Your search for ISE70 returned 30 result(s)
There were no hits with the full part number, but there were 67 hits in the keyword search.
There were no hits with the full part number, but there were 2 hits in the keyword search.
Product Information » New Products Search Results
For AC10-A For AC20-B For AC25-B For AC30-B For AC40-B For AC40-06-B For AC50-B For AC55-B For AC60-B For AC10A-A For AC20A-B For AC30A-B For AC40A-B For AC40A-06-B For AC50A-B For AC60A-B For AC10B-A For AC20B-B For AC25B-B For AC30B-B For AC40B-B For AC40B-06-B For AC50B-B For AC55B-B For AC60B-B For AC20C-B For AC25C-B For AC30C-B For AC40C-B For AC40C-06-B For AC20D-B For AC30D-B
Hysteresis ISE70: 0.050 MPa/ISE71: 0.080 MPa Item Default setting Delay time 0.00 sec. Bracket B (Part No.: ZS-50-B) Unit specification ["Nil" or M]: MPa Display unit Safety Instructions Display colour Output ON: Green/Output OFF: Red (Linked to OUT1) Switch output specifications PNP : Arbitrary display Mode display [F 2] Setting of OUT2 Same setting as [F 1] OUT1.
Pressure Range: ISE70 (0 to 1 MPa), Piping: F02 (G 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m), Bracket: A (Bracket A, Interchangeable with ISE70)
Pressure Range: ISE70 (0 to 1 MPa), Piping: F02 (G 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m), Bracket: A (Bracket A, Interchangeable with ISE70)
Pressure Range: ISE70 (0 to 1 MPa), Piping: F02 (G 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: A (Bracket A, Interchangeable with ISE70)
ON-flow 0.04 40 B p ipe pe 3/4 B p pi 3B 30 1 0.03 2B, pipe 20 0.02 , 5B , 4B pe 1/4 1 B pi 10 Max.
Bracket B Bracket assembly Lead wire with M12 connector, straight Lead wire length: 5m ZS-31-B Lead wire with M12 connector, right-angled Lead wire length: 5m ZS-31-C 16-2-46 3 Series ISE70 Digital Pressure Switch For Air Specifications ISE70 Rated pressure range 0 to 1MPa Set pressure range 0.1 to 1MPa Proof pressure 1.5MPa Set pressure resolution 0.01MPa ZSE ISE Fluid Air, lnert gas, Non-flammable
Pressure Range: ISE70 (0 to 1 MPa), Piping: F02 (G 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type])
Pressure Range: ISE70 (0 to 1 MPa), Piping: F02 (G 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m)
Bar 0 10.000 -1.05 10.50 Psi 0 145.04 -15.2 152.3 (PD) 1000 5000 580 5200 MPa 0 1.6000 -0.105 1.680 kPa 0 1,600.0 -105 1680 Kgf/cm 2 0 16.315 -1.07 17.13 ISE71 Bar 0 16.000 -1.05 16.80 Psi 0 232.06 -15.2 243.7 (PD) 1000 5000 738 5200 ISE70 MPa (PD) PD [MPa] (PD)(ISE70 MPa) -62No.PS-OMV0003CN-G Pr = a (PD) + b (PD) = (Pr b) / a Pr PD a b [] a b MPa 0.00025 -0.25 kPa
Note Bracket A ZS-50-A Interchangeable with ISE70 With 2 mounting screws (M4 x 6L) Bracket B ZS-50-B With 2 mounting screws (M4 x 6L) Lead wire with M12 connector: Straight ZS-31-B Lead wire length: 5 m Lead wire with M12 connector: Right-angled ZS-31-C Lead wire length: 5 m 6 ISE70/71 Series For pressure switch precautions and specific product precautions, refer to the Operation Manual on
0.004 -4 psi 0.05802 -58.02 [Calculation example] (1) Conversion from the process data to the pressure measurement value (For ISE70 series, unit specification MPa and PD = 2000) Pr = a (PD) + b = 0.00025 2000 0.25 = 0.25 [MPa] (2) Conversion from the pressure measurement value to the process data (For ISE70 series, unit specification MPa and Pr = 0.75 [MPa]) (PD) = (Pr b) / a = [0.75
When piping, tighten to an appropriate torque of 13.6 to 15 Nm for ISE70 series and 25 to 28 Nm for ISE75/75H series. Installation Mounting Install using a special bracket (Model: ZS-31-A) available as options. Mounting by bracket Mount the fitting between the bracket assembly and bracket B. Then, mount it on the panel precisely by using M6 screws to prevent shrinkage and play.
10218-1992: Manipulating industrial robots-Safety JIS B 8370: JIS B 8361: JIS B 9960-1: -() JIS B 8433-1993: 2) : : : 1 2 3 1 2 3 4 -2No.PS-OMH0002CN-D / / / / 1 1.5 3) 3) 1 1 () -3No.PS-OMH0002CN-D () () () () -4No.PS-OMH0002CN-D () * (ISE70 ) SUS630SUS430SUS304 (ISE75(H)) ON/OFF (ISE70 ) (10 10 ) UL1310 UL1585 UL -5No.PS-OMH0002CN-D * (50 N ) , ,ISE70 40 NmISE75(H)80
8370: JIS B 8361: JIS B 9960-1: 1 ) JIS B 8433: *2) 1. 2. 3. 1. 2. 3. 4
C 4-O D T 2-P Q E B U W S K L Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com AA I A R AP AB Y + Stroke X J V Z + Stroke AC AD 8-AF AE Stroke range (mm) Bore size (mm) AF AE AD AC AB AA G F N E M D L C K B J AP H I A 20 30 75 16.5 11 12 5.5 45 92 25 60 80 24 60 108