Your search for ISE10 returned 30 result(s)
There were no hits with the full part number, but there were 67 hits in the keyword search.
There were no hits with the full part number, but there were 1 hits in the keyword search.
Product Information » New Products Search Results
Option -L Port combination: Individual PV Common PS = Common PD Port layout No. 17 Circuit example Single unit: ZK2ClR KlllA-l-L Manifold: ZZK2lA-A1l-L PV PV EXH EXH Common PS Common PS Common PD Common PD Common PS Common PV Common PS Common PV (= Common PD) (= Common PD) Individual PV Common EXH Common EXH (including PE) (including PE) V EXH2 EXH2 1 The complex exhaust is a combined exhaust
Piping Specifications: M5R (M5 Female Thread/Rear Piping Port), Output Specifications: B (PNP Open Collector 2 Outputs), Unit Specifications: P (Unit Switching Function, Initial Value psi, Not Allowed for Use in Japan), Lead Wire: No Lead Wire, Adapter: D (Panel Mount Adapter+Front Protective Cover)
Piping Specifications: M5R (M5 Female Thread/Rear Piping Port), Output Specifications: E (PNP Open Collector 1 Output+Analog Voltage), Unit Specifications: P (Unit Switching Function, Initial Value psi, Not Allowed for Use in Japan), Lead Wire: No Lead Wire, Adapter: D (Panel Mount Adapter+Front Protective Cover)
Piping Specifications: M5R (M5 Female Thread/Rear Piping Port), Output Specifications: C (NPN Open Collector 1 Output+Analog Voltage), Unit Specifications: P (Unit Switching Function, Initial Value psi, Not Allowed for Use in Japan), Lead Wire: No Lead Wire, Adapter: D (Panel Mount Adapter+Front Protective Cover)
Piping Specifications: M5 Female Thread/Rear Piping Port, Output Specifications: PNP Open Collector 2 Outputs, Unit Specifications: Unit Switching Function, Initial Value psi, Not Allowed for Use in Japan, Lead Wire: No Lead Wire, Adapter: Panel Mount Adapter+Front Protective Cover, Calibration Certification: -
Piping Specifications: M5 Female Thread/Rear Piping Port, Output Specifications: PNP Open Collector 1 Output+Analog Voltage, Unit Specifications: Unit Switching Function, Initial Value psi, Not Allowed for Use in Japan, Lead Wire: No Lead Wire, Adapter: Panel Mount Adapter+Front Protective Cover, Calibration Certification: -
Piping Specifications: M5 Female Thread/Rear Piping Port, Output Specifications: NPN Open Collector 1 Output+Analog Voltage, Unit Specifications: Unit Switching Function, Initial Value psi, Not Allowed for Use in Japan, Lead Wire: No Lead Wire, Adapter: Panel Mount Adapter+Front Protective Cover, Calibration Certification: -
Manifold overall length Manifold overall length Approx. 29% reduced SY5000 manifold SY5000 3 stations SY3000 manifold SY3000 4 stations Mixed manifold SY5000 3 stations SY3000 4 stations For serial transmission EX260 A B A B A B A B A B A B A B A B A B A 14 A B A 14 A B A 14 A B A 14 A B A 14 A B A 14 Installation space A A A A A A A A B B B B B B B B 12 B 12 B 12 B 12 B 12 B 12 B 136.7 mm
Piping Specifications: M5R (M5 Female Thread/Rear Piping Port), Output Specifications: A (NPN Open Collector 2 Outputs), Unit Specifications: P (Unit Switching Function, Initial Value psi, Not Allowed for Use in Japan), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover], Adapter: D (Panel Mount Adapter+Front Protective Cover), Calibration Certification: K (w/Certificate
Piping Specifications: M5R (M5 Female Thread/Rear Piping Port), Output Specifications: A (NPN Open Collector 2 Outputs), Unit Specifications: M (Fixed SI Unit, kPa), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover], Adapter: D (Panel Mount Adapter+Front Protective Cover)
Piping Specifications: M5R (M5 Female Thread/Rear Piping Port), Output Specifications: A (NPN Open Collector 2 Outputs), Unit Specifications: Unit Switching Function (Not Allowed for Use in Japan), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover], Adapter: D (Panel Mount Adapter+Front Protective Cover)
Piping Specifications: M5R (M5 Female Thread/Rear Piping Port), Output Specifications: A (NPN Open Collector 2 Outputs), Unit Specifications: P (Unit Switching Function, Initial Value psi, Not Allowed for Use in Japan), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover], Adapter: D (Panel Mount Adapter+Front Protective Cover)
Piping Specifications: M5R (M5 Female Thread/Rear Piping Port), Output Specifications: A (NPN Open Collector 2 Outputs), Unit Specifications: P (Unit Switching Function, Initial Value psi, Not Allowed for Use in Japan)
Piping Specifications: M5R (M5 Female Thread/Rear Piping Port), Output Specifications: A (NPN Open Collector 2 Outputs), Unit Specifications: Unit Switching Function (Not Allowed for Use in Japan), Lead Wire: No Lead Wire, Adapter: D (Panel Mount Adapter+Front Protective Cover)
Piping Specifications: M5R (M5 Female Thread/Rear Piping Port), Output Specifications: A (NPN Open Collector 2 Outputs), Unit Specifications: P (Unit Switching Function, Initial Value psi, Not Allowed for Use in Japan), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover]
Type: Pressure Switch, Fluid Type: Air, Sensor, Monitor Structure: [Integrated Type] Integrated shape, Analog Output Specification: -, Pipe Port Type: Female Thread, Plumbing Thread Type: M, Plumbing Thread Nominal: M5x0.8, Fluid Characteristics: Noncorrosive / Incombustible, Pressure Resistance(MPa): 1.5, Operating Temperature Range(°C): -5~50, Operating Humidity Range(%): 35~85, Number