SMC Corporation of America
Elite Part Number Search
Search Results "CY3R25TN-500-M9NL"

light 8 3.2 DC (+) Brown 2.6 2 4.6 4 2.7 4 2.8 Most sensitive position 6 2.8 22 500 (3000) 20 2.7 OUT Black 3.2 2.6 DC () Blue 9.5 6 Most sensitive position 22 500 (3000) 4 D-M9B, D-M9BV Precautions OUT (+) Brown Be sure to read before handling.

Operating speed Make sure to connect a speed controller to the cylinder and adjust its speed to 500 mm/s or less. If a load is to be attached to the end of the rod, adjust the speed to the maximum speed shown in Graph (1) or less, in accordance with the added mass.

Lead wire length symbols:0.5 mNil (Example) M9BV 3 m L (Example) M9NL 5 m Z (Example) F59AZ (Example) When ordering with an air gripper When ordering auto switches only 61 D-F8PLMHZ 2-16D-F8NS61 Auto switches marked with a symbol are produced upon receipt of order. Note 1) Take note of hysteresis with 2 color indication type switches.

Lead wire length symbols:0.5 mNil (Example) M9BV 3 m L (Example) M9NL 5 m Z (Example) F59AZ (Example) When ordering with an air gripper When ordering auto switches only 61 D-F8PLMHZ 2-16D-F8NS61 Auto switches marked with a symbol are produced upon receipt of order. Note 1) Take note of hysteresis with 2 color indication type switches.

Between case and signal ground: 500 VAC for 1 min.

Lead wire length symbols: 0.5 mNil (Example) M9N 3 m L M9NL 5 m Z M9NZ 8-8-23 23 Series MXP8 Specifications MXP8 8 M5 x 0.8 Model Cylinder bore size (mm) Port size Fluid Action Operating pressure Proof pressure Air Double acting 0.15 to 0.7 MPa 1.05 MPa -10 to 60C 50 to 500 mm/s (with metal stopper: 50 to 200 mm/s) Rubber bumper None (with metal stopper) Non-lube Standard equipment Ambient

Operating speed Make sure to connect a speed controller to the cylinder and adjust its speed to 500 mm/s or less. If a load is to be attached to the end of the rod, adjust the speed to the maximum speed shown in Graph (1) or less, in accordance with the added mass.

INDEX 270 Series EX600 SI Unit Specifications All Units Common Specifications 10 to 50C 20 to 60C 35 to 85% RH (No dew condensation) 500 VAC for 1 minute between external terminals and FE 500 VDC, 10 M or more between external terminals and FE Operating temperature range Storage temperature range Operating humidity range Withstand voltage Note) Insulation resistance Note) Environmental resistance

Between case and signal ground: 500 VAC for 1 min.

Between case and signal ground: 500 VAC for 1 min.

For details about auto switches with pre-wire connector, refer to page 8-30-52. 8-5-8 9 Air Slide Table Series MXQ Specifications 6 8 12 16 20 25 Bore size (mm) Rc 1/8 M5 x 0.8 Piping port size Air Fluid Double acting Action 0.15 to 0.7 MPa Operating pressure 1.05 MPa Proof pressure MX 10 to 60C Ambient and fluid temperature MTS 50 to 500 mm/s (Adjuster option/Metal stopper: 50 to 200 mm/

Lateral load Operating pressure: 1 MPa 1000 200 300 500 Stroke Eccentric distance 100 100 Load weight (kg) 10 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 63 Allowable lateral load (N) 50 40 63 1 32 25 20 50 40 10 32 0.1 25 10 100 200 300 500 1000 Maximum piston