SMC Corporation of America
Elite Part Number Search
Search Results "CDG1TA50-150Z-A93"

Magnet: D (Built-in Magnet), Mounting: T (Head Trunnion), Type: A (Air Cushion), Bore: 50mm, Port Thread Type: Rc (or M5, Depending on Style, Bore Size, and Thread Combination), Stroke: 150mm, Thread: Male Rod End, Suffix for Cylinder: w/o Rod Boot, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewire Connection: L (3m

Magnet: Built-in Magnet, Mounting: Head Trunnion, Type: Air Cushion, Bore: 50mm, Port Thread Type: Rc (or M5, Depending on Style, Bore Size, and Thread Combination), Stroke: 150mm, Thread: Male Rod End, Suffix for Cylinder: w/o Rod Boot, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewire Connection: 3m, Number: -, X

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, CG/CG3 ROUND BODY CYLINDER, NE, 50MM CG DBL-ACT AUTO-SW, 3.96832 lb

A93V A93 V V V No 100 V or less A90V A90 A90V A90 V V IC circuit Relay, PLC 24 V 12 V 2-wire Yes C73C A73C V V V V Connector No 24 V or less C80C A80C V V V V IC circuit Diagnostic indication (2-color indication) Grommet Yes A79W V V Water resistant type auto switches can be mounted on the above models, but in such case SMC cannot guarantee water resistance.

A water-resistant type cylinder is recommended for use in an environment which requires water resistance. 2 1 m lead wire is only applicable to the D-A93.

(Example) CDG1YB32-150Z Cylinder stroke (mm) Refer to Standard Strokes on page 173. * Refer to Ordering Example of Cylinder Assembly on page 173. Applicable Auto Switches/Refer to pages 941 to 1067 for further information on auto switches.

CKG150-150Z/CKP150-150Z CKG163-150Z/CKP163-150Z Auto switch mounting bracket B CKG40-RZ150 CKG150-200Z/CKP150-200Z CKG163-200Z/CKP163-200Z CKG40-RZ200 D-M9/M9W D-M9A/A9 Switch mounting rod 2 Mount the part E of the auto switch mounting bracket so that it is in contact with the cylinder tube.

A water-resistant type cylinder is recommended for use in an environment which requires water resistance. *2 1 m type lead wire is only applicable to D-A93. * Solid state auto switches marked with v are produced upon receipt of order. * Do not indicate suffix N for no lead wire on the D-A3A/A44A/G39A/K39A models. * Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: Without auto switch

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: Without auto switch

Magnet: D (Built-in Magnet), Mounting: T (Head Trunnion), Type: A (Air Cushion), Bore: 50mm, Port Thread Type: Rc (or M5, Depending on Style, Bore Size, and Thread Combination), Stroke: 150mm, Thread: Male Rod End, Suffix for Cylinder: w/o Rod Boot

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: A93, Lead Wire Length

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: A93, Lead Wire Length

Magnet: Built-In, Mounting: Rear Trunnion, Style: Non-lube Air Cushion, Bore Size: 50mm, Thread: Rc (or M5 Depending on Style, Bore Size, and Thread Combinations), Piping: Screw-in Piping, Stroke: 125mm, Stroke Adjust Symbol: None, Rod Boot: None, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: -, Number: -, X Option: -

Magnet: D (Built-in Magnet), Mounting: T (Head Trunnion), Type: A (Air Cushion), Bore: 50mm, Port Thread Type: Rc (or M5, Depending on Style, Bore Size, and Thread Combination), Stroke: 125mm, Thread: Male Rod End, Suffix for Cylinder: w/o Rod Boot, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal