SMC Corporation of America
Elite Part Number Search
Search Results "ISE20B-L-P-N01-WD"

Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: D [Panel Mount Adapter + Front Protection Cover, (ZS-46-D)],

Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: NPT1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover, Bracket: D [Panel Mount Adapter + Front Protection Cover, (ZS-46-D)], Operation

The ISE2 series is a compact, pressure switch (for positive pressure) and can be integrated with ZX or ZR vacuum systems. The ISE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., 3 SCREEN HI PRECISION DIG PRESS SWITCH, PRESSURE SWITCH, ISE1-6, N59, 73 lb

/ IO-Link Compatible ZSE20B(F)-L/ISE20B-L Series How to Order p. 15 Specifications p. 16 Set Pressure Range and Rated Pressure Range p. 17 Analog Output p. 17 IO-Link: Process Data p. 17 Functions p. 17 Internal Circuits and Wiring Examples p. 19 Dimensions p. 20 Function Details p. 34 Made to Order p. 38 Safety Instructions Back cover 8 1 Output 3-Screen Display High-Precision Digital Pressure

IODD file 1 1 ISE20B-L(-M)SMC-ISE20B-L-ymmdd-IODD1.1 2 ISE20B-L-PSMC-ISE20B-L-P-ymmdd-IODD1.1 3 ZSE20B-L(-M)SMC-ZSE20B-L-ymmdd-IODD1.1 4 ZSE20B-L-PSMC-ZSE20B-L-P-ymmdd-IODD1.1 5 ZSE20BF-L(-M)SMC-ZSE20BF-L-ymmdd-IODD1.1 6 ZSE20BF-L-PSMC-ZSE20BF-L-P-ymmdd-IODD1.1 1: "ymmdd" indicates the file preparation date. y is the year, mm is the month and dd is the date.

[F 0] Units selection function Page 31 Units specification Pressure range Default setting ISE20B MPa "Nil" or M ZSE20B(F) kPa ISE20B P psi ZSE20B(F) [F 1] Setting of OUT1 Page 32 Item Explanation Default setting Output mode Either hysteresis mode, window comparator mode, error output or output off can be selected.

Before Use Digital Pressure Switch ZSE20B(F)-L/ISE20B-L Mounting and Installation Outline of Settings [Measurement mode] Function Selection Mode Installation Mounting Mount the optional bracket and panel mount adapter to the pressure switch.

MPa ZSE20B(F) kPa P ISE20B psi ZSE20B(F) [F 1] OUT1 32 OFF ONOFF ISE20B 0.500 MPa ZSE20B -50.5 kPa ZSE20BF50.0 kPa ISE20B0.050 MPa ZSE20B 5.1 kPa ZSE20BF5.0 kPa 1.5ms OUT1 ON OUT1 OFF -29No.PS-OMU0005CN-C [F 2] OUT2 35 [F 1]OUT1 [F 3] 37 0 ms [F 4] 38 [F 5] FUNC 40 [F 6] 42 0% [F10] 43 std() [F11] 49 1000 [F80] 50 OFF [F81] 51 OFF [F82] 53 A [F90] 54 OFF [F96] 56 [F97

MPa ISE20B ISE20B: 0.050 MPa/ZSE20B: 5.1 kPa/ ZSE20BF: 5.0 kPa "Nil" or M Hysteresis kPa ZSE20B(F) Safety Instructions Bracket A ISE20B Delay time 1.5 ms or less Bracket B psi P ZSE20B(F) Display color OUT1 ON: Green/OUT1 OFF: Red : Arbitrary display These safety instructions are intended to prevent hazardous situations and/or equipment damage.

Catalogs New Products Guide Actuators Compact Slide Air Slide Table Compact Guide Cylinder Series MXH-Z Series MXQ Series MGP-Z P .846 P .868 P .1000 Smooth/Low Speed Cylinder Clamp Cylinder Pin Clamp Cylinder Series CY/CX Series CK1-Z Series C(L)KQG32/C(L)KU32 P .1064 P .1268 P .1296 Pin Plate Cylinder (Reference support block machinable type) C(L)KU32-X2359 For High Precision Positioning

Panel mounl adapter H i s h-p reci s io n D i s *"l?

Panel mounl adapter H i s h-p reci s io n D i s *"l?

control Port 1 0: L+ ON, 1: L+ OFF 1 L+ control Port 2 0: L+ ON, 1: L+ OFF 5 2 L+ control Port 3 0: L+ ON, 1: L+ OFF 3 L+ control Port 4 0: L+ ON, 1: L+ OFF 4..7 Reserved 0 -105No.EX-OMX1011 Configuration format (EX600-LAB1 / EX600-LBB1) Byte 6 to 45 EX600-LAB1 / EX600-LBB1 (46 byte) Byte Bit Parameter Setting value PortConfig Port 1 0: Deactivated 1: IOL_Manual 2: IOL_Autostart 3:

Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: Unit Selection Function, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: D [Panel Mount Adapter + Front Protection Cover, (ZS-46-D)]

Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: Unit Selection Function, Piping Specification: NPT1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover, Bracket: D [Panel Mount Adapter + Front Protection Cover, (ZS-46-D)], Operation Manual: -

IO-Link Device Process Data (Example using the ISE20B-L) 24 8.6.3. IO-Link Device Identification (Example using the ISE20B-L) 24 8.6.4. IO-Link Device Observation (Example using the ISE20B-L) 25 8.6.5. IO-Link Device Parameter (Example using the ISE20B-L) 26 8.6.6. IO-Link Device Diagnosis (Example using the ISE20B-L) 27 8.6.7. IO-Link Device Scope (Example using the ISE20B-L) 27 8.6.8.