SMC Corporation of America
Elite Part Number Search
Search Results "EX260-SEC1"

EX260-SDN1 EX260-SDN2 EX260-SDN3 EX260-SDN4 EX260-SPR1 EX260-SPR2 EX260-SPR3 EX260-SPR4 EX260-SPR5 EX260-SPR6 EX260-SPR7 EX260-SPR8 EX260-SMJ1 EX260-SMJ2 EX260-SMJ3 EX260-SMJ4 EX260-SEC1 EX260-SEC2 EX260-SEC3 EX260-SEC4 EX260-SPN1 EX260-SPN2 EX260-SPN3 EX260-SPN4 EX250-SDN1 EX250-SPR1 EX250-SMJ2 EX250-SAS3 EX250-SAS5 EX250-SAS7 EX250-SAS9 EX250-SCA1A EX250-SEN1 EX250-IE1 EX250-IE2 EX250-IE3

EtherCAT 32 EX260-SEC1 EX260-SEC2 M12 SDB 16 EX260-SEC3 EX260-SEC4 SFA PROFINET 32 EX260-SPN1 EX260-SPN2 M12 SFB 16 EX260-SPN3 EX260-SPN4 SEA EtherNet/IP32 EX260-SEN1 EX260-SEN2 M12 SEB 16 EX260-SEN3 EX260-SEN4 SDTA AS-Interface, Negative common (PNP), (8 in/8 out, 31 slave modes, 2 power supply systems) EX250-SAS3 PROFIBUS DP VQC 4/5 VQC 4/5 SDTB AS-Interface, Negative common (PNP), (4

-SMJ4 EX260-SMJ3 32 EX260-SEC2 EX260-SEC1 EtherCAT M12 16 EX260-SEC4 EX260-SEC3 32 EX260-SPN2 EX260-SPN1 For details about the EX series (Serial transmission system), refer to Best Pneumatics No. 1-1 and the Operation Manual.

Model EX260-SEC1/3 EX260-SEC2/4 EX260-SPN1/3 EX260-SPN2/4 EX260-SEN1/3 EX260-SEN2/4 EtherCAT Note 2) EtherNet/IP Note 2) Protocol PROFINET Note 2) Applicable system Volume 1(Edition 3.8) Volume 2(Edition 1.9) Conformance Test Record V .1.1 XML file PROFINET Specification Version 2.2 GSD file EDS file Version Note 1) Configuration file Note 3) SEC1: 0/32 SEC3: 0/16 SEC2: 0/32 SEC4: 0/16 SPN1

Model EX260-SEC1/3 EX260-SEC2/4 EX260-SPN1/3 EX260-SPN2/4 EX260-SEN1/3 EX260-SEN2/4 EtherCAT Note 2) EtherNet/IP Note 2) Protocol PROFINET Note 2) Applicable system Volume 1(Edition 3.8) Volume 2(Edition 1.9) Conformance Test Record V .1.1 XML file PROFINET Specification Version 2.2 GSD file EDS file Version Note 1) Configuration file Note 3) SEC1: 0/32 SEC3: 0/16 SEC2: 0/32 SEC4: 0/16 SPN1

-SDN1, EX260-SDN3, EX260-SMJ1, EX260-SMJ3, EX260-SPR1, EX260-SPR3, EX260-SPR5, EX260-SPR7, EX260-SEN1, EX260-SEN3, EX260-SEC1, EX260-SEC3, EX260-SPL1, EX260-SPL3, EX500-Q102, EX500-S103 EX9-OET1, EX9-OEP1 EX126D-SMJ1 EX250-SMJ2 EX260-SDN2, EX260-SDN4, EX260-SMJ2, EX260-SMJ4, EX260-SPR2, EX260-SPR4, EX260-SPR6, EX260-SPR8, EX260-SEN2, EX260-SEN4, EX260-SEC2, EX260-SEC4 EX500-Q002 EX9-OET2,

SI Unit (Safety Communication) EX260 PS1 F Series Part no.

P/E port entry on one side or Top ported Plug wEX260 SI unit EX260 Note) It can be selected only if no symbol or S or V or B is selected for the pilot and the piping.

<EX260-SEC1/-SEC2/-SEC3/-SEC4> Fieldbus interface connector layout 6 RUN L/A IN L/A OUT PWR(V) PWR BUS OUT: M12 4-pole Socket D-coded 1 No.

._3d_items_collection = {}; } SMC AN15-C08 silencer with 8mm fitting, AN SILENCER $5.50 + Add to Quote Add To Cart Add to Cart SMC EX260-SEC1 ether cat interface 32 pnp, EX300

For the parameter setting in EX600-SEC1/2 compatibility mode, refer to the operation manual for the EX600-SEC1/2 (EX-OMO0027).

Flickering Flashing Single Flash Double Flash -22No.EX-OMO0027-A Specification Specifications Model EX600-SEC1 EX600-SEC2 Communication Protocol EtherCAT (Conformance Test Record V.1.2) Communication speed 100 Mbps Occupied area (Number of inputs/outputs) (512 inputs/512 outputs) Max.

End plate bracket (EX600-ZMA2) 6 12 EX600-SEC1 / EX600-SEC2 Displays the status of the power supply voltage for control and input. PWR Displays the status of the power supply voltage for outputs. Wiring PWR(V) Thank you for purchasing an SMC EX600 Series Fieldbus system.

with surge voltage suppressor 24 VDC, 1.0 W or less (SMC) Power supply 24 VDC, 2 A Fail safe HOLD/CLEAR/Forced power ON Protection Short-circuit protection Enclosure IP67 (Manifold assembly) Standards CE Marking, UL (CSA), RoHS compliant Weight 300 g Note) The setting file can be downloaded from the SMC website, http://www.smcworld.com Output EX600-SEN3/4 SI Unit (EX600-SECl) Model EX600-SEC1

(Positive common) Number of outputs 32 outputs (8/16/24/32 outputs selectable) Load Solenoid valve with surge voltage suppressor 24 VDC, 1.5 W or less (SMC) Power supply 24 VDC, 2 A Fail safe HOLD/CLEAR/Forced power ON Protection Short-circuit protection Enclosure IP67 (Manifold assembly) Standards CE marking, UL (CSA), RoHS recognition Weight 0.6 lbs (300 g) SI Unit (EX600-SECl) EX600-SEC1

Type: Wireless System, Communication Protocol: EtherCAT, Output Format: PNP (Negative Common), Type: SI Unit, Number of Inputs/Outputs: -, Disconnection Detection: -, Connector: -, Mounting Method: -, Dimension: -, Option: -

EX250 EX260 EX126 EX120 Common Dimensions Mixed Mounting Manifold Exploded View Fitting, Plug Part Nos.

"EX260-SPN (EX260-SPN-1, EX260-SPN-2, and so on)" should be entered in the Device name box for each EX260-SPN1/2 or EX260-SPN3/4 set with the hardware configuration. The same name must be used for the connected SI unit device name (page 18) and the device name set in the hardware configuration.

EX260-VPN1 (12) EX260-VPN1 (16) 4 bytes 4 bytes EX260-VPN1 ( 4) EX260-VPN1 ( 8) 2 bytes 2 bytes Vacuum / Release shared Vacuum / Release Refer to Section 3.4 and Section 5.1. EX260-VPN1 (12) EX260-VPN1 (16) 4 bytes 4 bytes Pressure value / Channel status 2 bytes Pressure value / Channel status 0...15 Refer to Section 5.2.