Your search for ISE1-6 returned 30 result(s)
There were no hits with the full part number, but there were 67 hits in the keyword search.
There were no hits with the full part number, but there were 54 hits in the keyword search.
Product Information » New Products Search Results
The ISE2 series is a compact, pressure switch (for positive pressure) and can be integrated with ZX or ZR vacuum systems. The ISE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., 3 SCREEN HI PRECISION DIG PRESS SWITCH, PRESSURE SWITCH, ISE1-6, N59, 67 lb
K T 2 X NPN 2 Y PNP 2 A1 A R NPN 2 + 1 () T PNP 2 + 1 A2 B S NPN 2 + 1 V PNP 2 + 1 1 B D + M SI 3 P psi 2 2: 3kPaMPa 1 ( 2m, ) W M5 M5 01 R1/8 N01 NPT1/8 C4L 4mm C6L 6mm -8No.PS-OMU0005CN-C / A ZS-46-A1 38L (2 ) B ZS-46-A2 38L (2 ) ZS-46-B + ZS-46-D ZS-46-5F 5 2 m ZS-27-01 R1/8 ZS-46-N1 NPT1/8 ZS-46-N2 4mm ZS-46-C4L 6mm ZS-46-C6L -9No.PS-OMU0005CN-C OUT1 LCD OUT2
How to Order Rated pressure range ISE20B 0 to 1 MPa ISE20B M5 L M For positive pressure For vacuum/ compound pressure ZSE20B L M M5 q w e r t y u q Rated pressure range w Output specification e Unit specification ZSE20B 0 to 100 kPa ZSE20BF 100 to 100 kPa Symbol Description Symbol Description Nil Units selection function*1 M SI unit only*2 P Units selection function (Initial value psi)*1
IODD file 1 1 ISE20B-L(-M)SMC-ISE20B-L-ymmdd-IODD1.1 2 ISE20B-L-PSMC-ISE20B-L-P-ymmdd-IODD1.1 3 ZSE20B-L(-M)SMC-ZSE20B-L-ymmdd-IODD1.1 4 ZSE20B-L-PSMC-ZSE20B-L-P-ymmdd-IODD1.1 5 ZSE20BF-L(-M)SMC-ZSE20BF-L-ymmdd-IODD1.1 6 ZSE20BF-L-PSMC-ZSE20BF-L-P-ymmdd-IODD1.1 1: "ymmdd" indicates the file preparation date. y is the year, mm is the month and dd is the date.
Settable range of user set value Settable value range Range Lower limit Upper limit -10..+10 V -10.50 to +10.45 V -10.45 to +10.50 V -5..+5 V -5.25 to +5.22 V -5.22 to +5.25 V -20..+20 mA -21.00 to +20.90 mA -20.90 to +21.00 mA 0..10 V 0.00 to +10.45 V +0.05 to +10.50 V 0..5 V 0.00 to +5.22 V +0.03 to +5.25 V 1..5 V +0.75 to +5.22 V +0.78 to +5.25 V 0..20 mA 0.00 to +20.90 mA +0.10 to +21.00
Settable range of user set value Settable value range Range Lower limit Upper limit -10..+10 V -10.50 to +10.45 V -10.45 to +10.50 V -5..+5 V -5.25 to +5.22 V -5.22 to +5.25 V -20..+20 mA -21.00 to +20.90 mA -20.90 to +21.00 mA 0..10 V 0.00 to +10.45 V +0.05 to +10.50 V 0..5 V 0.00 to +5.22 V +0.03 to +5.25 V 1..5 V +0.75 to +5.22 V +0.78 to +5.25 V 0..20 mA 0.00 to +20.90 mA +0.10 to +21.00
ISE20B : 0x02440x1450 Z/ISE20B 0x0BB8 (3000) P_1(n_1) (5805200) 0x03F4 (1012) 0 R/W (Setting of switch U16 ZSE20B : 0x02580x1450 (6005200) ZSE20BF : 0x03840x13EC (9005100) ZSE20BF point of OUT1) 0x0FA0 (4000) ISE20B 0x04B0 (1200) Setting of OUT1 hysteresis.
Z Without lead wire with connector W With lead wire with connector (2 m) + Rubber cover for connector (silicon rubber) ZS-33-F S 1 2 ZS-33-D S 1 2 ZS-33-D IN IN Lead wire length 2 m Lead wire length 2 m Option 2 R Bracket (For without flow adjustment valve) S Bracket (For with flow adjustment valve) T Panel mount adapter (For without flow adjustment valve) Nil None ZS-33-J ZS-33-M ZS-33-
(example: If the Pressure switch with output impedance of 1k is connected to the A/D converter to detect the analog output of 5V, the detected voltage by the A/D converter becomes 5(V) x 1(M)/(1(k) + 1(M)) 4.995(V), and there is an error of approximate 0.005 V). Output impedance The operation principle of the switch output. Normal output and reverse output can be selected.
Connector pin numbers -18No.PS-OMS0007-H Internal circuit and wiring examples Z/ISE20(F)---Output specification -N NPN open collector 1 output Max. 28 V, 80 mA Residual voltage: 1 V or less -P PNP open collector 1 output Max. 80 mA Residual voltage: 1 V or less -19No.PS-OMS0007-H Outline of Settings [Measurement mode] Power is supplied.
Lead wire: 0.6 m) C W/suction filter (Mounting on ZX unit) M5 x 0.8 0X Connector type (Lead wire: 3 m) CL W/suction filter (Mounting on ZX unit) M6 x 1 (Option) 0XY Without connector Base mounting (Mounting on ZR unit) 0R CN Note) Single mounting type: M5 x 0.8 (female) threaded.
(example: If the Pressure switch with output impedance of 1 k is connected to the A/D converter to detect the analogue output of 5 V, the detected voltage by the A/D converter becomes 5(V) 1(M)/(1(k) + 1(M)) 4.995(V), and there is an error of approximate 0.005 V). Output impedance Output type The operation type of the switch output.
MPa ISE20B ISE20B: 0.050 MPa/ZSE20B: 5.1 kPa/ ZSE20BF: 5.0 kPa "Nil" or M Hysteresis kPa ZSE20B(F) Safety Instructions Bracket A ISE20B Delay time 1.5 ms or less Bracket B psi P ZSE20B(F) Display color OUT1 ON: Green/OUT1 OFF: Red : Arbitrary display These safety instructions are intended to prevent hazardous situations and/or equipment damage.
1 W Z (2 m) (2 m) + () 2 R S () () T V () () A A B B -11No.PF-OMJ0005CN-I IN OUT X693 IN OUT 73 IN OUT X694 IN OUT 73 X731 (Ar)(CO2) (ArCO2) 92:890:1080:2070:3060:40 75 / ZS-33-D 2 m () ZS-33-F ZS-33-J () ZS-33-JS () ZS-33-M () 2 ZS-33-MS () 3 ZS-33-R DIN 1 2 3 4 5 DIN F02(G1/4)DIN -12No.PF-OMJ0005CN-I LED UP) (DOWN) (OUT2) (OUT1) SET) (OUT ) (IN ) (OUT1
to 20 mA) output type PFM7--DMax. 28 V, 80 mA Internal voltage drop: 1 V or less C: Analogue output: 1 to 5 V Output impedance: 1 k D: Analogue output: 4 to 20 mA Max. load impedance: 600 Min. load impedance: 50 NPN (1 output) + External input type PFM7--GMax. 28 V, 80 mA Internal voltage drop: 1 V or less External input: No voltage input (reed switch or solid state), 30 ms or more -18No.PF-OMJ0006
IO-Link Device Process Data (Example using the ISE20B-L) 24 8.6.3. IO-Link Device Identification (Example using the ISE20B-L) 24 8.6.4. IO-Link Device Observation (Example using the ISE20B-L) 25 8.6.5. IO-Link Device Parameter (Example using the ISE20B-L) 26 8.6.6. IO-Link Device Diagnosis (Example using the ISE20B-L) 27 8.6.7. IO-Link Device Scope (Example using the ISE20B-L) 27 8.6.8.