MHZ2-6S/MHZA2-6S MHZ2-25S/MHZL2-25S 4 80 Pressure 0.7 MPa Pressure 0.7 MPa Pressure 0.7 MPa Pressure 0.7 MPa Gripping force (N) Gripping force (N) MHZ 0.6 MPa 0.6 MPa 3 60 0.6 MPa 0.6 MPa 0.5 MPa 0.5 MPa MHF 0.5 MPa 0.5 MPa F 2 40 0.4 MPa 0.4 MPa 0.4 MPa 0.4 MPa MHL 0.3 MPa 0.3 MPa 1 20 0.3 MPa 0.3 MPa MHR 0.25 MPa 0.25 MPa 0 10 20 30 0 20 40 60 80 100 MHK Gripping point L (mm) Gripping point
MHZ2-6S/MHZA2-6S MHZ2-25S/MHZL2-25S 4 80 Pressure 0.7 MPa Pressure 0.7 MPa Pressure 0.7 MPa Pressure 0.7 MPa Gripping force (N) Gripping force (N) MHZ 0.6 MPa 0.6 MPa 3 60 0.6 MPa 0.6 MPa 0.5 MPa 0.5 MPa MHF 0.5 MPa 0.5 MPa F 2 40 0.4 MPa 0.4 MPa 0.4 MPa 0.4 MPa MHL 0.3 MPa 0.3 MPa 1 20 0.3 MPa 0.3 MPa MHR 0.25 MPa 0.25 MPa 0 10 20 30 0 20 40 60 80 100 MHK Courtesy of Steven Engineering,
Station 3 1 13 47.04 Station 4 Station 5 Connector JBZ-25S-3 made by Station 6 J.S.T. Mfg. Co.,Ltd. 1425 Socket side Station 7 Station 8 22 Terminal no.
MHK2-12S 120 12 9 4 9 13 76 Normally open Normally closed MHK2-16S 16 23 6 14.6 20.6 114 DL1 MHK2-20S 20 34 10 16 26 237 L2 MHK2-25S 25 58 14 19 33 443 20MHK2-12C 12 12 4 9 13 76 MHK2-16C 16 25 6 14.6 20.6 115 MHK2-20C 20 44 10 16 26 237 MHK2-25C 25 73 14 19 33 443 Series MHKL2/Long Stroke Type Note) Width at opening (mm) L2 Width at closing (mm) L1 Effective gripping force per finger (N)
MHK2-12S 120 12 9 4 9 13 76 Normally open Normally closed MHK2-16S 16 23 6 14.6 20.6 114 DL1 MHK2-20S 20 34 10 16 26 237 L2 MHK2-25S 25 58 14 19 33 443 20MHK2-12C 12 12 4 9 13 76 MHK2-16C 16 25 6 14.6 20.6 115 MHK2-20C 20 44 10 16 26 237 MHK2-25C 25 73 14 19 33 443 Series MHKL2/Long Stroke Type Note) Width at opening (mm) L2 Width at closing (mm) L1 Effective gripping force per finger (N)
MHK2-20S MHK2-20C 80 60 70 50 Holding force (N) Holding force (N) 60 Allowable moment Pressure 0.6MPa 50 40 Model Allowable moment Pressure 0.6MPa Nm 40 0.5MPa 30 0.5MPa 0.05 MHK2-12S, C 30 0.4MPa 0.4MPa 0.12 MHK2-16S, C 20 20 0.3MPa 0.25 MHK2-20S, C 0.3MPa 10 10 0.49 MHK2-25S, C 0 0 20 40 60 80 20 40 60 80 M: Allowable moment (M = WL) Holding point L(mm) Holding point L(mm) W MHK2-25S MHK2
16) 4 9 13 2.6 O.D. holding:7.0 (31) I.D. holding :8.1 (36) MHK2-16D 16 6 14.6 20.6 4.0 Double acting O.D. holding:10.3 (46) I.D.holding :12.6 (56) MHK2-20D 20 10 16 26 8.3 O.D. holding:18.0 (80) I.D. holding :19.3 (86) MHK2-25D 25 14 19 33 15.5 MHK2-12S 120 12 2.0 (9) 4 9 13 2.7 Normally open Normally closed MHK2-16S 16 5.2 (23) 6 14.6 20.6 4.0 MHK2-20S 20 7.6 (34) 10 16 26 8.4 L1 MHK2-25S
Not available for IDF1D to 3D, IDU22C to 75C. Dust proof filter set (A) (25) (25) (B) (10) Part No.
force per finger Effective value N Action Internal gripping force External gripping force 4 55 9.8 10 MHZ2-10D (N) 17 Double acting Single acting 6 115 30 16 40 MHZ2-16D (N) 10 235 42 20 66 MHZ2-20D (N) Single acting type, normally open 14 430 65 25 104 MHZ2-25D (N) 4 55 6.3 10 MHZ2-10S (N) Normally closed Normally open 6 115 24 16 MHZ2-16S (N) 10 240 28 20 MHZ2-20S (N) 14 435 45 25 MHZ2-25S
MRHQ10 P407090-1 MRHQ10D P407090-3D Switch holder B MRHQ16 MRHQ10S P407090-3S MRHQ20 P407060-1 MRHQ10C P407090-3C Switch case MRHQ25 MRHQ16D P407060-3D MRHQ16S P407060-3S MRHQ16C P407060-3C MRHQ20D P407080-3D MRHQ20S P407080-3S Switch holder A MRHQ20C P407080-3C MRHQ25D P408080-3D Each unit includes two of each of the parts indicated left. Switches are not included with a unit.
Take proper measures to prevent dust or foreign matter from accumulating in this area. (6) (3e) VQZ (3d) (3d) (3c) VZ (3) (9) (3a) VS (3e) (8) Electrical Connection VFN (9) For wiring to DIN terminal, connect the positive (+) polar side with connector terminal no. 1 and the negative () side with connector terminal no. 2 when the rated voltage is DC type. (3e) Magnifying figure (2a) Self-up
, 4D, 6D, 8D Small How to Order Voltage Model Options (No options for standard specification models) 3D 4D 6D 8D C E H 1 IDU 2 4 6 L M R S T Voltage 1 100VAC (50Hz) 100 to 110VAC (60Hz) 200VAC (50Hz) 200 to 220VAC (60Hz) 2 Single phase 240VAC (50Hz) 220 to 240VAC (50Hz) 4 6 220VAC (50Hz) Model Air compressor Refrigerant 2.2kW 3.7kW 5.5kW 7.5kW 1 3D 4D 6D 8D R134a Model and voltage combinations
New Products Guide 2 Air Preparation Equipment, Modular F. R. L., Air Tanks Fittings and Tubing Flow Control Equipment, Exhaust Filters Switches/Sensors Process Valves High Vacuum Equipment Temperature Control Equipment Pneumatic Instrumentation Process Gas Equipment Equipment CAT.E00-7A INDEX New Products Guide 2 Air Preparation Equipment/ Modular F. R. L./Air Tanks Refrigerated Air Dryer
P407090-1 P406090-3D MRHQ10D Switch holder B P406090-3S MRHQ10S P407060-1 P406090-3C MRHQ10C Switch case P406060-3D MRHQ16D P406060-3S MRHQ16S P406060-3C MRHQ16C P407080-3D MRHQ20D P407080-3S MRHQ20S Switch holder A P407080-3C MRHQ20C P408080-3D MRHQ25D Two of each part indicated at the left are included in a unit. Switches are not included with a unit.
Pressure gauge or pressure transducer Temparature Differential pressure gauge or differential pressure transducer gauge g d1 Pressure control d33d1 equipment Flow control 3 valve d2 Air Filter Shut-off Flow meter 10d3 10d1 0d2 3d 3d 3 1 3d 3d 3 2 supply valve Thermometric pipe Test equipment Upstream pressure Downstream pressure measuring tube measuring tube Figure 2 Test circuit of ISO6358
Molded cover L Seal (Length) 2 x M2.6 x 0.45 16 44 8 (2.4) 015 Connector JBZ-25S-3 made by J.S.T. Mfg. Co., Ltd. Connector hood L Terminal no.
2/8 FGX-OM-L011 FGG Series/ (P) 0.02MPa V V () O O 1 (O ) ) 3/8 FGX-OM-L011 FGG Series/ IN/OUT 0.1MPa M12 , INLETOUTLET 67 O V O 40 4/8 FGX-OM-L011 1 1/8 Rc2 Rp1/4 Rp1/4 INLET DRAIN Rp3/4 OUTLET Rc2 1 AG-10S SUS304 JIS B2401-1A-P11 NBR O JIS B2401-4D-P11 FKM M101.5 11 SUS304 M10 SUS304 SUS304 AN-3S SUS316WPA L-27S SUS316 U-8SU-9SU-10S SUS304 SUS304 J-4S SUS316 AL-25S
.: AL-25S) FKM (Part no.: AL-22S) FGGL 1 O-ring Refer to pages 256 and 257 for the replacement element type. AL-25S AL-22S Case fastening parts V-band coupling (Part no.: CY-27S) CY-27S Note) The quantity used for 1 filter is 1 each of the above O-ring etc.
.: AL-25S) FKM (Part no.: AL-22S) FGGL 1 O-ring Refer to pages 256 and 257 for the replacement element type. Case fastening parts V-band coupling (Part no.: CY-27S) Note) The quantity used for 1 filter is 1 each of the above O-ring etc.
R A L L E L T Y P E S I N G L E A C T I N G T Y P E: N O R M A L LY O P E N MHQ2-6D 6 Outside holding force: 3.4 Inside holding force: 6.2 4 MHQ2-10D 10 11 4 Double acting type MHQ2-16D 16 35 6 MHQ2-20D 20 43 10 MHQ2-25D 25 64 14 MHQ2-6S 6 Outside holding force: 1.9 Inside holding force: 1.1 4 Single acting type Normally open type MHQ2-10S 10 8 4 MHQ2-16S 16 27 6 MHQ2-20S 20 34 10 MHQ2-25S