Cooling Capacity: CH1: 26 kW; CH2: 1 kW, Pipe Thread: N [NPT (Rc-NPT Thread Adapter Set is Included)], Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], DI Option: -, Pump Option: -
Cooling Capacity: 300 (CH1: 26 kW; CH2: 1 kW), Pipe Thread: N [NPT (Rc-NPT Thread Adapter Set is Included)], Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)]
Cooling Capacity: CH1: 26 kW; CH2: 1 kW, Pipe Thread: Rc, Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], DI Option: CH2 w/Electric Conductivity Control, Pump Option: 20 L/min, CH2 Optical Head
Cooling Capacity: 300 (CH1: 26 kW; CH2: 1 kW), Pipe Thread: Rc, Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], DI Option: CH2 w/Electric Conductivity Control, Pump Option: T2 (20 L/min, CH2 Optical Head)
ZPA-T2-B8 ZPA-T2-B10 ZPA-T2-B12 ZPA-T2-B16 Adapter assembly part no.
ZPA-T2-B8 ZPA-T2-B10 ZPA-T2-B12 ZPA-T2-B16 Adapter assembly part no.
(C) Correction factor 1.25 1.11 1 0.90 0.63 2 to 25 30 32 35 40 2 to 25 30 32 35 40 45 2 to 25 30 32 35 40 2 to 25 30 32 35 40 2 to 25 30 32 35 40 Note) For the water-cooled type, the correction factor is determined to 1 in an ambient temperature range of 2 to 45C.
16 6 40 46 25 9.5 48 57.5 32 16 63 79 40 0 68 68 Step motor, Stroke: 300 mm Step motor Top surface of table and motor are level.
Cooling Capacity: 300 (CH1: 26 kW; CH2: 1 kW), Pipe Thread: N [NPT (Rc-NPT Thread Adapter Set is Included)], Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], DI Option: DI (CH1, CH2 w/Electric Conductivity Control), Pump Option: T2 (20 L/min, CH2 Optical Head)
Cooling Capacity: CH1: 26 kW; CH2: 1 kW, Pipe Thread: N [NPT (Rc-NPT Thread Adapter Set is Included)], Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], DI Option: CH2 w/Electric Conductivity Control, Pump Option: 39 L/min, CH2 Optical Head, Size 300 Only
Cooling Capacity: CH1: 26 kW; CH2: 1 kW, Pipe Thread: N [NPT (Rc-NPT Thread Adapter Set is Included)], Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], DI Option: DI (CH1, CH2 w/Electric Conductivity Control), Pump Option: 39 L/min, CH2 Optical Head, Size 300 Only
Cooling Capacity: 300 (CH1: 26 kW; CH2: 1 kW), Pipe Thread: N [NPT (Rc-NPT Thread Adapter Set is Included)], Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], DI Option: CH2 w/Electric Conductivity Control, Pump Option: T3 (39 L/min, CH2 Optical Head, Size 300 Only)
Cooling Capacity: 300 (CH1: 26 kW; CH2: 1 kW), Pipe Thread: N [NPT (Rc-NPT Thread Adapter Set is Included)], Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], DI Option: DI (CH1, CH2 w/Electric Conductivity Control), Pump Option: T3 (39 L/min, CH2 Optical Head, Size 300 Only)
As the connector cover dimensions are different, take the dimensions below into consideration during the design process. 40 40 65 24 40 40 40 24 An air cylinder with an auto switch cannot be installed in the shaded area. Battery-less absolute encoder connector cover dimensions 181 CE/UL-compliance List For CE/UL-compliant products, refer to the tables below and the following pages.
ZPA-T2-B8 ZPA-T2-B10 ZPA-T2-B12 ZPA-T2-B16 Adapter assembly part no.
14 NY M4 x 0.7 8 70 50 5 46 69.8 61.4 M4 x 12 M5 x 40 11 NX M5 x 0.8 9 63 50 5 49.7 69.8 61.4 M4 x 12 M5 x 40 9 NW M5 x 0.8 9 70 50 5 47.5 69.8 61.4 M4 x 12 M5 x 40 9 NV M4 x 0.7 8 63 50 5 49.7 69.8 61.4 M4 x 12 M5 x 40 9 NU M5 x 0.8 9 70 50 5 47.5 69.8 61.4 M4 x 12 M5 x 40 11 NT M5 x 0.8 9 70 50 5 46 69.8 61.4 M3 x 12 M5 x 40 12 NM2 M4 x 0.7 8 50 36* 4.5* 40.1 69.8 61.4 M4
Do not apply strong impact or an excessive moment while mounting the product or a workpiece. LEC SS-T LEC Y LEC Y If an external force over the allowable moment is applied, it may cause play in the guide or an increase in the sliding resistance. 3.
, 50) U ZP (40, 50) C ZP (40, 50) B ZP40D ZPT4-A6, A8 ZPT4-B6, B8 B01, N01 T01 ZP2-40UCL ZP2-50UCL P. 72 P. 73 Adapter Assembly Part No.