Your search for HRS returned 21 result(s)
There were no hits with the full part number, but there were 12 hits in the keyword search.
There were no hits with the full part number, but there were 10 hits in the keyword search.
Product Information » New Products Search Results
e q IN OUT t Modular F.R.L. e q r IN OUT w r w AC-A AC-B AR30(K)-B/AR40(K)-B q t AR50(K)-B/AR60(K)-B e IN OUT q t r w e IN OUT r w Component Parts No.
. 9-11 9.5.2 HRS012--20,HRS018--20, HRS024--20 . 9-11 9.6 Pump capacity . 9-12 9.6.1 HRS012--10-(BJM), HRS018--10-(BJM) . 9-12 9.6.2 HRS012--20-(BGJM), HRS018--20-(BGJM), HRS024--20-(BGJM) . 9-12 9.6.3 HRS012--10-T, HRS018--10-T, HRS012--10-MT, HRS018--10-MT . 9-13 9.6.4 HRS012--20-T, HRS018--20-T, HRS024--20-T . 9-13 9.6.5 HRS012--20-MT, HRS018--20-MT, HRS024--20-MT . 9-14 9.7 Required facility
HRS012/018--10-T/MT HRS012/018/024/030--20-T HRS012/018/024/030--20-MTNote 1) Applicable model Rated flow50/60Hz Note 2) 3) 7(0.36MPa)/10(0.42MPa) 10(0.44MPa)/14(0.40MPa) 10(0.32MPa/)/14(0.32MPa) Pump 18/22 Maximum flow rate (50/60 Hz) L/min Maximum pump head (50/60 Hz) m 55 70 60 Output W 320 550 Circuit protector 15A (10 A for standard) A 15 Recommended earth leakage breaker capacity 15
024 030 HRR -W HRR010-W-20 30 20 Facility water flow rate [L/min] Facility water flow rate [L/min] HRR030-W 25 15 HRR024-W 20 15 10 10 HRR018-W 5 5 HRR012-W 0 0 0 10 20 30 40 0 10 20 30 40 50 Facility water inlet temperature [C] Facility water inlet temperature [C] * This is the required facility water flow rate at the circulating fluid rated flow and the cooling capacity listed in the
25C Ambient temperature 2C 0.5 0.5 Ambient temperature 2C 0 0 15 20 25 Circulating fluid temperature [C] 15 20 25 Circulating fluid temperature [C] HRLE050-W-20 HRLE050-W-20 [50 Hz] [60 Hz] 2 2 Heating capacity [kW] Heating capacity [kW] 1.5 1.5 Facility water temperature 25C, 32C, 40C Facility water temperature 25C, 32C, 40C 1 1 0.5 0.5 0 0 15 20 25 Circulating fluid temperature [C] 15
Power consumption P: 20 [kW] Q = P = 20 [kW] Cooling capacity = Considering a safety factor of 20%, 20 [kW] x 1.2 = V: Power supply voltage P 24 [kW] Power consumption e Derive the heat generation amount from the output. Output (shaft power, etc.) W: 13 [kW] w Derive the heat generation amount from the power supply output.
Please contact us for the latest version.sales@ocaire.com, MAIN PC BOARD / HRS012-W-20-T, OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING, .00000 lb
Please contact us for the latest version.sales@ocaire.com, MAIN PC BOARD / HRS012-W-20, OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING, .00000 lb
Please contact us for the latest version.sales@ocaire.com, MAIN PC BOARD / HRS012-W-20-MT, OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING, .00000 lb
PIPE ASSY, HRS012~024-A/W-20, CHILLER, 729, 400 lb
~024-A/W-10/20, CHILLER, 729, 100 lb
For the HRS012/018/024/030 option “T” (high-pressure pump) and the HRS050/060, after 8000 hours, alarm code “AL28” (pump maintenance) will be activated.
We recommend that you check for leaks and replace the mechanical seal at this time. Consider requesting maintenance from a maintenance company. We can recommend service providers if needed.
Type: -, Cooling Method: -, Cooling Capacity: 1,100/1,300 W (50/60 Hz), Piping thread type: Rc, Optional specifications: High pump head specification
Type: -, Cooling Method: -, Cooling Capacity: 1,100/1,300 W (50/60 Hz), Piping thread type: G (PT-G conversion fitting set included), Optional specifications: High pump head specification
Type: -, Cooling Method: -, Cooling Capacity: 1,100/1,300 W (50/60 Hz), Piping thread type: NPT (PT-NPT conversion fitting set included), Optional specifications: High pump head specification
Type: Thermo-Chiller, Cooling Method: Water Cooling, Cooling Capacity: 1,100/1,300 W (50/60 Hz), Piping thread type: G (PT-G conversion fitting set included), Optional specifications: High pump head specification