SMC Corporation of America
Elite Part Number Search
Search Results "ISE70-N02-AB-K"

)-B/AR25(K)-B t e q IN OUT t Modular F.R.L. e q r IN OUT w r w AC-A AC-B AR30(K)-B/AR40(K)-B q t AR50(K)-B/AR60(K)-B e IN OUT q t r w e IN OUT r w Component Parts No.

Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: M (SI Unit Only), Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m), Bracket: A (Bracket A, Interchangeable with ISE70), Operation Manual/Calibration Certificate: K (Operation Manual + Calibration Certificate)

Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m), Bracket: A (Bracket A, Interchangeable with ISE70), Operation Manual/Calibration

Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: M (SI Unit Only), Lead Wire: None, Bracket: None, Operation Manual/Calibration Certificate: K (Operation Manual + Calibration Certificate)

1 k Load OUT1 (Black) OUT2 (White) 12 to 24 VDC 12 to 24 VDC Load Load DC () (Blue) DC () (Blue) ZSE40(F) ISE40--30(L)-(M) With auto shift input ZSE40(F) ISE40--70(L)-(M) With auto shift input DC (+) (Brown) Auto shift input (Gray) OUT1 (Black) OUT2 (White) DC (+) (Brown) Auto shift input (Gray) 1.2 k 1.2 k Load 6.8 k 6.8 k Main circuit Main circuit Load OUT1 (Black) OUT2 (White) 12 to 24

Before Use High-precision Digital Pressure Switch ISE70/ISE71-AB Mounting and Installation Outline of Settings [Measurement mode] Function Selection Mode Power is supplied Installation Function selection mode In measurement mode, press the SET button for 3 and 5 sec., to display [F 0]. Select to display the function to be changed [F].

ISE70 0 to 1 MPa ISE71 0 to 1.6 MPa Symbol Description Nil Operation manual Y None K Operation manual + Calibration certificate Piping specification Symbol Description 02 Rc1/4 N02 NPT1/4 F02 G1/4*1 T Calibration certificate Option 2 Symbol Description Nil None *1 ISO 1179-1 compliant Output specification*1 A Bracket A (Interchangeable with ISE70) Symbol Description B Bracket B L2 IO-Link

Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: A (Bracket A, Interchangeable with ISE70)

Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m), Bracket: A (Bracket A, Interchangeable with ISE70)

Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: M (SI Unit Only), Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m), Bracket: A (Bracket A, Interchangeable with ISE70), Operation Manual/Calibration Certificate: Y (None)

Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: A (Bracket A, Interchangeable with ISE70), Operation Manual/Calibration Certificate: Y (None)

Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: M (SI Unit Only), Lead Wire: None, Bracket: A (Bracket A, Interchangeable with ISE70), Operation Manual/Calibration Certificate: Y (None)

Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m), Bracket: A (Bracket A, Interchangeable with ISE70)

Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m), Bracket: A (Bracket A, Interchangeable with ISE70), Operation Manual/Calibration

-2No.PS-OMV0003CN-G / *3) 1 1.5 *3)1 1 [] -3No.PS-OMV0003CN-G () () () () -4No.PS-OMV0003CN-G () * UL UL1310 2 UL1585 2 30 Vrms(42.4 V ) (2 ) UL (1 20 ) -5No.PS-OMV0003CN-G * FG (35 N () ,() *() 6 33 () 20 m DC(-)() * ( ) -6No.PS-OMV0003CN-G () CE 0~50(5 ) (FKMHNBR) * 1015 10 1% 1959 LCD * -7No.PS-OMV0003CN-G ISE70 02 L2 M 3 Y K T ISE70 0~1MPa ISE71 0~1.6MPa 02 Rc1/4 N02

B L O C K P E R F E C T C H E C K B L O C K W I T H V A L V E O R M A N I F O L D Courtesy of Steven Engineering, Inc. !