SMC Corporation of America
Elite Part Number Search
Search Results "IR2010-N02BEA-Z-A"

Fluororubber is used for rubber seal materials. 80 IR 0 Ozone resistant X170 IR 0 Compatible with modular connection brackets Modular Combination Example Description Applicable model IR100--X170 AF20-A AFM20-A Y200-A Y200T-A IR20--X170 AF30-A AFM30-A Y300-A Y300T-A IR30--X170 AF40-A AFM40-A Y400-A Y400T-A qRegulator wAir filter eMist separator rInterface tInterface with bracket Note 1) The

When a system hazard can be expected due to a drop in vacuum pressure caused by power loss or vacuum pump trouble, install a safety circuit and configure the system so that it can avoid the danger. 2. When a system hazard can be expected with a malfunction of the vacuum regulator, install a safety circuit and configure the system so that it can avoid the danger. 1.

If a directional switching valve (solenoid valve, mechanical valve, etc.) is mounted on the supply side of the regulator and repeatedly switched ON and OFF, wear of the nozzle/flapper section will be accelerated and a discrepancy in the setting value may occur. Therefore, avoid using a directional switching valve on the supply side.

www.stevenengineering.com I 2.e VALVES Z VALVE SERIES OVERVIEW ZValve F a m i l y SMC P n e u m a t i c s h a s a g a i n c o n f i r m e d i t s t e c h n o l o g i c a l l e a d e r s h i p i n t h e w o r l d pneumatics market with the release of the Z valve series.

T h e V YH y R e g R a n g e i s c o n s t r u c t e d b y u t i l i z i n g a standard control unit either alone (VY1D00-M5) or as a Pilot Valve controlling one of the Range of VEX1 Power Valves.

(B),2 (C),(B)(A), () (B)(C) (A) BLEED (B) (C) OUT SUP SUP. 1 1 M Pa/ m ( B) m 2 N / m m m M Pa M Pa/ m m M Pa B m /N (A) ) ( N N m / N ( C) m 2 N ( A) m 2 N -5- 3. 1 SUP OUT 2 %F.S 3 4 R B(P36202028) G 2 3 Rc,F N IR2000G43-2-01 G43-P2-N01-X30 IR2010G43-4-01 G43-P4-N01-X30 IR2020G43-10-01 G43-P10-N01-X30 021/44 Rc NNPT FG 00.0050.2MPa 1: 0.010.4MPa 20.010.8MPa

Double acting PA PA B A PB B A With by-pass Suck back valve Manual Operation-Series LVH N.C. Double acting P PA PA Locking and non-locking types available B A B A PB B A Integral fitting type/Threaded type Manifolds Main applications and fields For shut off For air bleeding N.C.


For the IR200-02□□: IR2000-02□□-A
For the IR201-02□□: IR2010-02□□-A
For the IR202-02□□: IR2020-02□□-A
Note) Select option “H” when panel mounting the product.
The panel mounting hole dimensions are the same for old IR200 and IR2000-A series regulators.

Body Size: 2, Set Pressure: Body Size 1, 2: 0.73 to 29 psi [0.005 to 0.2 MPa]; Body Size 3: 1.5 to 29 psi [0.01 to 0.2 MPa], Exhaust Direction: Bottom Exhaust, Thread: NPT, Port Size: 1/4, Option: w/Bracket + NPN Open Collector, 1 Output, Semi-standard: Name Plate & Pressure Gauge in Imperial Units: psi

Body Size: 2, Set Pressure: 1.5 to 116 psi [0.01 to 0.8 MPa], Exhaust Direction: Bottom Exhaust, Thread: NPT, Port Size: 1/4, Option: w/Bracket + NPN Open Collector, 1 Output, Semi-standard: Name Plate & Pressure Gauge in Imperial Units: psi

Body Size: 2, Set Pressure: 0 (Body Size 1, 2: 0.73 to 29 psi [0.005 to 0.2 MPa]; Body Size 3: 1.5 to 29 psi [0.01 to 0.2 MPa]), Exhaust Direction: 0 (Bottom Exhaust), Thread: N (NPT), Port Size: 02 (1/4), Option: BEA (w/Bracket + NPN Open Collector, 1 Output), Semi-standard: Z (Name Plate & Pressure Gauge in Imperial Units: psi)

Body Size: 2, Set Pressure: 2 (1.5 to 116 psi [0.01 to 0.8 MPa]), Exhaust Direction: 0 (Bottom Exhaust), Thread: N (NPT), Port Size: 02 (1/4), Option: BEA (w/Bracket + NPN Open Collector, 1 Output), Semi-standard: Z (Name Plate & Pressure Gauge in Imperial Units: psi)

Body Size: 2, Set Pressure: 1.5 to 116 psi [0.01 to 0.8 MPa], Exhaust Direction: Bottom Exhaust, Thread: NPT, Port Size: 1/4, Option: w/Bracket + NPN Open Collector, 1 Output, Semi-standard: Flow Direction: Right to Left + Downward + Digital Pressure Switch: With Unit Conversion Function

Body Size: 2, Set Pressure: 2 (1.5 to 116 psi [0.01 to 0.8 MPa]), Exhaust Direction: 0 (Bottom Exhaust), Thread: N (NPT), Port Size: 02 (1/4), Option: BEA (w/Bracket + NPN Open Collector, 1 Output), Semi-standard: RVZA (Flow Direction: Right to Left + Downward + Digital Pressure Switch: With Unit Conversion Function)

Body Size: 2, Set Pressure: 1.5 to 58 psi [0.01 to 0.4 MPa], Exhaust Direction: Bottom Exhaust, Thread: NPT, Port Size: 1/4, Option: w/Bracket + PNP Open Collector, 1 Output, Semi-standard: Name Plate & Pressure Gauge in Imperial Units: psi

Body Size: 2, Set Pressure: 1.5 to 58 psi [0.01 to 0.4 MPa], Exhaust Direction: Bottom Exhaust, Thread: NPT, Port Size: 1/4, Option: w/Bracket + NPN Open Collector, 1 Output + Analog Voltage Output, Semi-standard: Name Plate & Pressure Gauge in Imperial Units: psi

Body Size: 2, Set Pressure: 1.5 to 58 psi [0.01 to 0.4 MPa], Exhaust Direction: Bottom Exhaust, Thread: NPT, Port Size: 1/4, Option: NPN Open Collector, 1 Output + Analog Voltage Output, Semi-standard: Name Plate & Pressure Gauge in Imperial Units: psi

Body Size: 2, Set Pressure: 1.5 to 58 psi [0.01 to 0.4 MPa], Exhaust Direction: Bottom Exhaust, Thread: NPT, Port Size: 1/4, Option: NPN Open Collector, 1 Output, Semi-standard: Name Plate & Pressure Gauge in Imperial Units: psi

Body Size: 2, Set Pressure: 1.5 to 58 psi [0.01 to 0.4 MPa], Exhaust Direction: Bottom Exhaust, Thread: NPT, Port Size: 1/4, Option: PNP Open Collector, 1 Output, Semi-standard: Name Plate & Pressure Gauge in Imperial Units: psi