Your search for ISE70 returned 30 result(s)
There were no hits with the full part number, but there were 67 hits in the keyword search.
There were no hits with the full part number, but there were 2 hits in the keyword search.
Product Information » New Products Search Results
)-B/AR25(K)-B t e q IN OUT t Modular F.R.L. e q r IN OUT w r w AC-A AC-B AR30(K)-B/AR40(K)-B q t AR50(K)-B/AR60(K)-B e IN OUT q t r w e IN OUT r w Component Parts No.
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: M (SI Unit Only), Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m), Bracket: A (Bracket A, Interchangeable with ISE70), Operation Manual/Calibration Certificate: K (Operation Manual + Calibration Certificate)
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m), Bracket: A (Bracket A, Interchangeable with ISE70), Operation Manual/Calibration
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: M (SI Unit Only), Lead Wire: None, Bracket: None, Operation Manual/Calibration Certificate: K (Operation Manual + Calibration Certificate)
1 k Load OUT1 (Black) OUT2 (White) 12 to 24 VDC 12 to 24 VDC Load Load DC () (Blue) DC () (Blue) ZSE40(F) ISE40--30(L)-(M) With auto shift input ZSE40(F) ISE40--70(L)-(M) With auto shift input DC (+) (Brown) Auto shift input (Gray) OUT1 (Black) OUT2 (White) DC (+) (Brown) Auto shift input (Gray) 1.2 k 1.2 k Load 6.8 k 6.8 k Main circuit Main circuit Load OUT1 (Black) OUT2 (White) 12 to 24
Before Use High-precision Digital Pressure Switch ISE70/ISE71-AB Mounting and Installation Outline of Settings [Measurement mode] Function Selection Mode Power is supplied Installation Function selection mode In measurement mode, press the SET button for 3 and 5 sec., to display [F 0]. Select to display the function to be changed [F].
ISE70 0 to 1 MPa ISE71 0 to 1.6 MPa Symbol Description Nil Operation manual Y None K Operation manual + Calibration certificate Piping specification Symbol Description 02 Rc1/4 N02 NPT1/4 F02 G1/4*1 T Calibration certificate Option 2 Symbol Description Nil None *1 ISO 1179-1 compliant Output specification*1 A Bracket A (Interchangeable with ISE70) Symbol Description B Bracket B L2 IO-Link
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: A (Bracket A, Interchangeable with ISE70)
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m), Bracket: A (Bracket A, Interchangeable with ISE70)
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: M (SI Unit Only), Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m), Bracket: A (Bracket A, Interchangeable with ISE70), Operation Manual/Calibration Certificate: Y (None)
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: A (Bracket A, Interchangeable with ISE70), Operation Manual/Calibration Certificate: Y (None)
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: M (SI Unit Only), Lead Wire: None, Bracket: A (Bracket A, Interchangeable with ISE70), Operation Manual/Calibration Certificate: Y (None)
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m), Bracket: A (Bracket A, Interchangeable with ISE70)
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m), Bracket: A (Bracket A, Interchangeable with ISE70), Operation Manual/Calibration
-2No.PS-OMV0003CN-G / *3) 1 1.5 *3)1 1 [] -3No.PS-OMV0003CN-G () () () () -4No.PS-OMV0003CN-G () * UL UL1310 2 UL1585 2 30 Vrms(42.4 V ) (2 ) UL (1 20 ) -5No.PS-OMV0003CN-G * FG (35 N () ,() *() 6 33 () 20 m DC(-)() * ( ) -6No.PS-OMV0003CN-G () CE 0~50(5 ) (FKMHNBR) * 1015 10 1% 1959 LCD * -7No.PS-OMV0003CN-G ISE70 02 L2 M 3 Y K T ISE70 0~1MPa ISE71 0~1.6MPa 02 Rc1/4 N02
B L O C K P E R F E C T C H E C K B L O C K W I T H V A L V E O R M A N I F O L D Courtesy of Steven Engineering, Inc. !