There were no hits with the full part number, but there were 54 hits in the keyword search.
Product Information » New Products Search Results
p. 24 IO-Link IP65 1 output ZSE/ISE20B-L p. 15 Air General fluids For vacuum pressure For compound pressure For positive pressure For vacuum pressure For compound pressure For positive pressure (1 MPa) For positive pressure (2 MPa) ZSE20B(-L) ZSE20BF(-L) ISE20B ZSE20C ZSE20CF ISE20C ISE20C IO-Link compatible/ L type 2 MPa 1 MPa 1 MPa 1 MPa IO-Link compatible/ L type 100 kPa 100 kPa 100 kPa
IODD file 1 1 ISE20C-L(-M)SMC-ISE20C-L-ymmdd-IODD1.1 2 ISE20C-L-PSMC-ISE20C-L-P-ymmdd-IODD1.1 3 ZSE20C-L(-M)SMC-ZSE20C-L-ymmdd-IODD1.1 4 ZSE20C-L-PSMC-ZSE20C-L-P-ymmdd-IODD1.1 5 ZSE20CF-L(-M)SMC-ZSE20CF-L-ymmdd-IODD1.1 6 ZSE20CF-L-PSMC-ZSE20CF-L-P-ymmdd-IODD1.1 7 ISE20CH-L(-M)SMC-ISE20CH-L-ymmdd-IODD1.1 8 ISE20CH-L-PSMC-ISE20CH-L-P-ymmdd-IODD1.1 1: "ymmdd" indicates the file preparation date
ISE20CH () () () () 3 MPa,kPa,kgf/cm 2,bar,psi,InHg, mmHg MPa,kPa,kgf/cm 2,bar,psi LCD 3 (X2) 1)/ 2) 1)4 7 2)4 (1 11 7 ) ON OUT1OUT2 4 0,10,50,100,500,1000,5000 ms IP65 AC250 V 1 2 M(DC50 V ) -550 -1060 () 3585RH() UL/CSA(E216656)CE(EMC RoHS ) 2 m 1(0 ms) 2 3MPa/kPa 490% 5 02(L) N02(L) F02(L) C01(L) A2(L) B2(L) R1/4 NPT1/4 G1/4 Rc1/8 URJ1/4 TSJ1/4 SUS630SUS304 () 51 g 51
Piping/weight specifications Product No. 02(L) N02(L) F02(L) C01(L) A2(L) B2(L) Port size R1/4 NPT1/4 G1/4 Rc1/8 URJ1/4 TSJ1/4 fluid contact Materials in part Pressure-sensing part Pressure sensor: SUS630, Fitting: SUS304 Body (Rear piping) 51 g 51 g 48 g 47 g 54 g 46 g Weight Body (Bottom piping) 77 g 78 g 74 g 65 g 81 g 72 g Lead wire with connector +39 g Leakage 1 x 10-5Pa m3/s 1 x 10
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: C01 (Rc1/8), Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A3 (Bracket C)
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: Rc1/8, Piping Direction: Bottom Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Bracket C, Operation Manual: -
(Piping specifications A2(L) and B2(L) are excluded.) ZSP PS Specifications ISA Model 500 kPa ZSE80(F) 1.5 MPa ISE80 PSE Withstand pressure Applicable fluid Fluids do not corrode stainless steel 316L IS Models other than above are the same specifications as standard.
Before Use Digital Pressure Switch ZSE20C(F)-L/ISE20C(H)-L Mounting and Installation Outline of Settings [Measurement mode] Function Selection Mode Installation Mounting Mount the optional bracket and panel mount adapter to the pressure switch.
Mounting with bracket Fix the bracket to the Pressure switch with the set screws M3 x 5 L (2 pcs.) supplied. The required tightening torque is 0.5 to 0.7 Nm.
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: C01 (Rc1/8), Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A3 (Bracket C)
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: Rc1/8, Piping Direction: Bottom Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Bracket C, Operation Manual: -
Refer to L dimensions Enter a number from the DIN rail dimension table below. d L 8 (10) D (24) (35) 5.5 A L Rail mounting hole pitch: 12.5 0 98 24.8 5 160.5 40.6 7 185.5 46.9 1 110.5 28 6 173 43.8 8 198 50.1 2 123 31.1 9 210.5 53.3 3 135.5 34.3 4 148 37.4 No.
(For type 20 manifold) SYJ5 10 2 1 3 5 L M5 Body ported 10 SYJ5 4 2 5 3 L CE-compliant Base mounted Nil Q CE-compliant Note) AC-type models that are CE-compliant have DIN terminals only.
Refer to page 642 for the lead wire length of L and M plug connectors. Refer to page 645 for the connector assembly with cover for L and M plug connectors. 616 3 Port Pilot Solenoid Valve 10-SYJ500 Construction r w t q y e r w t q y e N.C. N.O.
ISE20C(H)-L is CE and RoHS compliant, with an IP65 enclosure rating.
ISE20C(H)-L is CE and RoHS compliant, with an IP65 enclosure rating.
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: IO-Link/Switch: 1 Output (PNP or NPN), Switching Type for Switch Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire,