High-Precision Digital Pressure Switch ZSE20(F)/ISE20 Series How to Order p. 9 Specifications p. 10 Set Pressure Range and Rated Pressure Range p. 17 Analog Output p. 17 IO-Link: Process Data p. 17 Functions p. 17 Internal Circuits and Wiring Examples p. 18 Dimensions p. 20 3-Screen Display High-Precision Digital Pressure Switch ZSE20A(F)/ISE20A Series How to Order p. 11 Specifications p
-100.0~100.0 kPa T 2 X NPN2 Y PNP2 R NPN2+1 T PNP2+1 A1 A S NPN2+1 V PNP2+1 1: A2 B M SI3 P psi2 2 3 kPaMpa B D + M5 M5 1 01 R1/8 N01 NPT1/8 C4H 4mm J (2m) C6H 6mm N7H 1/4 inch C4L 4mm C6L 6mm N7L 1/4 inch -8No.PS-OMU0002CN-D / A ZS-46-A1 38L(2 ) B ZS-46-A2 38L(2 ) ZS-46-B + ZS-46-D ZS-46-5L 5 2m ZS-27-01 R1/8 ZS-46-N1 NPT1/8 ZS-46-N2 4mm ZS-46-C4H 6mm ZS-46-C6H 1/4 inch
This is a legacy product, and replaced byISE20A-Y-N01-JA1-X505 ISE30/ISE30A PRESSURE SWITCH. SWITCH ASSEMBLY. INSTRUMENTATION. ISE30 1/8 INCH NPT VERSION. 0.27469 lb. CB.
Bracket B MPa ISE20A ISE20A: 0.050 MPa/ZSE20A: 5.1 kPa/ ZSE20AF: 5.0 kPa "Nil" or M Hysteresis kPa ZSE20A(F) Safety Instructions ISE20A Delay time 1.5 ms or less Mounting with panel mount adapter Mount part (a) to the front of the body and fix it. Then insert the body with (a) into the panel until (a) comes into contact with the panel front surface.
This is a legacy product, and replaced byZSE20AF-V-M-N01-JA1 ZSE30 VACUUM SWITCH. SWITCH ASSEMBLY. VACUUM SERIES. ZSE30 1/8 PORTED. .14109 lb. JD.
Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: NPT 1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Bracket: Bracket A, Vertical Mounting, Operation Manual: -
Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: A1 (Bracket A, Vertical Mounting)
Controller Mounting: S (Screw Mounting), Cable Length: 1 (1 m), Inlet Port Silencer: B (ANB1-01, 55 dB), Digital Pressure Switch: P (ISE20A-Y-01-J-X603)
Controller Mounting: S (Screw Mounting), Cable Length: 1 (1 m), Inlet Port Silencer: B (ANB1-01, 55 dB), Digital Pressure Switch: P (ISE20A-Y-01-J-X603), Exhaust Check Valve: K (AKH06-00, for 6mm tubing), Exhaust Solenoid Valve: V (V124-5LU-M5)
Controller Mounting: D (DIN Rail Mouting), Cable Length: 1 (1 m), Inlet Port Silencer: B (ANB1-01, 55 dB), Digital Pressure Switch: P (ISE20A-Y-01-J-X603), Exhaust Check Valve: K (AKH06-00, for 6mm tubing), Exhaust Solenoid Valve: V (V124-5LU-M5)
Controller Mounting: S (Screw Mounting), Cable Length: 1 (1 m), Inlet Port Silencer: (None 75 dB), Digital Pressure Switch: P (ISE20A-Y-01-J-X603), Exhaust Check Valve: K (AKH06-00, for 6mm tubing), Exhaust Solenoid Valve: V (V124-5LU-M5)
Controller Mounting: S (Screw Mounting), Cable Length: 1 (1 m), Inlet Port Silencer: B (ANB1-01, 55 dB), Digital Pressure Switch: P (ISE20A-Y-01-J-X603), Exhaust Check Valve: (None), Exhaust Solenoid Valve: V (V124-5LU-M5)
Controller Mounting: S (Screw Mounting), Cable Length: 1 (1 m), Inlet Port Silencer: A (AN10-01, 62 dB), Digital Pressure Switch: P (ISE20A-Y-01-J-X603), Exhaust Check Valve: K (AKH06-00, for 6mm tubing)
Controller Mounting: S (Screw Mounting), Cable Length: 1 (1 m), Inlet Port Silencer: A (AN10-01, 62 dB), Digital Pressure Switch: P (ISE20A-Y-01-J-X603), Exhaust Check Valve: (None), Exhaust Solenoid Valve: V (V124-5LU-M5)
Controller Mounting: S (Screw Mounting), Cable Length: 1 (1 m), Inlet Port Silencer: (None 75 dB), Digital Pressure Switch: P (ISE20A-Y-01-J-X603)
Controller Mounting: D (DIN Rail Mouting), Cable Length: 1 (1 m), Inlet Port Silencer: B (ANB1-01, 55 dB), Digital Pressure Switch: P (ISE20A-Y-01-J-X603)
Controller Mounting: D (DIN Rail Mouting), Cable Length: 1 (1 m), Inlet Port Silencer: (None 75 dB), Digital Pressure Switch: P (ISE20A-Y-01-J-X603), Exhaust Check Valve: K (AKH06-00, for 6mm tubing), Exhaust Solenoid Valve: V (V124-5LU-M5)
Controller Mounting: S (Screw Mounting), Cable Length: 1 (1 m), Inlet Port Silencer: A (AN10-01, 62 dB), Digital Pressure Switch: P (ISE20A-Y-01-J-X603)
Controller Mounting: D (DIN Rail Mouting), Cable Length: 1 (1 m), Inlet Port Silencer: A (AN10-01, 62 dB), Digital Pressure Switch: P (ISE20A-Y-01-J-X603), Exhaust Check Valve: K (AKH06-00, for 6mm tubing), Exhaust Solenoid Valve: V (V124-5LU-M5)
Controller Mounting: S (Screw Mounting), Cable Length: 1 (1 m), Inlet Port Silencer: B (ANB1-01, 55 dB), Digital Pressure Switch: P (ISE20A-Y-01-J-X603), Exhaust Check Valve: K (AKH06-00, for 6mm tubing)