SMC Corporation of America
Elite Part Number Search
Search Results "CEP1F12-25L-M9BAL"

Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): 0~60, End Locking: No, Valves: No, Operating Pressure(MPa): 0.15~1.0, Specification: Built-in magnet, Auto Switches: M9BA,

Mounting: F (Rod Side Flange), Bore Size: 12mm equiv., Stroke: 25mm, Connector: w/Connector, Sensor Cable Length: L (3m), Auto Switch: M9BA--Solid State, Water Resist., 2 Wire, Horizontal, Lead Wire or Prewired Connector: L (3m), Number: S (1 pc.)

Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): 0~60, End Locking: No, Valves: No, Operating Pressure(MPa): 0.15~1.0, Specification: Built-in magnet, Auto Switches: M9BA,

The CE1 series is a stroke reading cylinder with position feedback. The home position can be anywhere within the cylinder stroke. Measurement is possible throughout the full stroke range. The CE1 series is offered in 6 bore sizes and is auto switch capable.High precision scale cylinder, Resolution: 0.01mm, Special scraper (IP-67), Home position can be anywhere within the cylinder stroke,

Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): 0~60, End Locking: No, Valves: No, Operating Pressure(MPa): 0.15~1.0, Specification: Built-in magnet, Auto Switches: Without

Mounting: F (Rod Side Flange), Bore Size: 12mm equiv., Stroke: 25mm, Connector: w/Connector, Sensor Cable Length: L (3m)

Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): 0~60, End Locking: No, Valves: No, Operating Pressure(MPa): 0.15~1.0, Specification: Built-in magnet, Auto Switches: Without

CEP112 CEP120 Foot Rod side flange

CEP112 CEP120 Foot Front flange Nil C Extension cable 5m Extension cable & connector 10m CEP1L12 CEP1F12 15m CEP1L20 CEP1F20 20m Applicable auto switch types Load voltage Maximum load current & load current range 0.5 (Nil) 3 (L) 5 (Z) Lead wire length (m) Applicable load Electrical entry direction AC DC Wiring (output) Special function Type Indicator light Lateral Vertical 24V or less 24V

Mounting: Rod Side Flange, Bore Size: 12mm equiv., Stroke: 25mm, Connector: w/Connector, Sensor Cable Length: 3m, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: -, Number: -

Mounting: Rod Side Flange, Bore Size: 12mm equiv., Stroke: 25mm, Connector: w/Connector, Sensor Cable Length: 3m, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 1 pc.

Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): 0~60, End Locking: No, Valves: No, Operating Pressure(MPa): 0.15~1.0, Specification: Built-in magnet, Auto Switches: A93, Lead

Mounting: F (Rod Side Flange), Bore Size: 12mm equiv., Stroke: 25mm, Connector: w/Connector, Sensor Cable Length: L (3m), Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal

Mounting: F (Rod Side Flange), Bore Size: 12mm equiv., Stroke: 25mm, Connector: w/Connector, Sensor Cable Length: L (3m), Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: L (3m)

Mounting: F (Rod Side Flange), Bore Size: 12mm equiv., Stroke: 25mm, Connector: w/Connector, Sensor Cable Length: L (3m), Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: S (1 pc.)

Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): 0~60, End Locking: No, Valves: No, Operating Pressure(MPa): 0.15~1.0, Specification: Built-in magnet, Auto Switches: A93, Lead

Model C D 25 30 25 30 25 30 30 35 Mounting bolt M3 x 25l x 30l M3 x 25l x 30l M5 x 25l x 30l M5 x 30l x 35l CQSB12-5S -10S CQSB16-5S -10S CQSB20-5S -10S CQSB25-5S -10S Example) Bolt M3 x 25l 4 pcs. 6.5 Single acting, Spring return Single acting, Spring extend 6.5 Mounting bolt 6.5 Mounting bolt 8.5 Single Acting, Spring Extend Model C D 25 30 25 30 25 30 30 35 Mounting bolt M3 x 25l x 30l

Mounting bolt M3 X 25l X 30l M3 X 25l X 30l M5 X 25l X 30l M5 X 30l X 35l Model C D 25 30 25 30 25 30 30 35 CQSB125S 10S CQSB165S 10S CQSB205S 10S CQSB25-5S 10S 6.5 6.5 6.5 8.5 Single acting/Spring extend Mounting bolt M3 X 25l X 30l M3 X 25l X 30l M5 X 25l X 30l M5 X 30l X 35l Model C D 25 30 25 30 25 30 30 35 CQSB125T 10T CQSB165T 10T CQSB205T 10T CQSB255T 10T 6.5 6.5 6.5 8.5 Note) The