Your search for CQ2 returned 17 result(s)
There were no hits with the full part number, but there were 28 hits in the keyword search.
There were no hits with the full part number, but there were 24 hits in the keyword search.
Product Information » New Products Search Results
Magnet: Built-in, Mounting: B [Through Hole (Standard)], Bore Size: Ø100, Port Thread Type: Rc, Water Resistant Seal: FKM Seal, Fluororubber, Stroke: 100mm, Option: Standard (Rod End Female Thread), Auto Switch: F7BA--Solid State, Water Resist., 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: -, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: -, Valves: -, Operating Pressure(MPa): 0.08~1.0, Operating Pressure(MPa): -, Specification
Magnet: D (Built-in), Mounting: B (Through Hole [Standard]), Bore Size: Ø100 mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Water Resistant Seal: V (FKM Seal, Fluororubber), Stroke: 100 mm, Body Option: Standard (Rod End Female Thread), Auto Switch Groove: Z (Auto Switch Mounting Grooves)
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: -, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: -, Valves: -, Operating Pressure(MPa): 0.08~1.0, Operating Pressure(MPa): -, Specification
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -, End Locking: No, Valves: No, Operating Pressure(MPa): -, Operating Pressure(MPa): 0.08 to 1, Specification
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -, End Locking: No, Valves: No, Operating Pressure(MPa): -, Operating Pressure(MPa): 0.08 to 1, Specification
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, COMPACT, WATER RESIS *LQA, ACTUATOR, CQ2 COMPACT CYLINDER, SE, 100MM CQ2 DBL-ACT AUTO-SW, 9.51662 lb
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25
CQ2B40-5D -10D -15D -20D -25D -30D -35D -40D -45D -50D -75D -100D CQ2B50-10D -15D -20D -25D -30D -35D -40D -45D -50D -75D -100D CQ2B63-10D -15D -20D -25D -30D -35D -40D -45D -50D -75D -100D CQ2B80-10D -15D -20D -25D -30D -35D -40D -45D -50D -75D -100D CQ2B100-10D -15D -20D -25D -30D -35D -40D -45D -50D -75D -100D M3 x 25l x 30l x 35l x 40l x 45l x 50l M3 x 25l x 30l x 35l x 40l x 45l x 50l
CQ2B40-5D -10D -15D -20D -25D -30D -35D -40D -45D -50D -75D -100D CQ2B50-10D -15D -20D -25D -30D -35D -40D -45D -50D -75D -100D CQ2B63-10D -15D -20D -25D -30D -35D -40D -45D -50D -75D -100D CQ2B80-10D -15D -20D -25D -30D -35D -40D -45D -50D -75D -100D CQ2B100-10D -15D -20D -25D -30D -35D -40D -45D -50D -75D -100D M8 x 50l x 55l x 60l x 65l x 70l x 75l x 80l x 85l x 90l x 125l x 150l M10
CQ2B80-10D -15D -20D -25D -30D -35D -40D -45D -50D -75D -100D CQ2B100-10D -15D -20D -25D -30D -35D -40D -45D -50D -75D -100D CQ2B32-5D -10D -15D -20D -25D -30D -35D -40D -45D -50D -75D -100D CQ2B40-5D -10D -15D -20D -25D -30D -35D -40D -45D -50D -75D -100D CQ2B50-10D -15D -20D -25D -30D -35D -40D -45D -50D -75D -100D 6.5 14.5 9 5 15 7.5 7.5 9.5 15.5 12.5 2.3-5 Series CQ2 Construction Component
4 6 P NC 21 25 TB 16 20 UA M8 x 1.25 UB 16 20 8H9 10H9 VA Model MHSL3-100D MHSL3-125D Rc 1/4 (G 1/4, NPT 1/4) Rc 3/8 (G 3/8, NPT 3/8) +0.036 0 +0.036 0 0 -0.043 0 -0.052 +0.036 0 +0.036 0 8H9 18h9 10H9 22h9 M10 x 1.5 M10 x 1.5 XA XB 6 8 VB 6 8 WA WB 4 6 Model MHSL3-100D MHSL3-125D +0.036 0 +0.036 0 +0.087 0 +0.100 0 8H9 102H9 10H9 130H9 594 Series MHSL3 Parallel Style Air Gripper/3-Finger
SB, counterbore depth SC P .C.D.R (Mounting hole) Auto switch mounting groove positions (4 locations) MHS3-100D MHS3-125D 10 10 10 10 40 40 40 40 5 6.4 5 10 6.4 13 90 12 5 15 7 90 (mm) I G 63 84 FZ 10 12 FX 59 74 FY 54 68 CA 18 23.5 EC 28 30 EO 40 46 DC 66 82 DO 78 98 M 4 6 B 134 166 K 15 21 AC 6 8 J 38 52 AA 96 122 AB 90 114 NA 34 40 L +0.036 0 +0.036 0 NB Model MHS3-100D MHS3-125D CB 30.6
(Example) CHDQB50-100D Applicable Auto Switches: Refer to pages 347 to 406 for further details on each auto switch.
(Example) CHDQB50-100D Applicable Auto Switches/Refer to pages 431 to 490 for further details on each auto switch.