www.stevenengineering.com I 2.e VALVES Z VALVE SERIES OVERVIEW ZValve F a m i l y SMC P n e u m a t i c s h a s a g a i n c o n f i r m e d i t s t e c h n o l o g i c a l l e a d e r s h i p i n t h e w o r l d pneumatics market with the release of the Z valve series.
T h e V YH y R e g R a n g e i s c o n s t r u c t e d b y u t i l i z i n g a standard control unit either alone (VY1D00-M5) or as a Pilot Valve controlling one of the Range of VEX1 Power Valves.
Series IR Precision Regulators are designed to be compact and light weight. The maximum set pressure has been expanded from the conventional 0.7MPa to 0.8MPa. Relief flow has been increased by nearly 5 times (compared to SMC IR201, IR401). The optio, Y, IR, "REGULATOR, N lb
Body Size: 1, Set Pressure: 2 (1.5 to 116 psi [0.01 to 0.8 MPa]), Exhaust Direction: 0 (Bottom Exhaust), Thread: N (NPT), Port Size: 01 (1/8), Option: BEC (w/Bracket + NPN Open Collector, 1 Output + Analog Voltage Output), Semi-standard: ZA (Digital Pressure Switch: With Unit Conversion Function)
Regulator, Pressure Boosting Valve: Regulator, Regulator Type: Precision Control, Shape: Standard, Operating Environment: Standard, Compatible Fluid: Air, Exhaust Mechanism (Air Bleed): [Included] Relief, Reverse Flow Function (Relief): No, Supply Side Connection Type: [NPT] NPT, Supply Side, Connection Diameter: 1/8, Flow Direction: [Right] From Left to Right, Control Side Connection Type
Fluororubber is used for rubber seal materials. 80 IR 0 Ozone resistant X170 IR 0 Compatible with modular connection brackets Modular Combination Example Description Applicable model IR100--X170 AF20-A AFM20-A Y200-A Y200T-A IR20--X170 AF30-A AFM30-A Y300-A Y300T-A IR30--X170 AF40-A AFM40-A Y400-A Y400T-A qRegulator wAir filter eMist separator rInterface tInterface with bracket Note 1) The
When a system hazard can be expected due to a drop in vacuum pressure caused by power loss or vacuum pump trouble, install a safety circuit and configure the system so that it can avoid the danger. 2. When a system hazard can be expected with a malfunction of the vacuum regulator, install a safety circuit and configure the system so that it can avoid the danger. 1.
If a directional switching valve (solenoid valve, mechanical valve, etc.) is mounted on the supply side of the regulator and repeatedly switched ON and OFF, wear of the nozzle/flapper section will be accelerated and a discrepancy in the setting value may occur. Therefore, avoid using a directional switching valve on the supply side.
(Normally closed) A N.O.
(IR1000:F.S.=0.2MPa,IR1010:F.S.=0.4MPa,IR1020:F.S.=0.8MPa) ) F.S. (2) (3) (4) 0.010.8MPa(IR1000 0.005MPa) 1 IR1000 IR1010 IR1020 [MPa] MAX. 1.0 [MPa] () 0.05 [MPa] 0.0050.2 0.010.4 0.010.8 0.2% 0.5% 4.4L/min(ANR) [1.0MPa ] -560 Rc1/8 Rc1/8 [2 ] 0.14kg (1) (0.05MPa) (2) IR1000:0.2MPa (3)2 ON-OFF () (4) -4- (C)2 (C) (A) (A) (C) (A) (C) BLEED SUP(1) OUT(2) SUP N
Body Size: 1, Set Pressure: 0.02 to 0.4 MPa, Exhaust Direction: Bottom Exhaust, Thread: NPT, Port Size: 1/8, Option: B + EC, Semi-standard: Name Plate & Pressure Gauge in Imperial Units: psi
Body Size: 1, Set Pressure: 1 (0.02 to 0.4 MPa), Exhaust Direction: 0 (Bottom Exhaust), Thread: N (NPT), Port Size: 01 (1/8), Option: BEC (B + EC), Semi-standard: Z (Name Plate & Pressure Gauge in Imperial Units: psi)
Body Size: 1, Set Pressure: 1.5 to 116 psi [0.01 to 0.8 MPa], Exhaust Direction: Bottom Exhaust, Thread: NPT, Port Size: 1/8, Option: w/Bracket + PNP Open Collector, 1 Output, Semi-standard: Name Plate & Pressure Gauge in Imperial Units: psi
Body Size: 1, Set Pressure: 1.5 to 116 psi [0.01 to 0.8 MPa], Exhaust Direction: Bottom Exhaust, Thread: NPT, Port Size: 1/8, Option: NPN Open Collector, 1 Output, Semi-standard: Name Plate & Pressure Gauge in Imperial Units: psi
Body Size: 1, Set Pressure: 1.5 to 116 psi [0.01 to 0.8 MPa], Exhaust Direction: Bottom Exhaust, Thread: NPT, Port Size: 1/8, Option: Round Type Pressure Gauge + w/Hexagon Panel Nut, for Panel Mount, Semi-standard: Name Plate & Pressure Gauge in Imperial Units: psi
Body Size: 1, Set Pressure: 1.5 to 116 psi [0.01 to 0.8 MPa], Exhaust Direction: Bottom Exhaust, Thread: NPT, Port Size: 1/8, Option: w/Hexagon Panel Nut, for Panel Mount, Semi-standard: Name Plate & Pressure Gauge in Imperial Units: psi
Body Size: 1, Set Pressure: 1.5 to 116 psi [0.01 to 0.8 MPa], Exhaust Direction: Bottom Exhaust, Thread: NPT, Port Size: 1/8, Option: Round Type Pressure Gauge, Semi-standard: Name Plate & Pressure Gauge in Imperial Units: psi
Body Size: 1, Set Pressure: 1.5 to 116 psi [0.01 to 0.8 MPa], Exhaust Direction: Bottom Exhaust, Thread: NPT, Port Size: 1/8, Option: w/Bracket + NPN Open Collector, 1 Output, Semi-standard: Name Plate & Pressure Gauge in Imperial Units: psi
Body Size: 1, Set Pressure: 1.5 to 116 psi [0.01 to 0.8 MPa], Exhaust Direction: Bottom Exhaust, Thread: NPT, Port Size: 1/8, Option: PNP Open Collector, 1 Output, Semi-standard: Name Plate & Pressure Gauge in Imperial Units: psi
Body Size: 1, Set Pressure: 2 (1.5 to 116 psi [0.01 to 0.8 MPa]), Exhaust Direction: 0 (Bottom Exhaust), Thread: N (NPT), Port Size: 01 (1/8), Option: BEB (w/Bracket + PNP Open Collector, 1 Output), Semi-standard: Z (Name Plate & Pressure Gauge in Imperial Units: psi)