Pressure Range: ISE70 (0 to 1 MPa), Piping: 02 (Rc 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m), Bracket: A (Bracket A, Interchangeable with ISE70),

Pressure Range: 0 to 1 MPa, Piping: Rc 1/4, Output Specification: I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: Bracket A, Interchangeable with ISE70, Operation Manual/Calibration

The ISE70/75(H) series pressure switches incorporate a large digital display to monitor both coolant and hydraulic fluids. 

(When using switch with neon light: 1000 VAC for 1 min.) 50/60 5 3 4 0.4 3 2 3 0.4 0.1 0.1 How to Order IS3110 (Gasket piping) IS3010-02 (Rc 1/4 thread) IS3 0 02 L1 0 0 JIS Symbol Indicator light Piping method Nil L1 L2 L5 None With neon light/110 VAC With neon light/220 VAC LED/24 VDC Rc 1/4 thread Gasket piping 0 1 Micro switch load type Note) Micro load type: Not available L2 option.

(17) 0 R www.smcworld.com 0x0012 (18) 0 R ISE70-02-L2 0x0013 (19) 0 R ID ISE70-02-L2 0x0014 (20) 0 R Pressure sensor 8 0x0015 (21) 0 R No.

36.6 35 31.1 29.5 13.3 18 (19) AS221F-02-04(S)A 4 8.2 AS221F-02-06(S)A 6 10.4 23.4 32.7 (32.8) AS221F-02-08(S)A 8 13.2 23.9 33.2 (33.3) 14.2 19 (20) AS221F-02-10(S)A 10 15.9 26.9 36.2 (36.3) 15.6 20 (21) AS321F-02-06(S)A 6 1/4 17 (17.5) 13 13.3 40 (40) AS321F-02-08(S)A 8 13.2 22.7 33 14.2 41 (41) AS321F-02-10(S)A 10 15.9 26.7 37 35.7 15.6 42 (42) AS321F-02-12(S)A 12 18.5 29.7 40 34.5 17

ISE70 0 to 1 MPa ISE71 0 to 1.6 MPa Symbol Description Nil Operation manual Y None K Operation manual + Calibration certificate Piping specification Symbol Description 02 Rc1/4 N02 NPT1/4 F02 G1/4*1 T Calibration certificate Option 2 Symbol Description Nil None *1 ISO 1179-1 compliant Output specification*1 A Bracket A (Interchangeable with ISE70) Symbol Description B Bracket B L2 IO-Link

VM230U-02-08A VM-08A 110 g Red VM220-02-30RA VM230-02-30RA VM220U-02-30RA VM230U-02-30RA VM-30AR 58 g Black VM220-02-30BA VM230-02-30BA VM220U-02-30BA VM230U-02-30BA VM-30AB Green VM220-02-30GA VM230-02-30GA VM220U-02-30GA VM230U-02-30GA VM-30AG Yellow VM220-02-30YA VM230-02-30YA VM220U-02-30YA VM230U-02-30YA VM-30AY Push button (Mushroom) Red VM220-02-32RA VM230-02-32RA VM220U-02-32RA VM230U

Example) G36-P4-01-X30 ISA2 ISA2 2 Port Solenoid Valve Regulator PSE VCA27A S 5 DL 02 4 Q AR 20 02 1 B IS Port size Voltage CE compliant 02 02N 02F Rc 1/4 NPT 1/4 G 1/4 Thread type ISG 1 2 3 4 5 6 36 100 VAC 200 VAC 110 VAC 220 VAC 24 VDC 12 VDC 230 VAC Nil N F Rc NPT G ZSM1 Throttle Nil S B K Without throttle and manual lock With throttle With manual lock With manual lock and throttle Semi-standard

(Note 1) I/O 1 P15R P15R P15R P15R P15R P15R 2 I -/VC VC VC/VLA VLA VLA/3 LG LG LG LG LG LG 4 O LA LA LA LA LA LA 5 O LAR LAR LAR LAR LAR LAR 6 O LB LB LB LB LB LB 7 O LBR LBR LBR LBR LBR LBR 8 O LZ LZ LZ LZ LZ LZ 9 O LZR LZR LZR LZR LZR LZR 10 I PP PP/(Note 6) (Note 6) (Note 6) -/PP PD43/PD44 11 I PG PG/-/PG 12 OPC OPC/-/OPC 13 O (Note 4) (Note 4) (Note 4) (Note 4) (Note 4) (Note 4) PD47

LA LA LA LA LA 16 O LAR LAR LAR LAR LAR LAR 17 O LB LB LB LB LB LB 18 O LBR LBR LBR LBR LBR LBR 19 O LZ LZ LZ LZ LZ LZ 20 O LZR LZR LZR LZR LZR LZR 21 O OP OP OP OP OP OP 22 I PG PG/-/PG 23 I PP PP/-/PP 24 I NG NG/-/NG 25 I NP NP/-/NP 26 Note 1.

AS2201F-01-06-X214 AS2301F-01-06-X214 RS H A AS2201F-01-06-X214 AS2301F-01-06-X214 AS2201F-02-06-X214 AS2301F-02-06-X214 RZQ 3. When disassembling to replace the seals and wear ring, refer to the separate disassembly instructions. AS3201F-02-08-X214 AS3301F-02-08-X214 AS3201F-02-08-X214 AS3301F-02-08-X214 MI W S 4.

Abbreviation Connection target (application) Description Supply the following power to L1, L2, L3. For the 1-phase 200 to 230VAC power supply, connect the power supply to L1, L2, and keep L3 open.

Abbreviation Connection target (application) Description Supply the following power to L1, L2, L3. For the 1-phase 200 to 230VAC power supply, connect the power supply to L1, L2, and keep L3 open.

Symbol Connection target (application) Description Supply the following power to L1, L2, and L3. For 1-phase 200 V AC to 240 V AC, connect the power supply to L1 and L3. Leave L2 open. Driver LECSS2-T5 to Power LECSS2-T9 L1/L2/L3 Main circuit power 3-phase 200 V AC to 240 V AC, 50 Hz/60 Hz L1/L2/L3 supply 1-phase 200 V AC to 240 V AC, 50 Hz/60 Hz L1/L3 P3/P4 Connect P3 and P4.

P P/S S S/T T T/P 1 P15R P15R P15R P15R P15R P15R 2 I /VC VC VC/VLA VLA VLA/ 3 LG LG LG LG LG LG 4 O LA LA LA LA LA LA 5 O LAR LAR LAR LAR LAR LAR 6 O LB LB LB LB LB LB 7 O LBR LBR LBR LBR LBR LBR 8 O LZ LZ LZ LZ LZ LZ 9 O LZR LZR LZR LZR LZR LZR 10 I PP PP/ /PP 11 I PG PG/ /PG 12 OPC OPC/ /OPC 13 14 15 I SON SON SON SON SON SON PD03 16 I /SP2 SP2 SP2/SP2 SP2 SP2/ PD04 17 I PC PC/ST1 ST1