Guide Suffix: T (2 Axes), Bore Size: 25mm, Port Thread: Rc, Stroke: 500mm, Adjuster: B (Shock Absorbers (2 pcs)), Auto Switch: Y59B--Solid State, Gen. Purpose, 2 Wire, Horizontal, 0.5M
Guide Suffix: T (2 Axes), Bore Size: 25mm, Port Thread: Rc, Stroke: 500mm, Adjuster: B (Shock Absorbers (2 pcs)), Auto Switch: Z73--Reed, DC Volt., AC Volt, 2 Wire, LED, 0.5M
Guide Suffix: T (2 Axes), Bore Size: 25mm, Port Thread: Rc, Stroke: 500mm, Adjuster: B (Shock Absorbers (2 pcs)), Auto Switch: Z73--Reed, DC Volt., AC Volt, 2 Wire, LED, 0.5M, Lead Wire or Prewired Connector: L (3m)
Guide Suffix: T (2 Axes), Bore Size: 25mm, Port Thread: Rc, Stroke: 500mm, Adjuster: B (Shock Absorbers (2 pcs)), Auto Switch: Y59B--Solid State, Gen. Purpose, 2 Wire, Horizontal, 0.5M, Lead Wire or Prewired Connector: L (3m)
Type: Rodless Cylinder, Cylinder Inner Diameter(Ø): 25, Stroke(mm): 500, Max.
Type: Rodless Cylinder, Cylinder Inner Diameter(Ø): 25, Stroke(mm): 500, Max.
Guide Suffix: 2 Axes, Bore Size: 25mm, Port Thread: Rc, Stroke: 500mm, Adjuster: Shock Absorbers (2 pcs), Auto Switch: Y59B--Solid State, Gen. Purpose, 2 Wire, Horizontal, 0.5M, Lead Wire or Prewired Connector: -, Number: -
Guide Suffix: 2 Axes, Bore Size: 25mm, Port Thread: Rc, Stroke: 500mm, Adjuster: Shock Absorbers (2 pcs), Auto Switch: Z73--Reed, DC Volt., AC Volt, 2 Wire, LED, 0.5M, Lead Wire or Prewired Connector: -, Number: -
With no external leakage, the CY series can be used in many diverse environments. Magnetically coupled cylinders have a wide range of applications, and save mounting space. Loads and moments are possible through the use of integrated guides. A variety of guides can be used to achieve the necessary accuracy or allowable moment needed for your application. CY is available in 9 bore sizes,
With no external leakage, the CY series can be used in many diverse environments. Magnetically coupled cylinders have a wide range of applications, and save mounting space. Loads and moments are possible through the use of integrated guides. A variety of guides can be used to achieve the necessary accuracy or allowable moment needed for your application. CY is available in 9 bore sizes,
With no external leakage, the CY series can be used in many diverse environments. Magnetically coupled cylinders have a wide range of applications, and save mounting space. Loads and moments are possible through the use of integrated guides. A variety of guides can be used to achieve the necessary accuracy or allowable moment needed for your application. CY is available in 9 bore sizes,
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, RODLESS, ACTUATOR, CY1H/CY1L GUIDED CYLINDER, IE, 25MM CY1H/CY1L DBL-ACT A/S, 23.47923 lb, ModelStandard stroke (mm) 1002003004005006008001000CY1HT255.16.27.38.39.410.412.514.6
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, RODLESS, ACTUATOR, CY1H/CY1L GUIDED CYLINDER, IE, 25MM CY1H/CY1L DBL-ACT A/S, 24.91223 lb, ModelStandard stroke (mm) 1002003004005006008001000CY1HT255.16.27.38.39.410.412.514.6
When this happens, the sum of the load factors () is the total of all such moments. 500 500 500 2.
70 100 300 500 1000 W Piston speed (mm/s) Graph (1) Moment M1, M3 M2 Allowable Moment (Static moment/Dynamic moment) 100 100 85 96 CY1HT32 CY1HT25 CY1H25 CY1H20 CY1H15 CY1HT32 CY1HT25 CY1H25 64 56 (Nm) 50 40 30 50 40 30 20 28 26 M1 M2 M3 M2 M3 M1 Model Model 20 CY1H20 CY1H15 16 Moment (Nm) Moment (Nm) CY1H10 CY1H25 1.5 2.5 1.5 28 26 28 13 10 10 CY1H15 CY1HT25 10 16 10 56 85 56 2 2.5 3 4
Load weight W Max. load weight 50 40 30 20 W CY1HT32 (kg) CY1H25,CY1HT25 25 Model Wmax CY1H20 16 4.0 CY1H10 Load weight kg CY1H15 10 9 9.0 CY1H15 5 4 3 2 CY1H10 16.0 CY1H20 CY1H25 25.0 1 CY1HT25 W 40.0 CY1HT32 0.5 70 100 300 500 1000 W Piston speed mm/s
Load Mass W CY1HT32 W Maximum Load Mass (kg) 50 40 30 CY1H25,CY1HT25 25 CY1H20 20 16 Load mass kg CY1H15 Wmax Model 10 9 CY1H10 4.0 CY1H10 5 4 3 CY1H15 9.0 2 CY1H20 16.0 1 CY1H25 W 25.0 CY1HT25 0.5 CY1HT32 40.0 70 100 300 500 1000 W Piston speed mm/s Graph (1) Moment M1,M3 M2 Allowable Moment (Static moment/Dynamic moment) 100 100 85 96 CY1HT32 CY1HT25 CY1H25 CY1H20 CY1H15 CY1HT32 CY1HT25
How to Order Standard Elements 500 EM A 074 Element seal material/Operating temperature range Micromesh element symbol Symbol Element seal material Non-asbestos Fluororesin NBR FKM Operating temperature range(C) 0 to 150 0 to 120 0 to 80 0 to 120 Symbol Element composition symbol A Note) Element composition symbol Stainless steel 304 Stainless steel 316 T Note) 100 500 N V Note) Not possible
Contents Bore size (mm) CY1HT25-PS CY1HT32-PS CY1HT25-PS CY1HT32-PS 25 32 Set of left nos. @8, @9, #0, #1, #2, #3 @8 @9 #0 #1 #2 #3 Wear ring A Special resin Wear ring B Special resin Note 1) Seal kit includes @8 to #3. Order the seal kit, based on each bore size. Seal kit includes a grease pack (10 g). Order with the following part number when only the grease pack is needed.
Guide Suffix: T (2 Axes), Bore Size: 25mm, Port Thread: Rc, Stroke: 100mm