SMC Corporation of America
Elite Part Number Search
Search Results "ISE20B-L-N01-WB"

Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: Unit Selection Function, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: B [Panel Mount Adapter, (ZS-46-B)], Operation Manual: Y (w/o Operation Manual, w/o Calibration Certificate)

The ISE2 series is a compact, pressure switch (for positive pressure) and can be integrated with ZX or ZR vacuum systems. The ISE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple. PRESSURE SWITCH, ISE1-6. 3 SCREEN HI PRECISION DIG PRESS SWITCH. 73.00000 lb. N59.

Specifications/IO-Link Compatible Model ZSE20B-L (Vacuum pressure) ZSE20BF-L (Compound pressure) ISE20B-L (Positive pressure) Applicable fluid Air, Non-corrosive gas, Non-flammable gas ZSE20C(F)/ISE20C(H) ZSE20B(F)/ISE20B ZSE20B(F)-L/ISE20B-L ZSE20A(F)/ISE20A ZSE20(F)/ISE20 Function Details Made to Order Rated pressure range 0.0 to 100.0 kPa 100.0 to 100.0 kPa 0.000 to 1.000 MPa Display/Set

Normal output ISE20B : 0.500 MPa Pressure setting Sets the ON and OFF point of the switch output. ZSE20B : -50.5 kPa ZSE20BF : 50.0 kPa ISE20B : 0.050 MPa Hysteresis Appropriate setting of the hysteresis will prevent the switch output from chattering.

Before Use Digital Pressure Switch ZSE20B(F)-L/ISE20B-L Mounting and Installation Outline of Settings [Measurement mode] Function Selection Mode Installation Mounting Mount the optional bracket and panel mount adapter to the pressure switch.

H E R M A N I F O L D O P T I O N S : L A T C H I N G S O L E N O I D T Y P E L A T C H I N G T Y P E V A L V E L A T C H I N G T Y P E V A L V E W I T H M A N U A L O V E R R I D E M A N I F O L D O P T I O N P A R T S A V A I L A B L E : P E R F E C T C H E C K B L O C K P E R F E C T C H E C K B L O C K W I T H V A L V E O R M A N I F O L D Courtesy of Steven Engineering, Inc. !

MPa ZSE20B(F) kPa P ISE20B psi ZSE20B(F) [F 1] OUT1 32 OFF ONOFF ISE20B 0.500 MPa ZSE20B -50.5 kPa ZSE20BF50.0 kPa ISE20B0.050 MPa ZSE20B 5.1 kPa ZSE20BF5.0 kPa 1.5ms OUT1 ON OUT1 OFF -29No.PS-OMU0005CN-C [F 2] OUT2 35 [F 1]OUT1 [F 3] 37 0 ms [F 4] 38 [F 5] FUNC 40 [F 6] 42 0% [F10] 43 std() [F11] 49 1000 [F80] 50 OFF [F81] 51 OFF [F82] 53 A [F90] 54 OFF [F96] 56 [F97

Luberetainer Bore size A B C CD CX CZ D GA GB H MM NA NB R U WA WB WW S Z ZZ 10 15 15 17 3.3 3.2 15 4 7.5 19.5 28 M4 x 0.7 21 31 5 8 14.4 26.5 45 63 99 104 16 15 18.3 20 5 6.5 18.3 5 7.5 24.5 28 M5 x 0.8 21 36 8 10 14.4 31.5 45 64 102 110 JA MXH Single Foot (L) MXQ CJ2ZL Bore size Stroke Head cover port location Z MGP CY CX CK1 C(L)K WB WA Rod end nut C(L)KU Mounting nut F GA Piping port

MPa ISE20B ISE20B: 0.050 MPa/ZSE20B: 5.1 kPa/ ZSE20BF: 5.0 kPa "Nil" or M Hysteresis kPa ZSE20B(F) Safety Instructions Bracket A ISE20B Delay time 1.5 ms or less Bracket B psi P ZSE20B(F) Display color OUT1 ON: Green/OUT1 OFF: Red : Arbitrary display These safety instructions are intended to prevent hazardous situations and/or equipment damage.

IO-Link Device Process Data (Example using the ISE20B-L) 24 8.6.3. IO-Link Device Identification (Example using the ISE20B-L) 24 8.6.4. IO-Link Device Observation (Example using the ISE20B-L) 25 8.6.5. IO-Link Device Parameter (Example using the ISE20B-L) 26 8.6.6. IO-Link Device Diagnosis (Example using the ISE20B-L) 27 8.6.7. IO-Link Device Scope (Example using the ISE20B-L) 27 8.6.8.

ISE20B-L-S is a digital pressure sensor with all the standard features of the ISE20B, while integrating an M12 connection and supporting the IO-Link communication protocol. When paired with an IO-Link master, measured values and settings can be accessed from the HMI screen of a PLC.

ISE20B-L-S is a digital pressure sensor with all the standard features of the ISE20B, while integrating an M12 connection and supporting the IO-Link communication protocol. When paired with an IO-Link master, measured values and settings can be accessed from the HMI screen of a PLC.

Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: B [Panel Mount Adapter, (ZS-46-B)]

Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: M (SI Unit Only, Fixed Unit: kPa, MPa), Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: B [Panel Mount Adapter, (ZS-46-B)]

Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: NPT1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover, Bracket: B [Panel Mount Adapter, (ZS-46-B)], Operation Manual: -

Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: SI Unit Only, Fixed Unit: kPa, MPa, Piping Specification: NPT1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover, Bracket: B [Panel Mount Adapter, (ZS-46-B)], Operation Manual: -