SMC Corporation of America
Elite Part Number Search
Search Results "ISE20B-T-01-S"

How to Order Rated pressure range ISE20B 0.1 to 1 MPa M For positive pressure ISE20B M5 X For vacuum/ compound pressure ZSE20B X M M5 q w e r t y u q Rated pressure range w Output specification e Unit specification ZSE20B 0 to 101 kPa ZSE20BF 100 to 100 kPa Symbol Description R NPN open collector 2 outputs + Analog voltage output*1 S NPN open collector 2 outputs + Analog current output*1

Connector pin numbers -20No.PS-OMU0006-D Internal circuit and wiring examples Z/ISE20B(F)---Output specification -S/-R (Analog output mode) Switch output NPN open collector output type-2 output Max. 28 V, 80 mA Residual voltage 1 V or less R: Analog output 1 to 5 V Output impedance 1 k S: Analog output 4 to 20 mA Max. load impedance Power supply voltage 12 V: 300 Power supply voltage 24

K T 2 X NPN 2 Y PNP 2 A1 A R NPN 2 + 1 () T PNP 2 + 1 A2 B S NPN 2 + 1 V PNP 2 + 1 1 B D + M SI 3 P psi 2 2: 3kPaMPa 1 ( 2m, ) W M5 M5 01 R1/8 N01 NPT1/8 C4L 4mm C6L 6mm -8No.PS-OMU0005CN-C / A ZS-46-A1 38L (2 ) B ZS-46-A2 38L (2 ) ZS-46-B + ZS-46-D ZS-46-5F 5 2 m ZS-27-01 R1/8 ZS-46-N1 NPT1/8 ZS-46-N2 4mm ZS-46-C4L 6mm ZS-46-C6L -9No.PS-OMU0005CN-C OUT1 LCD OUT2

Bit line Bit Details 7 6 5 4 3 2 1 0 Time base Multiplier Bit 0 to 5: Multiplier (0 to 1) Bit 6 to 7: time base (00, 01, 10) Calculation condition Time base Time base value Calculation Cycle time 00 0.1 ms Multiplier x Time base 0.4 ms to 6.3 ms 01 0.4 ms 6.4 ms + multiplier x Time base 6.4 ms to 31.6 ms 10 1.6 ms 32.0 ms + multiplier x Time base 32.0 ms to 132.8 ms -78No.EX-OMZ0024 Data

Bit line Bit Details 7 6 5 4 3 2 1 0 Time base Multiplier Bit 0 to 5: Multiplier (0 to 1) Bit 6 to 7: time base (00, 01, 10) Calculation condition Time base Time base value Calculation Cycle time 00 0.1 ms Multiplier x Time base 0.4 ms to 6.3 ms 01 0.4 ms 6.4 ms + multiplier x Time base 6.4 ms to 31.6 ms 10 1.6 ms 32.0 ms + multiplier x Time base 32.0 ms to 132.8 ms -78No.EX-OMX1011 Data

(-M)-: 334 (0x014E) ISE20B-L-P-: 335 (0x014F) ZSE20B-L(-M)-: 336 (0x0150) Device ID ZSE20B-L-P-: 337 (0x0151) ZSE20BF-L(-M)-: 338 (0x0152) ZSE20BF-L-P-: 339 (0x0153) 6: The configuration file can be downloaded from the SMC website, https://www.smcworld.com -91No.PS-OMV0006-D Dimensions M5 type 01/N01 type Piping specifications Port size A 01 R1/8 Width across flats 10 N01 NPT1/8 Width across

MPa ISE20B ISE20B: 0.050 MPa/ZSE20B: 5.1 kPa/ ZSE20BF: 5.0 kPa "Nil" or M Hysteresis kPa ZSE20B(F) Safety Instructions Bracket A ISE20B Delay time 1.5 ms or less Bracket B psi P ZSE20B(F) Display color OUT1 ON: Green/OUT1 OFF: Red : Arbitrary display These safety instructions are intended to prevent hazardous situations and/or equipment damage.

Units specification Pressure range Default setting ISE20B: 0.050 MPa/ZSE20B: 5.0 kPa/ ZSE20BF: 5.0 kPa Hysteresis ISE20B MPa "Nil" or M ZSE20B(F) kPa Delay time 0.00 sec.

The ISE20B-S is a digital pressure sensor with all standard features of the ISE20B, while integrating an M12 connection. M12 permits a stable connection for sensor installations outside a cabinet. The sensor has an informative, easy to read 3 screen, 3 color display.

ISE20B-L-S is a digital pressure sensor with all the standard features of the ISE20B, while integrating an M12 connection and supporting the IO-Link communication protocol. When paired with an IO-Link master, measured values and settings can be accessed from the HMI screen of a PLC.

ISE20B-L-S is a digital pressure sensor with all the standard features of the ISE20B, while integrating an M12 connection and supporting the IO-Link communication protocol. When paired with an IO-Link master, measured values and settings can be accessed from the HMI screen of a PLC.

IO-Link Device Process Data (Example using the ISE20B-L) 24 8.6.3. IO-Link Device Identification (Example using the ISE20B-L) 24 8.6.4. IO-Link Device Observation (Example using the ISE20B-L) 25 8.6.5. IO-Link Device Parameter (Example using the ISE20B-L) 26 8.6.6. IO-Link Device Diagnosis (Example using the ISE20B-L) 27 8.6.7. IO-Link Device Scope (Example using the ISE20B-L) 27 8.6.8.

Sub-plate Without valve 3 SY 27 0M 1 W1 01 w e t r q Base gasket is included.

I f a p re s s u re g re a t e r t h a n t h e s e t p re s s u re i s re a c h e d , t h e u n i t w i l l o p e n , c l o s i n g w h e n p re s s u re i s l e s s t h a n s e t pressure.

L1 H (Width across flats) L2 Metric Size [mm] Model d T H D1 D3 L1 L2 L3 L4 Note 1) A Note 2) M Weight [g] Unlocked Locked Unlocked Locked AS221F-01-23(S)A 3.2 7.2 12 19.1 26.2 19.1 30.6 29.2 27.5 26.1 13.3 9 (9) AS221F-01-04(S)A 4 8.2 AS221F-01-06(S)A 6 10.4 10 (9) AS221F-01-08(S)A 8 13.2 22.4 29.5 14.2 11 (10) AS221F-01-10(S)A 10 15.9 25.3 32.4 15.6 12 (11) AS221F-02-23(S)A 3.2 1/8 13 (

-A22 ZPT125 50-(B/N/T)01-A22 ZPT125 75-(B/N/T)01-A22 ZPT125 100-(B/N/T)01-A22 ZPB-T1 25-(B/N/T)01 ZPB-T1 50-(B/N/T)01 ZPB-T1 75-(B/N/T)01 ZPB-T1 25-(B/N/T)01 ZPB-T1 50-(B/N/T)01 ZPB-T1 75-(B/N/T)01 ZPB-T2 25-(B/N/T)01 ZPB-T2 50-(B/N/T)01 ZPB-T2 75-(B/N/T)01 ZPB-T2 25-(B/N/T)01 ZPB-T2 50-(B/N/T)01 ZPB-T2 75-(B/N/T)01 ZPB-T3 25-(B/N/T)01 ZPB-T3 50-(B/N/T)01 ZPB-T3 75-(B/N/T)01 ZPB-T3 100-(B

-A22 ZPT125 50-(B/N/T)01-A22 ZPT125 75-(B/N/T)01-A22 ZPT125 100-(B/N/T)01-A22 ZPB-T1 25-(B/N/T)01 ZPB-T1 50-(B/N/T)01 ZPB-T1 75-(B/N/T)01 ZPB-T1 25-(B/N/T)01 ZPB-T1 50-(B/N/T)01 ZPB-T1 75-(B/N/T)01 ZPB-T2 25-(B/N/T)01 ZPB-T2 50-(B/N/T)01 ZPB-T2 75-(B/N/T)01 ZPB-T2 25-(B/N/T)01 ZPB-T2 50-(B/N/T)01 ZPB-T2 75-(B/N/T)01 ZPB-T3 25-(B/N/T)01 ZPB-T3 50-(B/N/T)01 ZPB-T3 75-(B/N/T)01 ZPB-T3 100-(B

How to Order Sub-plate Assembly System Components System Solenoid valve Speed controller Silencer Tube bore x Length Pilot type Nil R External pilot Internal pilot AS2000-01 (S = 2.5 mm2) AN110-01 (S = 35 mm2) AS3000-02 (S = 12 mm2) AN110-01 (S = 35 mm2) AS3000-02 (S = 12 mm2) AN110-01 (S = 35 mm2) AS4000-02 (S = 21 mm2) AN110-01 (S = 35 mm2) AS4000-02 (S = 21 mm2) AN110-01 (S = 35 mm2) T0425