SMC Corporation of America
Elite Part Number Search
Search Results "HRS150-AN-46-K"

)-B/AR25(K)-B t e q IN OUT t Modular F.R.L. e q r IN OUT w r w AC-A AC-B AR30(K)-B/AR40(K)-B q t AR50(K)-B/AR60(K)-B e IN OUT q t r w e IN OUT r w Component Parts No.

This information is needed when contacting an SMC sales distributor. An example of HRS150-A-20 "3~" stands for "3 interphase".

(mm) CK1 Bore size A B C D F FB FC FT FX FY FZ GA H MM NA NB NN T S Z 5 to 15 st 16 to 30 st 31 to 45 st 46 to 60 st 61 to 75 st 76 to 101 to 126 to 150 st 5 to 15 st 16 to 30 st 31 to 45 st 46 to 60 st 61 to 75 st 76 to 101 to 126 to C(L)K 100 st 125 st 100 st 125 st 150 st 6 15 12 14 3 8 13 4.5 1.6 24 14 32 14.5 28 M3 x 0.5 16 3 M6 x 1.0 3 46.5 55.5 59.5 73.5 (78.5) 74.5 (79.5) 83.5 (88.5

The combination of K, L and M is not possible because an auto drain can only be attached to a single option. *2 The maximum operating pressure is 1.6 MPa. *3 Voltage symbol 20 (200 VAC) is the terminal block connection as standard. The Option S cannot be chosen.

415 VAC (50/60 Hz) 20 A M5 4 cores x 5.5 mm2 (4 cores x AWG10) (Including grounding cable R5.5-5) R5.5-5 HRS150-Al-40-l HRS150-Wl-40-l Note) An example of the cable specifications is when two kinds of vinyl insulated wires with a continuous allowable operating temperature of 70C at 600 V, are used at an ambient temperature of 30C.

Cooling Capacity: 150, Thread Type: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)]

Cooling Capacity: 150, Thread Type: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], Option 1: -, UL Certification: -, Option 2: -

Cooling Capacity: 150, Thread Type: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], Option 1: AK (A + K)

Cooling Capacity: 150, Thread Type: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], Option 1: A + K, UL Certification: -, Option 2: -

Cooling Capacity: 150, Thread Type: Rc, Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], Option 1: K (w/Fluid Fill Port)

Cooling Capacity: 150, Thread Type: F [G (w/Rc-G Conversion Fitting)], Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], Option 1: K (w/Fluid Fill Port)

Cooling Capacity: 150, Thread Type: Rc, Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], Option 1: w/Fluid Fill Port, UL Certification: -, Option 2: -

Cooling Capacity: 150, Thread Type: F [G (w/Rc-G Conversion Fitting)], Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], Option 1: w/Fluid Fill Port, UL Certification: -, Option 2: -

K E When ordering an oversized rod, please order the following way to represent the rod size required.

/Flange Rod end width across flats 10 10 21 21 46 46 Data Part no.