For EX126 SI unit mounting F kit, 25 pins P kit, 26 pins P kit, 20 pins T kit L kit with 0.6 m lead wire L kit with 1.5 m lead wire L kit with 3.0 m lead wire M kit 26 pins Double wiring of 1st to 8th stations Double wiring of 9th to 12th stations EX250-SPR1 EX250-SAS EX250-SMJ EX250-SDN1 EX250-SCA1 EX250-IE1 EX250-IE2 EX250-IE3 EX250-EA1 EX250-EA2 EX500-Q001 EX500-Q001-X1 EX500-Q101 EX500

EX500-Q001 EX500-Q001-X1 EX500-Q101 EX500-Q101-X1 EX250-SDN1 EX250-SPR1 EX250-SMJ2 EX250-SAS3 EX250-SAS5 EX250-SAS7 EX250-SAS9 EX250-SCA1A EX250-SCN1 EX250-SEN1 EX250-IE1 EX250-IE2 EX250-IE3 EX250-EA1 EX600-ZMV1 EX600-SDN1 EX600-SDN2 EX600-SMJ1 EX600-SMJ2 EX600-SPR1 EX600-SPR2 EX600-DXPB EX600-DXNB EX600-DXPC EX600-DXNC EX600-DXPC1 EX600-DXNC1 EX600-DXPD EX600-DXND EX600-DYPB EX600-DYNB EX600

Note that the EX250-SPR1 PROFIBUS DP compatible SI unit is to be discontinued as of November 2022. *1 Since the nuts are embedded in the SUP/EXH block rInput block wEX250 SI unit Manifold Exploded View S IE DN1 1 EX250 EX250 ZK2 Combination Manifold Block type Communication protocol 1 M12 connector, 2 inputs 2 M12 connector, 4 inputs 3 M8 connector, 4 inputs DN1 DeviceNet (Negative common

EX250-SDN1 EX250-SPR1 EX250-IE1 EX250-IE2 EX250-IE3 EX250-EA1 SV1000-78A Refer to page 32.

Refer to page 161 for the EX600 and y on page 169 for the EX250.

Straight connector type EX9-AC002-2 200 EX260 EX123/124/126 EX500 EX600 EX245 EX250 EX120/121/122 EX140 EX180 EX510 M8/M12 ATEX 40.7 44.7 EX9-AC0022 M12 M12 6.6 SI unit type Type 1 Type 2 Type 3 Type 1 Type 2 2 EX250-SDN1 EX250-SMJ2 EX250-SCA1A Terminal no. Core wire color 1 5 2 Terminal no.

GW unit IP65 SI unit with SV valves: IP65 64 64 SI unit with VQC valves: IP67 EX250-SDN1 (SI unit), EX250-SPR1 (SI unit), EX250-IE1/-IE2/-IE3 (Input block) Two major protocols are available: DeviceNetTM (EX250-SDN1) and Profibus-DP compatible (EX250-SPR1) Controls up to 32 solenoid valves and receives up to 32 inputs depending on the number of input units installed.

VQC1000 VQC4000 VQC2000 EX250-SDN1 EX250-SPR1 EX250-IE1 EX250-IE2 EX250-IE3 EX250-EA EX500-Q001 EX500-Q001-X1 EX500-Q101 EX500-Q101-X1 EX240-SDN2 EX240-SPR1 EX240-IE1 EX240-EA2 EX240-EA4 VVQC1000-F25-1 VVQC1000-P26-1 VVQC1000-P20-1 VVQC1000-T0-1 DeviceNet (COM) SI unit 1 PROFIBUS-DP (COM) M12, 2 inputs Input block 2 M12, 4 inputs M8, 4 inputs End plate assembly 3 1: Standard 2: DIN

VQC4000 VQC1000 VQC2000 EX250-SDN1 EX250-SPR1 EX250-IE1 EX250-IE2 EX250-IE3 EX250-EA EX500-Q001 EX500-Q001-X1 EX500-Q101 EX500-Q101-X1 EX240-SDN2 EX240-SPR1 EX240-IE1 EX240-EA2 EX240-EA4 VVQC1000-F25-1 VVQC1000-P26-1 VVQC1000-P20-1 VVQC1000-T0-1 DeviceNet (COM) SI unit 1 PROFIBUS-DP (COM) M12, 2 inputs Input block 2 M12, 4 inputs M8, 4 inputs End plate assembly 3 1: Standard 2: DIN

Please refer to page 13 for Series EX250 single SI unit dimensions. For details of the Series EX250 SI unit, please refer to the technical instruction manual. Seal 0 1 Metal seal Rubber seal 12 SI unit Serial Unit (SI Unit) Dimensions/EX250 DeviceNet PROFIBUS-DP CC-Link SI SI SI PW PW(V) RUN PWR(V) MOD/NET PWR(V) PWR STATION NO.

Before Use Fieldbus device EX250-IE1/EX250-IE2/EX250-IE3 Summary of Product Elements EX250-IE2 EX250-IE1 EX250-IE3 2 2 2 Thank you for purchasing an SMC EX250-IE1/EX250-IE2/EX250-IE3 Fieldbus device. Please read this manual carefully before operating the product and make sure you understand its capabilities and limitations. Please keep this manual handy for future reference.

1-2-38 35 Series SV Series EX250 Serial Wiring with Input/Output Unit Dimensions: Series SV1000 for EX250 Serial Wiring with Input/Output Unit Tie-rod base manifold: SS5V1-W10S1DU D B C3, N1 C4, N3 C6, N7 (S, R, RS) (-D) Stations When P, E port outlets are indicated on the U side or D side, the P, E ports on the opposite side are plugged.

Series 10-SV How to Order Tie-rod base 10 Clean series SS5V W D 05 10S1 1 QW U Enclosure IP67 Series 1 2 3 SV1000 SV2000 SV3000 Input block stations Input block type Nil 1 None 1 station Nil 1 2 3 Without input block M12, 2 inputs M12, 4 inputs M8, 4 inputs EX250-IE1 EX250-IE2 EX250-IE3 8 8 stations Note) The symbol is nil for no SI unit.

Disable BOOTP/DHCP Selecting this function will disable the EX250 from retrieving its IP addressfrom the BOOTP/DHCP Server, and will cause the EX250 to retain its current configuration during the next power up.

B DIN rail mounting bracket [-D] VVQ1000-57A for {F, L, M, P, S (EX500) kit} VVQC1000-57A-S for {S (EX250) kit} VVQC1000-57A-T for {T, S (EX126) kit} 17 SOL. A 5 Station 7 SOL. B 18 SOL. A 6 Station 8 SOL.

Series EX250 Serial Wiring with Input/Output Unit IP67 compliant . Series SV Serial Wiring with Input/Output Unit. How to Order . Series EX250 Serial Wiring with Input/Output Unit. Dimensions . Series SV1000 for EX250 Serial Wiring with Input/Output Unit. Series SV2000 for EX250 Serial Wiring with Input/Output Unit. Series SV3000 for EX250 Serial Wiring with Input/Output Unit.

Input side EX250-IE18 EX250-IE2/34 Mounting and Installation : Input numbers are assigned to stations from SI unit side to input side in order. : Each bit of data read into master 4bytes shows ON/OFF of sensor connected to input block. Starting from LSB of first byte (Offset 0), input numbers are assigned to all bits in numeric order.

when the valve power supply decreases or when the input block fuse is detected to be broken (EX250-SDN1-X102 does not disconnect the I/O connection).

;;-l I aurt in _ Except EXs00 EX250, and EXl20 sera 4ran foids 5/16 one-tor'ch fiti ng +mrn onJroucn tting J 8mm one{ouch fitlil|g I'lo lls,ts!!!1]I!

ADDRESS EX250 CAUTION indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Caution: FE connection Connect the ground terminal to the ground. Resistance to the ground should be 100 or less.