/200/300-A-40 CH2 . 9-13 9.4.5 HRL100-A-40-T2 CH1 . 9-14 9.4.6 HRL200-A-40-T2 CH2 . 9-14 9.4.7 HRL300-A-40-T2 CH1 . 9-15 9.4.8 HRL100/200/300-A-40-T2 CH2 . 9-15 9.4.9 HRL300-A-40-T3 CH1 . 9-16 9.4.10 HRL300-A-40-T3 CH2 . 9-16 9.4.11 HRL100-W-40 CH1 . 9-17 9.4.12 HRL200-W-40 CH1 . 9-17 9.4.13 HRL100/200-W-40 CH2 . 9-18 9.4.14 HRL100-W-40-T2 CH1 . 9-18 HRL Series HRX-OM-X037 Contents 9.4.15
Fig. 8-8 Cooling Capacity (HRL100/200/300-A-20) Documents HRL Series 8-8 HRX-OM-Y098 Chapter 8 Documents 8.5 Pump Capacity 8.5.1 HRL100-A-20 CH1 0.6 60 0.5 50 Circulating fluid outlet Pressure [MPa] 0.4 40 Lifting head [m] Usable flow rate range 0.3 30 0.2 20 Circulating fluid return 0.1 10 0 0 0 10 20 30 40 50 60 70 80 90 100 110 120 Circulating fluid flow[L/min] Fig. 8-9 Pump capacity(HRL100
40 HRS090 Standard type 0.5 5 to 35 Indoor use (400 V as standard) Outdoor installation IPX4 (400 V as standard) HRS100/150 Standard type 1.0 5 to 35 HRSH090 Inverter type 0.1 5 to 40 Indoor use (400 V as standard, 200 V as an option) (Only 200 V as an option) Outdoor installation IPX4 HRSH Inverter type 0.1 5 to 35 (400 V as standard, 200 V as an option) (Only 200 V as an option)
8.5 Pump Capacity 8.5.1 HRL100A20 CH1 0.6 60 0.5 50 Circulating fluid outlet Lifting head [m] Pressure [MPa] 0.4 40 0.3 30 Usable flow rate range 0.2 20 Circulating fluid return 0.1 10 0 0 0 10 20 30 40 50 60 70 80 90 100 110 120 Circulating fluid flow [L/min] Fig. 8-9 Pump capacity(HRL100-A-20 CH1) 8.5.2 HRL200A20 CH1 0.6 60 0.5 50 Circulating fluid outlet Lifting head [m] Pressure [MPa]
Cooling Capacity: CH1: 9 kW; CH2: 1 kW, Pipe Thread: N [NPT (Rc-NPT Thread Adapter Set is Included)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (60 Hz)], DI Option: DI (CH1, CH2 w/Electric Conductivity Control), Pump Option: -
Cooling Capacity: 100 (CH1: 9 kW; CH2: 1 kW), Pipe Thread: N [NPT (Rc-NPT Thread Adapter Set is Included)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (60 Hz)], DI Option: DI (CH1, CH2 w/Electric Conductivity Control)
Cooling Capacity: CH1: 9 kW; CH2: 1 kW, Pipe Thread: Rc, Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], DI Option: DI (CH1, CH2 w/Electric Conductivity Control), Pump Option: -
Cooling Capacity: 100 (CH1: 9 kW; CH2: 1 kW), Pipe Thread: Rc, Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], DI Option: DI (CH1, CH2 w/Electric Conductivity Control)
Cooling Capacity: CH1: 9 kW; CH2: 1 kW, Pipe Thread: N [NPT (Rc-NPT Thread Adapter Set is Included)], Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], DI Option: -, Pump Option: -
Cooling Capacity: 100 (CH1: 9 kW; CH2: 1 kW), Pipe Thread: N [NPT (Rc-NPT Thread Adapter Set is Included)], Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)]
(C) Correction factor 1.25 1.11 1 0.90 0.63 2 to 25 30 32 35 40 2 to 25 30 32 35 40 45 2 to 25 30 32 35 40 2 to 25 30 32 35 40 2 to 25 30 32 35 40 Note) For the water-cooled type, the correction factor is determined to 1 in an ambient temperature range of 2 to 45C.
After tightening by hand, the barb fitting type should be tightened by an additional 1/4 rotation using an appropriate wrench. 2. After tightening by hand, the barb elbow type should be tightened by an additional 1/2 rotation using an appropriate wrench. 2) M5 1. After tightening by hand, the barb fitting type should be tightened by an additional 1/6 rotation using a suitable tool. 2.
VM SUP blocking disk assembly SY30M-40-2A SY50M-40-1A SY70M-40-1A EXH blocking disk assembly Series SY3000 SY5000 SY7000 SY30M-40-1A SY50M-40-1A SY70M-40-1A XT34 Label for blocking disk If the blocking disk assembly is ordered using the manifold specification sheet and ordered at the same time as the manifold, the position where the blocking disk assembly is inserted will be labeled and
d1 = 2.5, L1 = 18 (max.) for size 15; minimum machining diameter for d1 is 0.1mm. d1 = d3 for sizes 20 to 40.
both solenoids located at one end SX Type 41P manifold SX3*40 (Cv=0.22) SX5*40 (Cv=0.53) VQ1*11 (Cv=0.3) VQ plug lead types External pilot valves required SX3*40 (Cv=0.22) SX5*40 (Cv=0.53) SX7*40 (Cv=0.9) VQ0*51 (Cv=0.15) SY3*40 (Cv=0.22) SY5*40 (Cv=0.53) VQ0*51 (Cv=0.15) SY3*40 (Cv=0.22) SY5*40 (Cv=0.53) SY7*40 (Cv=0.9) SX Type 42P manifold Non plug-in valves Porting: Body ported or true
thread R (1)
D1 T T Metric Size L4 L5 A1 A2 M Max.
d1 = 2.5, L1 = 18 (max.) for size 15 ; minimum machining diameter for d1 is 0.1 mm. d1 = d3 for sizes 20 to 40. A parallel keyway is used on the long shaft for size 40. Minimum machining diameter for d1 is 0.1 mm.
d1 = 2.5, L1 = 18 (max.) for size 15 ; minimum machining diameter for d1 is 0.1 mm. d1 = d3 for sizes 20 to 40. A parallel keyway is used on the long shaft for size 40. Minimum machining diameter for d1 is 0.1 mm.
d1 = 2.5, L1 = 18 (max.) for size 15 ; minimum machining diameter for d1 is 0.1 mm. d1 = d3 for sizes 20 to 40. A parallel keyway is used on the long shaft for size 40. Minimum machining diameter for d1 is 0.1 mm.