20 Water-cooled refrigeration Cooling capacity CH1, 2 total 050 5 kW Option Water-cooled refrigeration Cooling method Nil None M Deionized water (Pure water) piping W Water-cooled refrigeration Power supply Options C and P are not available for the HRLE050. 20 Single-phase 200 to 230 VAC (50/60 Hz) Specifications Model HRLE050-W-20 Cooling method Water-cooled refrigeration Refrigerant R410A
Applicable model HRS-WL003 HRS090-mm-20/40 Parts List q No.
. 5-18 5.8.4 Command:LOC Key-lock setting (R) . 5-19 5.8.5 Command:LOC Key-lock setting (W) . 5-20 5.8.6 Command:STR Saves data (W) . 5-21 5.9 Negative response . 5-22 Chapter 6 Communication alarm function . 6-1 6.1 Communication alarm occurs . 6-1 6.2 Communication alarm reset . 6-2 6.3 Setting and checking . 6-2 6.3.1 Setting and checking items . 6-2 HRS090 Series HRX-OM-T004 Contents
-A-20/40HRSH150-W-20/4025 25 Facility water temperature 32C Ambient temperature 32C 20 20 Cooling capacity [kW] Cooling capacity [kW] 15.7 15.7 15 15 Ambient temperature 43C 10 10 Facility water temperature 40C Ambient temperature 45C 5 5 0 0 5 10 15 20 25 30 35 5 10 15 20 25 30 35 Circulating fluid temperature [C] Circulating fluid temperature [C] HRSH200-A-20/40HRSH200-W-20/4030 30 Ambient
Pump Capacity HRS100/150-Am-20/40-m HRS100/150-Wm-20/40-m 0.5 50 Circulating fluid pressure [MPa] HRS Circulating fluid outlet (60 Hz) Usable range (50 Hz) 0.4 40 HRS 090 Pump head [m] 0.3 30 Usable range (60 Hz) HRS 100/150 HRS 100/150 Circulating fluid outlet (50 Hz) 0.2 20 HRSH 090 Circulating fluid return port 0.1 10 HRSH 0 0 0 10 20 30 40 50 60 70 HRSE Circulating fluid flow rate [L
Q = m x C x (T0 Tt) it = r x V x C x iT it = 1 x 20 x 4.2 x 103 x 12 900 = 1120 [J/s] 1120 [W] Q = m x C x (T0 Tt) it x 860 = c x V x 60 x C x iT it x 860 Cooling capacity = Considering a safety factor of 20%, 1120 [W] x 1.2 = 1344 [W] = 1 x 20 x 60 x 1.0 x 103 x 12 Thermo-chiller Q x t: Heat capacity [kJ] 15 x 860 1120 [W] 20C Water bath Cooling capacity = Considering a safety factor
Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: Rc, Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: M (Applicable to Deionized Water Piping)
Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: M (Applicable to Deionized Water Piping)
Cooling Method: W (Water-cooled Refrigeration), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: M (Applicable to Deionized Water Piping)
Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: F [G (w/Rc-G Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: M (Applicable to Deionized Water Piping)
Cooling Method: Air-cooled Refrigeration, Pipe Thread: Rc, Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: Applicable to Deionized Water Piping
Cooling Method: Air-cooled Refrigeration, Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: Applicable to Deionized Water Piping
Cooling Method: Water-cooled Refrigeration, Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: Applicable to Deionized Water Piping
Cooling Method: Air-cooled Refrigeration, Pipe Thread: F [G (w/Rc-G Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: Applicable to Deionized Water Piping
Cooling Method: W (Water-cooled Refrigeration), Pipe Thread: F [G (w/Rc-G Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: M (Applicable to Deionized Water Piping)
Thermo-chiller HRS offers convenient functions, self diagnosis and check display for easy maintenance. An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values. The dustproof filter is integrated with the grill of the front panel allowing mounting and removal of the HRS filter
Thermo-chiller HRS offers convenient functions, self diagnosis and check display for easy maintenance. An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values. The dustproof filter is integrated with the grill of the front panel allowing mounting and removal of the HRS filter
Cooling Method: W (Water-cooled Refrigeration), Pipe Thread: Rc, Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz]
Cooling Capacity: 9 kW, Piping thread type: Rc, Optional specifications: None
Thermo-chiller HRS offers convenient functions, self diagnosis and check display for easy maintenance. An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values. The dustproof filter is integrated with the grill of the front panel allowing mounting and removal of the HRS filter