Your search for CNA2 returned 24 result(s)
There were no hits with the full part number, but there were 4 hits in the keyword search.
There were no hits with the full part number, but there were 1 hits in the keyword search.
Product Information » New Products Search Results
7 51.5 20.5 33.5 51.5 20.5 26.5 30.5 20.5 39 29 19 29 27 35 67 70 75 19 8 71.5 23.5 39.5 74.5 77.5 33.5 31.5 43.5 33.5 48 38 28 28 42 42 56 84 75 22 9 60.5 32.5 46.5 88.5 88.5 42.5 46.5 52.5 32.5 Solid state auto switch: D-M9B, D-M9N Stroke B Stroke E Auto switch operating range Model A 40 50 150 75 100 10 20 30 125 75 100 150 20 30 125 10 40 50 13-/22-MXQ6(L) 0.5 0.5 0.5 7.5 7.5 9.5 9.5
MDHR2-20, 30 MDHR2-10, 15 H H L L Auto switches of D-M9NV, D-M9PV, D-M9BV, and D-M9AV are used. Auto switches of D-M9N, D-M9P, D-M9B, and D-M9A are used. Auto switches of D-M9NV, D-M9PV, D-M9BV, and D-M9AV are used. Max. Protrusion of Auto Switch from Edge of Body: L, H Max.
[mm] (Reference value) 17 Weight 5.5 Most sensitive position [g] Auto switch model D-M9Nm-5 D-M9Pm-5 D-M9Bm-5 0.5 m (Nil) 7 6 Lead wire length 1 m (M) 13 11 3 m (L) 35 31 5 m (Z) 57 51 17-E683 D-M9m-5
D-M9/D-A9 D-M9 D-M9W D-M9AVL D-M9V D-M9WV D-M9AL D-A9 D-A9V A B A B A B A B 50 23.5 9.0 23.5 11.0 23.5 7.0 19.5 10.5 (13.0) 63 25.5 12.5 25.5 14.5 25.5 10.5 21.5 14.0 (16.5) 80 39.5 19.5 39.5 21.5 39.5 17.5 35.5 21.0 (23.5) ( )D-A96 -15 D-P3DW D-P3DW A B Hs Ht 50 14.5 6.5 41 35 63 16.5 10 47 44 80 30.5 17 55 54 D-P3DW BQ6-032S -16 18 - 7-3. 7-3-1.D-M9D-A9 (-) -17 5~6mm D-A9(V)
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No
Magnet: D (Built-in Magnet), Mounting: F (Rod Flange), Tube Material: Aluminum Tube, Bore Size: 40mm, Thread: Rc, Stroke: 125mm, Bellows/Cushion: Cushion Both Sides
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,
Magnet: Built-in Magnet, Mounting: Rod Flange, Tube Material: Aluminum Tube, Bore Size: 40mm, Thread: Rc, Stroke: 125mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: P5DW--Solid State, 2-color Indication, Magnetic Resist., 2 Wire, Lead Wire or Prewired Connector: 0.3m Cord Length, M12-4 Pin Connector, 3 & 4 Out, Number: -, Made to Order: -