Mounting: Through Hole, Bore Size: 50mm, Stroke: 15mm, Option: Standard (Rod End Female Thread), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Rated Voltage: 24 VDC, Electrical Entry: M Plug Connector With Lead Wire, Surge Voltage Suppressor: W/O Surge Voltage Suppressor, Manual Override

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~50, End Locking: No, Valves: Presence, Operating Pressure(MPa): 0.15~0.7, Support bracket: Through-hole

Mounting: B (Through Hole), Bore Size: 50mm, Stroke: 15mm, Option: Standard (Rod End Female Thread), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Rated Voltage: 5 (24 VDC), Electrical Entry: M (M Plug Connector With Lead Wire), Surge Voltage Suppressor: W/O Surge Voltage Suppressor, Manual

Mounting: B (Through Hole), Bore Size: 50mm, Stroke: 50mm, Option: Standard (Rod End Female Thread), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Rated Voltage: 5 (24 VDC), Electrical Entry: M (M Plug Connector With Lead Wire), Surge Voltage Suppressor: W/O Surge Voltage Suppressor, Manual

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~50, End Locking: No, Valves: Presence, Operating Pressure(MPa): 0.15~0.7, Support bracket: Through-hole

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 40, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~50, End Locking: No, Valves: Presence, Operating Pressure(MPa): 0.15~0.7, Support bracket: Head-end flange

Mounting: G (Head Flange), Bore Size: 50mm, Stroke: 40mm, Option: Standard (Rod End Female Thread), Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs.

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 40, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~50, End Locking: No, Valves: Presence, Operating Pressure(MPa): 0.15~0.7, Support bracket: Head-end flange

Mounting: Through Hole, Bore Size: 50mm, Stroke: 40mm, Option: Standard (Rod End Female Thread), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Rated Voltage: 24 VDC, Electrical Entry: M Plug Connector With Lead Wire, Surge Voltage Suppressor: -, Manual Override: -, Piping: -, Port Thread

Mounting: B (Through Hole), Bore Size: 50mm, Stroke: 40mm, Option: Standard (Rod End Female Thread), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Rated Voltage: 5 (24 VDC), Electrical Entry: M (M Plug Connector With Lead Wire)

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 40, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~50, End Locking: No, Valves: Presence, Operating Pressure(MPa): 0.15~0.7, Support bracket: Foot type,

Mounting: L (Foot), Bore Size: 50mm, Stroke: 40mm, Option: Standard (Rod End Female Thread), Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: L (3m), Number: 2 pcs.

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 40, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~50, End Locking: No, Valves: Presence, Operating Pressure(MPa): 0.15~0.7, Support bracket: Foot type,

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL W/VALVE, ACTUATOR, CVQ COMPACT CYLINDER W/VALVE, NC, CVQ 50MM CYL W/VALVE, 1.76369 lb

The CVQ series is designed so that the D-M9* series auto switch can be mounted flush with the cylinder profile.Compact cylinder with attached valve, Space, energy, and labor savings, Choose from side and axial piping, Bore size *: 32, 40, Stroke *: 5~100, Compact Cylinder with Solenoid Valve, COMPACT CYLINDER W/VALVE, 557, 1000 lb

Bore Size: 12mm, Symmetric Type: L (Symmetric), Stroke: 40mm, Adjuster: w/o Adjuster, Function: Standard, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, 0.5M

Magnet: D (Built-in), Mounting: A [Double End Tapped [ø32 - ø50]], Bore Size: Ø40 mm, Port Thread: M Thread [ø12-ø25]; Rc [ø32-ø100], Stroke: 40 mm, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal

Magnet: D (Built-in), Mounting: B [Through Hole (Standard)], Bore Size: Ø25 mm, Port Thread: M Thread [ø12-ø25]; Rc [ø32-ø100], Stroke: 40 mm, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal

Magnet: D (Built-in), Mounting: B [Through Hole (Standard)], Bore Size: Ø40 mm, Port Thread: M Thread [ø12-ø25]; Rc [ø32-ø100], Stroke: 40 mm, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal

Magnet: D (Built-in), Mounting: B [Through Hole (Standard)], Bore Size: Ø50 mm, Port Thread: M Thread [ø12-ø25]; Rc [ø32-ø100], Stroke: 40 mm, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal