Description Qty Applicable model Anti-quake bracket A Anti-quake bracket B 2 2 4 4 HRR010-A/W-10/20-Y HRR012/018-A/W-10/20-Y HRR-TK001 Nut (M8) HRR024/030-A/W-20-Y Bolt (M8) HRR050-A/W-20-Y Mounting of anti-quake bracket 1. Remove the cap from M8 stud bolt. (4pcs) 2. Mount the anti-quake bracket A. (Recommended torque : 12.5Nm) 3. Mount the anti-quake bracket B.
0 5 10 15 20 25 Circulating fluid flow rate [L/min] Circulating fluid flow rate [L/min] HRR050-A-20, HRR050-W-20 0.5 Circulating fluid pressure [MPa] Outlet: 60 Hz 0.4 0.3 Outlet: 50 Hz Return port Return port (Option Z) 0.2 Allowable operating range 0.1 0 0 10 20 30 40 Circulating fluid flow rate [L/min] Required Facility Water Flow Rate 012 018 024 030 HRR -W HRR010-W-20 30 20 Facility
Cooling Capacity: 050 [4600/5100, (50/60 Hz)], Cooling Method: A (Air-cooled), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], Option: DMU (DM+U)
Cooling Capacity: 050 [4600/5100, (50/60 Hz)], Cooling Method: A (Air-cooled), Pipe Thread: F [G (w/Rc-G Conversion Fitting Set)], Option: DMU (DM+U)
Cooling Capacity: 050 [5000/5900, (50/60 Hz)], Cooling Method: W (Water-cooled), Pipe Thread: Rc, Option 1: DM (w/Electric Conductivity Control Function, Applicable to DI Water Piping)
Cooling Capacity: 050 [5000/5900, (50/60 Hz)], Cooling Method: W (Water-cooled), Pipe Thread: F [G (w/Rc-G Conversion Fitting Set)], Option 1: DM (w/Electric Conductivity Control Function, Applicable to DI Water Piping)
Cooling Capacity: 050 [4600/5100, (50/60 Hz)], Cooling Method: Air-cooled, Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], Option: DM+U
Cooling Capacity: 050 [5000/5900, (50/60 Hz)], Cooling Method: Water-cooled, Pipe Thread: Rc, Option 1: w/Electric Conductivity Control Function, Applicable to DI Water Piping, Option 2: -
Cooling Capacity: 050 [5000/5900, (50/60 Hz)], Cooling Method: Water-cooled, Pipe Thread: F [G (w/Rc-G Conversion Fitting Set)], Option 1: w/Electric Conductivity Control Function, Applicable to DI Water Piping, Option 2: -
Cooling Capacity: 050 [4600/5100, (50/60 Hz)], Cooling Method: A (Air-cooled), Pipe Thread: Rc, Option: DMU (DM+U)
Cooling Capacity: 030 [2500/3000, (50/60 Hz)], Cooling Method: W (Water-cooled), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], Option 1: DM (w/Electric Conductivity Control Function, Applicable to DI Water Piping)
Cooling Capacity: 010 [1000/1100, (50/60 Hz)], Cooling Method: W (Water-cooled), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], Option 1: DM (w/Electric Conductivity Control Function, Applicable to DI Water Piping)
Cooling Capacity: 030 [2500/3000, (50/60 Hz)], Cooling Method: Water-cooled, Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], Option 1: w/Electric Conductivity Control Function, Applicable to DI Water Piping, Option 2: -
Cooling Capacity: 010 [1000/1100, (50/60 Hz)], Cooling Method: Water-cooled, Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], Option 1: w/Electric Conductivity Control Function, Applicable to DI Water Piping, Option 2: -
Cooling Capacity: 050 [5000/5900, (50/60 Hz)], Cooling Method: W (Water-cooled), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], Option 1: None
Cooling Capacity: 050 [5000/5900, (50/60 Hz)], Cooling Method: W (Water-cooled), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], Option 1: None, Option 2: Y (w/Feet and No Rack Mounting Brackets)
Cooling Capacity: 050 [5000/5900, (50/60 Hz)], Cooling Method: W (Water-cooled), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], Option 1: M (Applicabe to DI Water Piping)
Cooling Capacity: 050 [5000/5900, (50/60 Hz)], Cooling Method: Water-cooled, Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], Option 1: None, Option 2: -
Cooling Capacity: 050 [5000/5900, (50/60 Hz)], Cooling Method: Water-cooled, Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], Option 1: None, Option 2: w/Feet and No Rack Mounting Brackets
Cooling Capacity: 050 [5000/5900, (50/60 Hz)], Cooling Method: Water-cooled, Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], Option 1: Applicabe to DI Water Piping, Option 2: -