Pressure Range and Rated Pressure Range p. 26 Analog Output p. 26 Functions p. 26 Internal Circuits and Wiring Examples p. 27 Dimensions p. 28 3-Screen Display High-Precision Digital Pressure Switch/ IO-Link Compatible ZSE20B(F)-L/ISE20B-L Series How to Order p. 15 Specifications p. 16 Set Pressure Range and Rated Pressure Range p. 17 Analog Output p. 17 IO-Link: Process Data p. 17 Functions

[F 0] Units selection function Page 31 Units specification Pressure range Default setting ISE20B MPa "Nil" or M ZSE20B(F) kPa ISE20B P psi ZSE20B(F) [F 1] Setting of OUT1 Page 32 Item Explanation Default setting Output mode Either hysteresis mode, window comparator mode, error output or output off can be selected.

Before Use Digital Pressure Switch ZSE20B(F)-L/ISE20B-L Mounting and Installation Outline of Settings [Measurement mode] Function Selection Mode Installation Mounting Mount the optional bracket and panel mount adapter to the pressure switch.

K T 2 X NPN 2 Y PNP 2 A1 A R NPN 2 + 1 () T PNP 2 + 1 A2 B S NPN 2 + 1 V PNP 2 + 1 1 B D + M SI 3 P psi 2 2: 3kPaMPa 1 ( 2m, ) W M5 M5 01 R1/8 N01 NPT1/8 C4L 4mm C6L 6mm -8No.PS-OMU0005CN-C / A ZS-46-A1 38L (2 ) B ZS-46-A2 38L (2 ) ZS-46-B + ZS-46-D ZS-46-5F 5 2 m ZS-27-01 R1/8 ZS-46-N1 NPT1/8 ZS-46-N2 4mm ZS-46-C4L 6mm ZS-46-C6L -9No.PS-OMU0005CN-C OUT1 LCD OUT2

MPa ISE20B ISE20B: 0.050 MPa/ZSE20B: 5.1 kPa/ ZSE20BF: 5.0 kPa "Nil" or M Hysteresis kPa ZSE20B(F) Safety Instructions Bracket A ISE20B Delay time 1.5 ms or less Bracket B psi P ZSE20B(F) Display color OUT1 ON: Green/OUT1 OFF: Red : Arbitrary display These safety instructions are intended to prevent hazardous situations and/or equipment damage.

control Port 1 0: L+ ON, 1: L+ OFF 1 L+ control Port 2 0: L+ ON, 1: L+ OFF 5 2 L+ control Port 3 0: L+ ON, 1: L+ OFF 3 L+ control Port 4 0: L+ ON, 1: L+ OFF 4..7 Reserved 0 -105No.EX-OMX1011 Configuration format (EX600-LAB1 / EX600-LBB1) Byte 6 to 45 EX600-LAB1 / EX600-LBB1 (46 byte) Byte Bit Parameter Setting value PortConfig Port 1 0: Deactivated 1: IOL_Manual 2: IOL_Autostart 3:

ISE20B-L-S is a digital pressure sensor with all the standard features of the ISE20B, while integrating an M12 connection and supporting the IO-Link communication protocol. When paired with an IO-Link master, measured values and settings can be accessed from the HMI screen of a PLC.

ISE20B-L-S is a digital pressure sensor with all the standard features of the ISE20B, while integrating an M12 connection and supporting the IO-Link communication protocol. When paired with an IO-Link master, measured values and settings can be accessed from the HMI screen of a PLC.

Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: Unit Selection Function, Piping Specification: M5 (Female Thread), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: D [Panel Mount Adapter + Front Protection Cover, (ZS-46-D)], Operation Manual: Y (w/o Operation Manual, w/o Calibration Certificate)

Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: Unit Selection Function, Piping Specification: Female Thread, Lead Wire: Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover, Bracket: D [Panel Mount Adapter + Front Protection Cover, (ZS-46-D)], Operation Manual: w/o Operation Manual, w/o Calibration Certificate

IO-Link Device Process Data (Example using the ISE20B-L) 24 8.6.3. IO-Link Device Identification (Example using the ISE20B-L) 24 8.6.4. IO-Link Device Observation (Example using the ISE20B-L) 25 8.6.5. IO-Link Device Parameter (Example using the ISE20B-L) 26 8.6.6. IO-Link Device Diagnosis (Example using the ISE20B-L) 27 8.6.7. IO-Link Device Scope (Example using the ISE20B-L) 27 8.6.8.