Your search for HY returned 16 result(s)
There were no hits with the full part number, but there were 9 hits in the keyword search.
There were no hits with the full part number, but there were 63 hits in the keyword search.
Product Information » New Products Search Results
Built-in Magnet: None, Bore Size: 50mm, Thread: Rc (M5x0.8), Seal: H (External: FKM), Stroke: 100mm, Grease: F (Grease Approved for Food Industry), Rod End: M (Male Thread)
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): 0~60, End Locking: No, Valves: No, Operating Pressure(MPa): 0.15~1, Port thread type: Rc, Auto Switches: Without auto switch
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): 0~60, End Locking: No, Valves: No, Operating Pressure(MPa): 0.15~1, Port thread type: Rc, Auto Switches: Without auto switch
Production and packaging applications involving food and beverages often need specialized equipment to meet the strict hygiene standards required in these industry sectors.? SMC, the world leader in pneumatic technology, has developed the HY series to meet these requirements.? All the models in the HY series are particularly suitable for application in the "non-food" or "splash" zones of
1/2 26 (45) 25 (43) 28 (47) 43 (74) 41 (70) 45 (77) NPT 3/4 R134a (HFC) 100F (37.8C) 100 psi (0.7 MPa) 62 (106) 59 (100) 65 (110) P. 90 to 96 80 (136) 71 (120) 86 (147) NPT 1 120 (205) 107 (182) 130 (221) NPT 11/2 173 (294) 161 (273) 181 (308) R407C (HFC) 258 (438) 226 (384) 297 (504) NPT 2 353 (600) 300 (510) 406 (690) Note) Air flow capacity for each dew point is indicated. 2.
IDFA 100F 40 For use in Europe Nil C G K R V Size Size 100F 125F 150F Option Voltage Symbol Note) Description Symbol Voltage Nil C G K R V None Three-phase 400 VAC (50 Hz) 40 Anti-corrosive treatment for copper tube With Chinese labels and a Chinese operation manual Moderate pressure specification (1.6 MPa) With a circuit breaker With a timer controlled solenoid valve type auto drain Note
Refrigerant R134a (HFC) IDU E IDF 100F 30 W Water-cooled Nil C G K P R V 4 5 Size Size Air compressor size *1 Piping direction 100F 100 kW 125F 125 kW 150F 150 kW Symbol Description 4 Facility water piping direction: Right *1 Refrigerant R407C (HFC) IDU E 5 Facility water piping direction: Left *1 *1 Note that the above values are for reference only.
.: GR-S-010 (10 g) HYQB50H-PS Place the seal material symbol in . Place the seal material symbol in . Place the seal material symbol in . HYQB63H-PS Material Symbol Material Symbol Material Symbol Place the seal material symbol in . Place the seal material symbol in . Place the seal material symbol in .
(37.8C) 100 psi (0.7 MPa) 100F (37.8C) IDFB80 247 (420) 314 (534) 353 (600) R2/ NPT2 IDFB90 335 (570) 406 (690) 459 (780) *1 Select port sizes when ordering the products.
Heatless Desiccant Compressed Air Dryers Series IDW Features -40F dew point standard, -100F optional Suitable for global installation 12~24VDC or 100~240VAC Vertical or horizontal mounting Designed for simple service with desiccant canisters Intelligent electronic processor Specifications Inlet flow rate Dimension inch Weight (lbs) Dryer configuration Dryer model Pipe size B C A scfm
0.1) (10) Q : Flow rate [kg/h] Kv : Flow coefficient [m3/h] P : Pressure difference [MPa] P1 : Upstream pressure [MPa]: P = P1 P2 P2 : Downstream pressure [MPa] 160 Solenoid Valve Flow Rate Characteristics VXD Series Conversion of flow coefficient: Kv = 0.865 Cv (11) VX2 Here, Cv factor: Value of the clean water flow rate represented by US gal/min that runs through the valve at 40 to 100F
0.1) (10) Q : Flow rate [kg/h] Kv : Flow coefficient [m3/h] P : Pressure difference [MPa] P1 : Upstream pressure [MPa]: P = P1 P2 P2 : Downstream pressure [MPa] 230 Solenoid Valve Flow Rate Characteristics VXS Series Conversion of flow coefficient: Kv = 0.865 Cv (11) VX2 Here, Cv factor: Value of the clean water flow rate represented by US gal/min that runs through the valve at 40 to 100F
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com BT-04 BT-04 BT-06 BT-08 BT-08 Calculation: (Example) CA2LQ40-100F (Axial foot style, 40, 100 st) Basic weight . 1.08kg Additional weight . 0.22/50 st D-A3/A44 Cylinder stroke . 100 st BD1-04M BD1-05M BD1-06M BD1-08M BD1-10M D-G39/K39 1.08 + 0.22
Additional weight with magnet. .0.02 0.12 + 0.05 x 100/50 + 0.022 + 0.02 = 0.262 kg Calculation: (Example) JCMBZ25TR-100F Basic weight.0.10 (Basic (Female thread on rod cover), Rc1/8 port, 25) Additional weight.0.05/50 mm stroke Cylinder stroke.100 mm stroke 0.10 + 0.05 x 100/50 = 0.20 kg Allowable Kinetic Energy Allowable Lateral Load at Rod End fR Table (1) Max.
coefficient [m3/h] DP : Pressure difference [MPa] P1 : Upstream pressure [MPa]: DP = P1 P2 P2 : Downstream pressure [MPa] 57 Solenoid Valve Flow Rate Characteristics JSX/JSXm Series Flow Rate Characteristics JSX Series Conversion of flow coefficient: Kv = 0.865 Cv (11) Here, Cv factor: Value of the clean water flow rate (represented by US gal/min) which runs through a valve at 40 to 100F