Output Specification: 0 (NPN output (common (+)), Applicable Valve Manifold: 2 (Plug-in manifold), Mounting Specification: A (Mounting vertically on DIN rail)
The EX510 series makes it possible to connect more valves and sensors than with conventional units. With the introduction of the EX510 series, only a power supply cable to the GW unit is required, resulting in wire-savings. Setting the address for the SI unit, output unit and input unit is no longer required, only the address for the GW unit needs to be set.
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, SI UNIT, VALVE, EX500 SERIAL INTERFACE UNIT, 22, EX500 NO SIZE RATING, 1.25978 lb
Nil EX510-S001 NPN output (+ COM.) WEB catalog N EX510-S101 PNP output ( COM.) Refer to the WEB catalog and the Operation Manual for the details of the EX510 Gateway-type Serial Transmission System.
EX510-S001 Nil N EX510-S101 P.1715 to 1717 PNP output (COM.)
For details on the EX510 Gateway-type Serial Transmission System, refer to the WEB catalog or the Best Pneumatics No. 1 and the Operation Manual. Please download the Operation Manual via SMC website, http://www.smcworld.com The valve arrangement is numbered as the 1st station from the D side.
4PCA-1557688 (Socket) 3 4 EX260 EX123/124/126 EX500 EX600 EX245 EX250 EX120/121/122 EX140 EX180 EX510 M8/M12 ATEX 7.8 7.8 Marker tag Marker tag Socket connector pin assignment B-coded (Reverse key) M12 SPEEDCON Type 1 Type 2 Type 3 Type 1 Type 2 50 5000 47.3 22.5 2 1 5 !
EX510-S001 PNP output (COM.) EX510-S101 Refer to the WEB catalog and the Operation Manual for the details of the EX510 Gateway-type Serial Transmission System.
EX510-S002A Nil N K Note 6) Special wiring spec. (Except double wiring) PNP output (COM.)
Use SMC branch connector (product No.: EX510-LC1) and branch cable (product No.: EX510-FC ).
-C Table of Contents Thank you for purchasing an SMC fieldbus system EX510 series.
Table of Contents Thank you for purchasing an SMC fieldbus system EX510 series.
EX510-S002A Nil N PNP output (COM.)
EX510-S002A Nil N PNP output (COM.)
Symbol NPN output (+ COM) Nil EX510-S002B Stations N PNP output ( COM) EX510-S102B PWB U side D side COM 7 0 1 1 3 2 6 15 14 10-SS5Z3-60S6BD-05U (-Q)1 set (Type 60S6B 5-station manifold part no.) 10-SZ3160-5LOZ-C6 (-Q)2 sets (Single solenoid part no.) 10-SZ3260-5LOZ-C6 (-Q)3 sets (Double solenoid part no.) The asterisk denotes the symbol for assembly.
Compliant Sensor: N (NPN Output), Connector Type: 4 (Terminal Box Type, External Power Supply)
Communication Protocol: PR1 (PROFIBUS DP®)