SMC Corporation of America
Elite Part Number Search
Search Results "CDQ2A63-20DCM"

Magnet: Built-in Magnet, Mounting: Both Ends Tapped, Bore Size: 63mm, Port Thread: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 20mm, Body Option: with Rubber Bumper, Auto Switch Groove: None (for 12-25 Bore w/o Magnet; 32-100 Bore w/o Magnet Z must be selected), Auto Switch: No Switch, Lead Wire or Prewired Connector: 1m, Number: 2 pcs. (Or None in the Case of No Switch), Environmental

Magnet: D (Built-in Magnet), Mounting: A (Both Ends Tapped), Bore Size: 63mm, Port Thread: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 20mm, Body Option: C (with Rubber Bumper), Auto Switch Groove: None (for 12-25 Bore w/o Magnet; 32-100 Bore w/o Magnet Z must be selected), Auto Switch: No Switch, Lead Wire or Prewired Connector: M (1m), Number: 2 pcs. (Or None in the Case of No Switch

Magnet: D (Built-in), Mounting: A (Both Ends Tapped), Type: Standard, Bore Size: 63mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 20mm, Body Option: CM (C+M), Auto Switch Groove: None (for 12-25 Bore w/o Magnet), Mounting Bolt: None, Rod End Bracket: None, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: L (3m)

Magnet: Built-in, Mounting: Both Ends Tapped, Type: Standard, Bore Size: 63mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 20mm, Body Option: C+M, Auto Switch Groove: None (for 12-25 Bore w/o Magnet), Mounting Bolt: None, Rod End Bracket: None, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -, Mounting Threads

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, COMPACT, ACTUATOR, CQ2 COMPACT CYLINDER, PE, 63MM CQ2 DBL-ACT AUTO-SW, 2.12632 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, COMPACT, ACTUATOR, CQ2 COMPACT CYLINDER, PE, 63MM CQ2 DBL-ACT AUTO-SW, 2.12632 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, COMPACT, ACTUATOR, CQ2 COMPACT CYLINDER, PE, 63MM CQ2 DBL-ACT AUTO-SW, 1.98416 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, COMPACT W/SCRAPER, ACTUATOR, CQ2 COMPACT CYLINDER, PC, 63MM CQ2 OTHERS (COMBO), 2.12632 lb

Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:

Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:

Magnet: D (Built-in), Mounting: A (Both Ends Tapped), Type: Standard, Bore Size: 63mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 20mm, Body Option: CM (C+M), Auto Switch Groove: Z (Auto Switch Mounting Grooves)

Magnet: D (Built-in Magnet), Mounting: A (Both Ends Tapped), Bore Size: 63mm, Port Thread: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 20mm, Body Option: CM (C+M), Auto Switch Groove: Z (ø12 to ø25, 2 Surfaces; ø32 to ø100, 4 Surfaces), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch),

SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25

SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25,

With auto switch Calculation: (Example) CDQ2DS32-20DCM Cylinder weight: CDQ2BS32-20DC Option weight: Both ends tapped style Rod end male thread Double clevis style 263 g 6 g 43 g 151 g 463 g Auto Switch Mounting Bracket Weight Mounting bracket part no. Applicable bore size (mm) Weight (g) BQ-2 32 to 100 1.5 For the auto switch weight, refer to page 7-9-1.

With auto switch Calculation example: CDQ2DS32-20DCM Basic weight: CDQ2BS32-20DC Additional weight: Both ends tapped Rod end male thread Double clevis 263g 6g 43g 151g Weight/Auto Switch Mounting Bracket Mounting bracket Cylinder bore size Weight(g) BQ-2 32 to 50 1.5 463g Refer to p.5.3-75 for auto switch weight.