Locking), Auto Switch: J59--Solid State, Gen. Purpose, 2 Wire, Lead Wire or Prewired Connector: L (3m)
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 525, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence (Only Rod Side), Cushion: Air cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Port
Magnet: Built-in, Series: with End Lock, Mounting: Axial Foot, Tube Material: Aluminum Tube, Bore Size: 50mm, Port Thread: Rc, Stroke: 25mm, Rod Boot: w/o Gaiter w/Cushion Both Sides, Cushion: Air Cushion, Lock Position: Front Lock, Release Type: Locking, Auto Switch: J59--Solid State, Gen. Purpose, 2 Wire, Lead Wire or Prewired Connector: 3m, Number: -
Magnet: Built-in, Series: with End Lock, Mounting: Axial Foot, Tube Material: Aluminum Tube, Bore Size: 50mm, Port Thread: Rc, Stroke: 500mm, Rod Boot: w/o Gaiter w/Cushion Both Sides, Cushion: Air Cushion, Lock Position: Front Lock, Release Type: Locking, Auto Switch: J59--Solid State, Gen. Purpose, 2 Wire, Lead Wire or Prewired Connector: 3m, Number: -
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 520, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence (Only Rod Side), Cushion: Air cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Port thread
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 525, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence (Only Rod Side), Cushion: Air cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Port
Air cylinder series CA2 has been introduced with specifications and dimensions equivalent to the existing CA1 series. Several improvements have been made to the CA2 series including lateral load improvement, increase in cushioning capacity and adoption of?a new cushion seal. There has been enhanced efficiency in handling for cushion valve adjustment, and weight has been reduced by 5 to 15%
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CBA1 50MM DBL-ACT AUTO-SW, ACTUATOR, CBA1/CBA2 TIE-ROD CYL END LOCK, NE, CBA1 50MM DBL-ACT AUTO-SW, 4.18878 lb
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 520, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence (Only Rod Side), Cushion: Air cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Port thread
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 525, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence (Only Rod Side), Cushion: Air cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Port
Magnet: D (Built-in), Series: BA2 (with End Lock), Mounting: L (Axial Foot), Tube Material: Aluminum Tube, Bore Size: 50mm, Port Thread: Rc, Stroke: 300mm, Rod Boot: w/o Gaiter w/Cushion Both Sides, Cushion: Air Cushion, Lock Position: H (Rear Locking), Release Type: L (Locking), Auto Switch: J59--Solid State, Gen. Purpose, 2 Wire, Lead Wire or Prewired Connector: L (3m)
Magnet: Built-in, Series: with End Lock, Mounting: Axial Foot, Tube Material: Aluminum Tube, Bore Size: 50mm, Port Thread: Rc, Stroke: 300mm, Rod Boot: w/o Gaiter w/Cushion Both Sides, Cushion: Air Cushion, Lock Position: Rear Locking, Release Type: Locking, Auto Switch: J59--Solid State, Gen. Purpose, 2 Wire, Lead Wire or Prewired Connector: 3m, Number: -
Type M10/M11 manifold At 300 mm/s 4, 6, 8 fittings are connectable. 32 At 300 mm/s Existing 6, 8, 10, 12 fittings are connectable. Valve size Valve size 50 50 DOWN DOWN Existing At 300 mm/s Possible to drive cylinders Up to 50 Valve size Valve size 63 63 DOWN DOWN (80 at 100 mm/s) Existing Possible to drive cylinders Up to 63 80 Page 30 (125 at 100 mm/s) Sub-plate newly added!
depth 12 6 14 50 Up to 300 301 to 1500 35 32 27 32 20 30 2 14 58 11 58 M8 x 1.25 depth 16 7 18 63 Up to 300 301 to 1500 35 32 27 38 20 32 2 14 58 11 72 M10 x 1.5 depth 16 7 18 80 Up to 300 301 to 1500 40 37 32 50 25 40 3 20 71 13 89 M10 x 1.5 depth 22 10 22 100 Up to 300 301 to 1500 40 37 41 60 30 50 3 20 71 16 110 M12 x 1.75 depth 22 10 26 CG3 JMB MB MB1 * For mounting brackets, refer to