There were no hits with the full part number, but there were 54 hits in the keyword search.
Product Information » New Products Search Results
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: IO-Link/Switch: 1 Output (PNP or NPN), Switching Type for Switch Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire,
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: IO-Link/Switch: 1 Output (PNP or NPN), Switching Type for Switch Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof
The ISE2 series is a compact, pressure switch (for positive pressure) and can be integrated with ZX or ZR vacuum systems. The ISE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., 3 SCREEN HI PRECISION DIG PRESS SWITCH, PRESSURE SWITCH, ISE1-6, N59, 117.00000 lb
(H) Series IP65 ZSE20C(F)/ISE20C(H) ZSE20B(F)/ISE20B ZSE20B(F)-L/ISE20B-L ZSE20A(F)/ISE20A ZSE20(F)/ISE20 Function Details Made to Order How to Order Rated pressure range ISE20C 0.1 to 1 MPa ISE20CH 0.1 to 2 MPa M For positive pressure ISE20C 02 X For vacuum/ compound pressure ZSE20C X M 02 q w e r t y u i o q Rated pressure range w Output specification u Option 2 * Note that the optional
IODD file 1 1 ISE20C-L(-M)SMC-ISE20C-L-ymmdd-IODD1.1 2 ISE20C-L-PSMC-ISE20C-L-P-ymmdd-IODD1.1 3 ZSE20C-L(-M)SMC-ZSE20C-L-ymmdd-IODD1.1 4 ZSE20C-L-PSMC-ZSE20C-L-P-ymmdd-IODD1.1 5 ZSE20CF-L(-M)SMC-ZSE20CF-L-ymmdd-IODD1.1 6 ZSE20CF-L-PSMC-ZSE20CF-L-P-ymmdd-IODD1.1 7 ISE20CH-L(-M)SMC-ISE20CH-L-ymmdd-IODD1.1 8 ISE20CH-L-PSMC-ISE20CH-L-P-ymmdd-IODD1.1 1: "ymmdd" indicates the file preparation date
X M 2 3 ISE20C -0.100~1.000 MPa Y ZSE20C 0.0~-101.0 kPa K ZSE20CF -100.0~100.0 kPa T ISE20CH -0.100~2.000 MPa 24 X NPN2 A1 A Y PNP2 A3 C R NPN2+1 B T PNP2+1 E S NPN2+1 D + V PNP2+1 1: F + 4 2 M SI3 1 P psi2 2 3 kPaMpa (2m ) W 2 R1/4 C01 Rc1/8 N02 NPT1/4 A2 URJ1/4 L F02 G1/4 B2 TSJ1/4 2 2 () L() A A1 ZS-46-A1 C A3 ZS-46-E B ZS-46-B E ZS-35-B D ZS-46-D + F ZS-35-E
Piping/weight specifications Product No. 02(L) N02(L) F02(L) C01(L) A2(L) B2(L) Port size R1/4 NPT1/4 G1/4 Rc1/8 URJ1/4 TSJ1/4 fluid contact Materials in part Pressure-sensing part Pressure sensor: SUS630, Fitting: SUS304 Body (Rear piping) 51 g 51 g 48 g 47 g 54 g 46 g Weight Body (Bottom piping) 77 g 78 g 74 g 65 g 81 g 72 g Lead wire with connector +39 g Leakage 1 x 10-5Pa m3/s 1 x 10
(Piping specifications A2(L) and B2(L) are excluded.) ZSP PS Specifications ISA Model 500 kPa ZSE80(F) 1.5 MPa ISE80 PSE Withstand pressure Applicable fluid Fluids do not corrode stainless steel 316L IS Models other than above are the same specifications as standard.
min Instantaneous flow 2 to 210 L/min Set flow rate range Accumulated flow 0 to 999,999,999 L Flow Instantaneous flow 1 L/min Minimum setting unit Accumulated flow 1 L Accumulated volume per pulse (Pulse width = 50 msec.) 1 L/pulse Accumulated value hold 2 Every 2 minutes or every 5 minutes.
ON-OFF () 1 L/min ,10 11 12 1 L/min SI SI ON-OFF ON 0 ripple -15No.PF-OMO0004CN-E AB.
Before Use Digital Pressure Switch ZSE20C(F)-L/ISE20C(H)-L Mounting and Installation Outline of Settings [Measurement mode] Function Selection Mode Installation Mounting Mount the optional bracket and panel mount adapter to the pressure switch.
Cooling capacity (50/60 Hz)3 [W] 1000/1200 1600/1800 1000/1200 1600/1800 Heating capacity (50/60 Hz)4 [W] 400 500 Temperature stability5 [C] 0.1 Pump capacity (50/60 Hz)6 [MPa] 0.13 (at 7 L/min)/0.18 (at 7 L/min) For Options T, MT: 0.36 (at 7 L/min)/0.42 (at 10 L/min) Rated flow (50/60 Hz)7 [L/min] 7/7 For Options T, MT: 7/10 Flow display range21 [L/min] 2 to 16 Electric conductivity display
Acid consumption amount (at pH4.8) [mg/L] 100 or less v Total hardness [mg/L] 200 or less v Calcium hardness (CaCO3) [mg/L] 150 or less v Ionic state silica (SiO2) [mg/L] 50 or less v Iron (Fe) [mg/L] 1.0 or less v v Copper (Cu) [mg/L] 0.3 or less v Sulfide ion (S2) [mg/L] Should not be detected v Ammonium ion (NH4+) [mg/L] 1.0 or less v Residual chlorine (Cl) [mg/L] 0.3 or less v Free carbon
Units selection function W Wetted part (or part exposed to fluid) The part of the Pressure switch which is in contact with the detected fluid, such as a pressure sensor, seal, or fitting. Window comparator mode An output type which holds the output when the pressure is within a certain range. (Refer to "List of output modes" on page 26).
ISE20C(H)-L is CE and RoHS compliant, with an IP65 enclosure rating.
ISE20C(H)-L is CE and RoHS compliant, with an IP65 enclosure rating.
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: IO-Link/Switch: 1 Output (PNP or NPN), Switching Type for Switch Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported)
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: IO-Link/Switch: 1 Output (PNP or NPN), Switching Type for Switch Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: -, Bracket: -, Operation Manual: -