Your search for HRS returned 21 result(s)
There were no hits with the full part number, but there were 12 hits in the keyword search.
There were no hits with the full part number, but there were 10 hits in the keyword search.
Product Information » New Products Search Results
) Note 20) Note 20) Note 20) Note 20) Note 20) Note 20) Note 15) The combination of metal bowl: 2 and 8 is not available.
Low noise 60 ZK2A07 (Silencer exhaust) ZK2G07 (High-noise reduction silencer exhaust) 46 dB (A) 1 50 1 Nozzle size: 0.7 (Under SMCs measurement conditions) 40 Noise level [dB (A)] 30 Reduces high-frequency range from 2000 to 20 Hz. 20 10 0 200 2000 20 Frequency [Hz] Suction flow Improved by up to approx. 20% Max. suction flow [L/min (ANR)] Nozzle size Exhaust type 40 80 Approx. 20% High-noise
-A-20-(BJM) . 9-5 9.3.2 HRS050-W-20-(BJM) . 9-6 9.4 Cooling capacity . 9-7 9.4.1 HRS050--20-(BJM) . 9-7 9.5 Heating capacity . 9-7 9.5.1 HRS050-A-20-(BJM) . 9-7 9.5.2 HRS050-W-20-(BJM) . 9-7 9.6 Pump capacity. 9-8 9.6.1 HRS050--20-(BJM) . 9-8 9.7 Required facility water flow (For water-cooled type) . 9-8 9.8 Compliance . 9-9 HRS Series HRX-OM-O021 Contents 9.9 Sample DoC. . 9-10 9.10 Daily
(HRS050-A-20-(BJMTW)) 9.5.2 HRS040-W-20-(BJMTW) 1500 1500 Facility water temperature Facility water temperature 1200 1200 Heating capacity[W] Heating capacity[W] 40 40 900 900 32 32 25 25 600 600 20 20 5 5 300 300 0 0 5 10 15 20 25 30 35 40 5 10 15 20 25 30 35 40 Circulating fluid temperature[] Circulating fluid temperature[] 60H 50H Fig. 9-6 Heating capacity(HRS050-W-20-(BJMTW)) HRS Series
Cooling Capacity: Cooling Capacity: 4700/5100W, 50/60 Hz, Cooling Method: Water-cooled Refrigeration, Thread: Rc, Option: B + J
Type: -, Cooling Method: -, Cooling Capacity: 4,700/5,100 W (50/60 Hz), Piping thread type: Rc, Optional specifications: With earth leakage circuit breaker / With automatic water supply
Type: -, Cooling Method: -, Cooling Capacity: 4,700/5,100 W (50/60 Hz), Piping thread type: NPT (PT-NPT conversion fitting set included), Optional specifications: With earth leakage circuit breaker / With automatic water supply
Type: -, Cooling Method: -, Cooling Capacity: 4,700/5,100 W (50/60 Hz), Piping thread type: NPT (PT-NPT conversion fitting set included), Optional specifications: With earth leakage circuit breaker / With automatic water supply
Cooling Capacity: 050 (Cooling Capacity: 4700/5100W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: BJ (B + J)
Cooling Capacity: 050 (Cooling Capacity: 4700/5100W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: Rc, Option: BJ (B + J)
Cooling Capacity: 050 (Cooling Capacity: 4700/5100W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: BJ (B + J)
Cooling Capacity: 050 (Cooling Capacity: 4700/5100W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: Rc, Option: BJ (B + J)
Type: Thermo-Chiller, Cooling Method: Air-Cooling, Cooling Capacity: 4,700/5,100 W (50/60 Hz), Piping thread type: G (PT-G conversion fitting set included), Optional specifications: None
Cooling Capacity: 050 (Cooling Capacity: 4700/5100W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set)
0 5 10 15 20 25 Circulating fluid flow rate [L/min] Circulating fluid flow rate [L/min] HRR050-A-20, HRR050-W-20 0.5 Circulating fluid pressure [MPa] Outlet: 60 Hz 0.4 0.3 Outlet: 50 Hz Return port Return port (Option Z) 0.2 Allowable operating range 0.1 0 0 10 20 30 40 Circulating fluid flow rate [L/min] Required Facility Water Flow Rate 012 018 024 030 HRR -W HRR010-W-20 30 20 Facility