SMC Corporation of America
Elite Part Number Search
Search Results "ISE20C-R-P-N02L-W"

Rated Pressure Range: -0.1 to 1 MPa, Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: E (Panel Mount Adapter), Operation

Rated Pressure Range: -0.1 to 1 MPa, Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: F (Panel Mount Adapter + Front

Rated Pressure Range: -0.1 to 1 MPa, Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: None, Operation Manual: Operation Manual, Calibration

Rated Pressure Range: -0.1 to 1 MPa, Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Panel Mount Adapter, Operation Manual: w/o Operation

Rated Pressure Range: -0.1 to 1 MPa, Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Panel Mount Adapter + Front Protection Cover

The ISE2 series is a compact, pressure switch (for positive pressure) and can be integrated with ZX or ZR vacuum systems. The ISE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., 3-Screen High Precision Dig Press Switch, PRESSURE SWITCH, ISE1-6, 117 lb

The ISE2 series is a compact, pressure switch (for positive pressure) and can be integrated with ZX or ZR vacuum systems. The ISE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., 3 SCREEN HI PRECISION DIG PRESS SWITCH, PRESSURE SWITCH, ISE1-6, N59, 117.00000 lb

The ISE2 series is a compact, pressure switch (for positive pressure) and can be integrated with ZX or ZR vacuum systems. The ISE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., 3-Screen High Precision Dig Press Switch, PRESSURE SWITCH, ISE1-6, N59, 117 lb

(H) Series IP65 ZSE20C(F)/ISE20C(H) ZSE20B(F)/ISE20B ZSE20B(F)-L/ISE20B-L ZSE20A(F)/ISE20A ZSE20(F)/ISE20 Function Details Made to Order How to Order Rated pressure range ISE20C 0.1 to 1 MPa ISE20CH 0.1 to 2 MPa M For positive pressure ISE20C 02 X For vacuum/ compound pressure ZSE20C X M 02 q w e r t y u i o q Rated pressure range w Output specification u Option 2 * Note that the optional

(-M): 0 ISE20C-L-P: 4 ZSE20C-L(-M): 1 ZSE20C-L-P: 4 ZSE20CF-L(-M): 1 Unit (Selection of display unit) 0x03E8 (1000) 0 R/W Y U8 ZSE20CF-L-P: 4 ISE20CH-L(-M): 0 ISE20CH-L-P: 4 NorP (Selection of PNP/NPN) Setting of switch output specification 0: NPN 1: PNP 0x03E9 (1001) 0 R/W Y U8 0x01 (1) Setting of display color 0: red (Constantly red) 1: Grn (Constantly green) 2: 1SoG CoL (Selection of display

A Rectified value P-1 Rectified value P-1 (Differential) Pressure H-1 (P-3) H-1 (H-2) n-1 Min. B Switch output 1(2) Released ON Work 1 Work 2 Work n Atmosphere OFF ZSE ISE Formula for Obtaining the Set-Value A B Switch output response time when autoshift is input.

X M 2 3 ISE20C -0.100~1.000 MPa Y ZSE20C 0.0~-101.0 kPa K ZSE20CF -100.0~100.0 kPa T ISE20CH -0.100~2.000 MPa 24 X NPN2 A1 A Y PNP2 A3 C R NPN2+1 B T PNP2+1 E S NPN2+1 D + V PNP2+1 1: F + 4 2 M SI3 1 P psi2 2 3 kPaMpa (2m ) W 2 R1/4 C01 Rc1/8 N02 NPT1/4 A2 URJ1/4 L F02 G1/4 B2 TSJ1/4 2 2 () L() A A1 ZS-46-A1 C A3 ZS-46-E B ZS-46-B E ZS-35-B D ZS-46-D + F ZS-35-E

Pressure Characteristics 3 5%F.S. (0 to 0.75 MPa, 0.35 MPa standard) Power supply voltage 12 to 24VDC 10% Ripple (p-p) 10% or less Electrical Current consumption 55 mA or less Protection Polarity protection Display accuracy 3%F.S. Analogue output accuracy 3%F.S.

N (2 m) (2 m) + () 2 R S () () T V () () -11No.PF-OMO0004CN-E / ZS-33-D 2m ZS-33-F ZS-33-J () ZS-33-JS () ZS-33-M () (3.02 ) ZS-33-MS () (3.03 ) ZS-33-R DIN 1 2 3 4 5 DIN F02(G/14)DIN -12No.PF-OMO0004CN-E (OUT) (IN) 1 2 2 INOUT DIN 1 2: LCD LED (UP) (SET) SET (DOWN) UP DOWN 3 ON/OFF (UP) 3 ON/OFF (DOWN) LED (OUT1)/ (SET) OUT1OUT2 OUT1ON OUT2ON

V: Power supply voltage Power consumption P: 1000 [W] Q = P = 1000 [W] P Cooling capacity = Considering a safety factor of 20%, Power consumption 1000 [W] x 1.2 = 1200 [W] e Derive the heat generation amount from the output. w Derive the heat generation amount from the power supply output. Output (shaft power, etc.)

Power consumption P: 7 [kW] Q = P = 7 [kW] Cooling capacity = Considering a safety factor of 20%, 7 [kW] x 1.2 = 8.4 [kW] w Derive the heat generation amount from the power supply output.

Internal circuit and wiring example Z/ISE80Output specification -N NPN open collector output type Max. 28 V, 80 mA Residual voltage 1 V or less -P PNP open collector output type Max. 80 mA Residual voltage 1 V or less -S/-R (Analogue output mode) Switch output NPN open collector output type 2 output Max. 28 V, 8 mA Residual voltage 1 V or less R: Analogue output 1 to 5 V Output impedance

For positive pressure 80 ISE 02 N M For vacuum/ compound pressure M 80 ZSE 02 N Option 3 Rated pressure range Operating Note) manual (Booklet) (CD-ROM) Operating Note) manual 80 80F Calibration certificate Calibration certificate 0 to 101 kPa 100 to 100 kPa Symbol Symbol (Booklet) (CD-ROM) K T R Nil Piping Y W R1/4 (M5 female threaded) Rear ported 02 Note) All texts in both English

PNP Max.80 mA 1 V -S/-R () NPN 2 Max.28 V80 mA 1 V R15 V 1 k S420 mA 12 V 300 24 V 600 50 -S/-R () NPN 2 Max.28 V80 mA 1 V -17No.PS-OMM0002CN-F -V/-T () PNP 2 Max.80 mA 1 V T15 V 1 k V420 mA 12 V 300 24 V 600 50 -V/-T () PNP 2 Max.80 mA 1 V -A NPN2 Max.28 V80 mA 1 V -B PNP2 Max.80 mA 1 V -18No.PS-OMM0002CN-F ONOFF () ON OFF ON5OFF 20 P 1 H_1 [Pa] ON OFF [s] -19No.PS-OMM0002CN-F

Bracket C MPa ISE20C(H) ISE20C: 0.050 MPa/ZSE20C: 5.1 kPa/ ZSE20CF: 5.0 kPa/ISE20CH: 0.100 MPa "Nil" or M Hysteresis Self tapping screws: Nominal size 3 x 8L kPa ZSE20C(F) Self tapping screws: Nominal size 3 x 10L Safety Instructions Bracket A ISE20C(H) Delay time 1.5 ms or less psi P ZSE20C(F) Display color OUT1 ON: Green/OUT1 OFF: Red : Arbitrary display These safety instructions are intended