The CLS series cylinder with lock is ideal for applications requiring intermediate and emergency stop and drop prevention. The compact lock unit is lightweight and saves space. A switch is optional on the brake cylinder so the operating state of the lock unit (brake piston) can be detected using the switch signal. By separating the lock mechanism and the brake cylinder, SMC has minimized

Magnet: D (Built-in), Mounting: T (Center Trunnion), Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 200mm, Thread: Rc, Stroke: 400mm

Magnet: D (Built-in), Mounting: T (Center Trunnion), Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 200mm, Thread: Rc, Stroke: 600mm

Magnet: D (Built-in), Mounting: T (Center Trunnion), Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 200mm, Thread: Rc, Stroke: 700mm

Magnet: D (Built-in), Mounting: T (Center Trunnion), Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 200mm, Thread: Rc, Stroke: 300mm

Cylinder (Tube) Inner Diameter(φ): 200, Stroke(mm): 700, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure

Magnet: Built-in, Mounting: Center Trunnion, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 200mm, Thread: Rc, Stroke: 400mm, Option: -, Cylinder Switch Type: -, Lead Wire or Pre-wired Connector: -, Number: -, Lock Unit Built-in Magnet: -, Lock Unit Switch Type: -

Magnet: Built-in, Mounting: Center Trunnion, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 200mm, Thread: Rc, Stroke: 600mm, Option: -, Cylinder Switch Type: -, Lead Wire or Pre-wired Connector: -, Number: -, Lock Unit Built-in Magnet: -, Lock Unit Switch Type: -

Magnet: Built-in, Mounting: Center Trunnion, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 200mm, Thread: Rc, Stroke: 300mm, Option: -, Cylinder Switch Type: -, Lead Wire or Pre-wired Connector: -, Number: -, Lock Unit Built-in Magnet: -, Lock Unit Switch Type: -

Cylinder (Tube) Inner Diameter(φ): 200, Stroke(mm): 700, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure

Magnet: D (Built-in), Mounting: T (Center Trunnion), Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 200mm, Thread: Rc, Stroke: 400mm, Option: Cushion at Both Ends, Cylinder Switch Type: No Switch, Lead Wire or Pre-wired Connector: 0.5m Lead Wire (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch

Magnet: D (Built-in), Mounting: T (Center Trunnion), Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 200mm, Thread: Rc, Stroke: 200mm, Option: Cushion at Both Ends, Cylinder Switch Type: No Switch, Lead Wire or Pre-wired Connector: 0.5m Lead Wire (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch

Magnet: D (Built-in), Mounting: T (Center Trunnion), Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 200mm, Thread: Rc, Stroke: 700mm, Option: Cushion at Both Ends, Cylinder Switch Type: No Switch, Lead Wire or Pre-wired Connector: 0.5m Lead Wire (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch

Magnet: Built-in, Mounting: Center Trunnion, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 200mm, Thread: Rc, Stroke: 400mm, Option: Cushion at Both Ends, Cylinder Switch Type: No Switch, Lead Wire or Pre-wired Connector: 0.5m Lead Wire (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch),

Magnet: Built-in, Mounting: Center Trunnion, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 200mm, Thread: Rc, Stroke: 200mm, Option: Cushion at Both Ends, Cylinder Switch Type: No Switch, Lead Wire or Pre-wired Connector: 0.5m Lead Wire (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch),

Magnet: Built-in, Mounting: Center Trunnion, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 200mm, Thread: Rc, Stroke: 700mm, Option: Cushion at Both Ends, Cylinder Switch Type: No Switch, Lead Wire or Pre-wired Connector: 0.5m Lead Wire (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch),

LEFS40 -850 1103.4 856 1028 14 6 900 LEFS40 -900 1153.4 906 1078 14 6 900 LEFS40 -950 1203.4 956 1128 16 7 1050 LEFS40 -1000 1253.4 1006 1178 16 7 1050 Motor Dimensions [mm] Motor type X W Z Without With Without With Without With V8 137.5 177.5 98.5 138.5 14 14 21 Electric Actuator/Slider Type Belt Drive/Series LEFB Model Selection AC Servo Motor Selection Procedure Step 1 Check the work

780 880 1080 560 660 760 860 1060 700 800 900 1000 1200 60 160 260 360 460 80 180 280 380 480 Dimensions inside ( ) are for a 100 mm stroke.

680 780 880 1080 560 660 760 860 1060 700 800 900 1000 1200 60 160 260 360 460 80 180 280 380 480 Dimensions inside ( ) are for a 100 mm stroke.