Load Current and Load Current Range Internal Voltage Drop Indicator Lamp (Lit at ON Condition) Applications H O W T O O R D E R S E E N E X T P A G E Auto Switch No Load Voltage 24V AC/DC or less 50mA D-A90L D-A90VL 0 None PLC 48V AC/DC or less 40mA 100V AC/DC or less 20mA 24V DC 5~40mA D-A93L D-A93VL 2.6V or less PLC 100V AC 5~20mA D I M E N S I O N S S E E N E X T P A G E D-A96L D-A96VL

1, previous page)* P Axial piping (see note 2, previous page) FR Buffer and end lock* FP Buffer and axial piping 24v AC DC or less 50mA D-A90L D-A90VL 0 None PLC 48v AC DC or less 40mA 20mA 100v AC DC or less D-A93L D-A93VL 24VDC 5~40mA 2.6V or less PLC Optional Shock Absorber Kits are available; please contact SMC Customer Service for details and availability. 100VAC 5~20mA D-A96L, D-A96VL

This is a legacy product, and replaced byNCDQ2A25-30DMZ, CYL, COMPACT, AUTO-SW, NPT, ACTUATOR, NCQ2 COMPACT CYLINDER, IE, 25MM NCQ2 DBL-ACT AUTO-SW, .50820 lb

When arranging Made to Order 1 and 2 at the same time Cylinder model: CDQ2D40-30DMZ-W-M9BW-XC26AC35 for arc welding V V V V XC89* Spatter resistant spec. for arc welding V V V V Double clevis With coil scraper Mounting D : Double clevis Rod end bracket W: Double knuckle joint Made to Order 1 : XC26A (Double clevis/knuckle width: 16.5 mm) Made to Order 2 : XC35 (With coil scraper) Auto switch

Indicator light Special function Electrical entry Wiring (output) Electrical entry direction 0.5 (Nil) 3 (L) 5 (Z) Applicable loads Type DC AC Perpendicular In-line A96 A96V 3 wire (NPN equiv.) 5V IC circuit A96L A96VL Reed switch Solid state switch Yes A93 A93V 100V Grommet A93L A93VL Relay, PLC 2 wire 24V A90 A90V 5V, 12V No 100V or less IC circuit A90L A90VL F9N F9NV

Indicator light Special function Electrical entry Wiring (output) Electrical entry direction 0.5 (Nil) 3 (L) 5 (Z) Applicable loads Type DC AC Perpendicular In-line A96 A96V 3 wire (NPN equiv.) 5V IC circuit A96L A96VL Reed switch Solid state switch Yes A93 A93V 100V Grommet A93L A93VL Relay, PLC 2 wire 24V A90 A90V 5V, 12V No 100V or less IC circuit A90L A90VL F9N F9NV

Cylinder model (N)CDQ2WB12-5DCZ -10DCZ -15DCZ -20DCZ -25DCZ -30DCZ (N)CDQ2WB16-5DZ -10DZ -15DZ -20DZ -25DZ -30DZ (N)CDQ2WB20-5DZ -10DZ -15DZ -20DZ -25DZ -30DZ -35DZ -40DZ -45DZ -50DZ (N)CDQ2WB25-5DZ -10DZ -15DZ -20DZ -25DZ -30DZ -35DZ -40DZ -45DZ -50DZ Cylinder model (N)CDQ2WB32-5DZ Cylinder model (N)CDQ2WB63-10DZ -15DZ -20DZ -25DZ -30DZ -35DZ -40DZ -45DZ -50DZ -75DZ -100DZ (N)CDQ2WB80-10DZ

Model C D 45 50 55 60 65 70 75 80 85 90 115 140 55 60 65 70 75 80 85 90 95 100 125 150 65 70 75 80 85 90 95 100 105 130 155 Model C D 65 70 75 80 85 90 95 100 105 130 155 70 75 80 85 90 95 100 105 110 135 160 80 85 90 95 100 105 110 115 120 145 170 Bolt CDQ2WB12-5DC -10DC -15DC -20DC -25DC -30DC CDQ2WB16-5D -10D -15D -20D -25D -30D CDQ2WB20-5D -10D -15D -20D -25D -30D -35D -40D -45D -50D CDQ2WB25

Mounting bolt CDQ2WB12-5DC -10DC -15DC -20DC -25DC -30DC CDQ2WB16-5D -10D -15D -20D -25D -30D CDQ2WB20-5D -10D -15D -20D -25D -30D -35D -40D -45D -50D CDQ2WB25-5D -10D -15D -20D -25D -30D -35D -40D -45D -50D Mounting bolt CDQ2WB32-5D -10D -15D -20D -25D -30D -35D -40D -45D -50D -75D -100D CDQ2WB40-5D -10D -15D -20D -25D -30D -35D -40D -45D -50D -75D -100D CDQ2WB50-10D -15D -20D -25D -30D

80 85 90 95 100 105 110 115 120 145 170 Bolt CDQ2WB32-5D -10D -15D -20D -25D -30D -35D -40D -45D -50D -75D -100D CDQ2WB40-5D -10D -15D -20D -25D -30D -35D -40D -45D -50D -75D -100D CDQ2WB50-10D -15D -20D -25D -30D -35D -40D -45D -50D -75D -100D Bolt CDQ2WB12-5DC -10DC -15DC -20DC -25DC -30DC CDQ2WB16-5D -10D -15D -20D -25D -30D CDQ2WB20-5D -10D -15D -20D -25D -30D -35D -40D -45D -50D CDQ2WB25

Magnet: D (Built-in), Mounting: B (Through Hole [Standard]), Type: Standard, Bore Size: 25mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 10mm, Body Option: Standard (Rod End Female Thread), Auto Switch Groove: Z (Auto Switch Mounting Grooves), Auto Switch: A96V--Reed, DC Volt, AC Volt, LED, Vertical, Lead Wire or Prewired Connector: L (3m)

Magnet: D (Built-in), Mounting: B (Through Hole [Standard]), Type: Standard, Bore Size: 25mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 15mm, Body Option: Standard (Rod End Female Thread), Auto Switch Groove: Z (Auto Switch Mounting Grooves), Auto Switch: A96V--Reed, DC Volt, AC Volt, LED, Vertical, Lead Wire or Prewired Connector: L (3m)

Magnet: D (Built-in), Mounting: B (Through Hole [Standard]), Type: Standard, Bore Size: 25mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 20mm, Body Option: M (Rod End Male Thread), Auto Switch Groove: Z (Auto Switch Mounting Grooves), Auto Switch: A96V--Reed, DC Volt, AC Volt, LED, Vertical, Lead Wire or Prewired Connector: L (3m)

Magnet: D (Built-in), Mounting: B (Through Hole [Standard]), Type: Standard, Bore Size: 25mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 20mm, Body Option: Standard (Rod End Female Thread), Auto Switch Groove: Z (Auto Switch Mounting Grooves), Auto Switch: A96V--Reed, DC Volt, AC Volt, LED, Vertical, Lead Wire or Prewired Connector: L (3m)

Magnet: D (Built-in), Mounting: B (Through Hole [Standard]), Type: Standard, Bore Size: 25mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 25mm, Body Option: Standard (Rod End Female Thread), Auto Switch Groove: Z (Auto Switch Mounting Grooves), Auto Switch: A96V--Reed, DC Volt, AC Volt, LED, Vertical, Lead Wire or Prewired Connector: L (3m)