Your search for ISE70 returned 30 result(s)
There were no hits with the full part number, but there were 67 hits in the keyword search.
There were no hits with the full part number, but there were 2 hits in the keyword search.
Product Information » New Products Search Results
Pressure Range: ISE70G (0 to 1 MPa), Piping: F02 (G 1/4, ISO 1179-1 Compliant), Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m)
Pressure Range: ISE70G (0 to 1 MPa), Piping: F02 (G 1/4, ISO 1179-1 Compliant), Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m)
Pressure Range: 0 to 1 MPa, Piping: G 1/4, ISO 1179-1 Compliant, Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: -, Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 1 MPa, Piping: G 1/4, ISO 1179-1 Compliant, Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: -, Operation Manual/Calibration Certificate: -
The ISE70/75(H) series pressure switches incorporate a large digital display to monitor both coolant and hydraulic fluids. These high performance, yet lightweight, pressure controls are available in three styles: the ISE70 for use with air or inert and incombustible gases (monitoring a set rated pressure range between –0.1 to 1MPa), and the ISE75 and ISE75H models (for use with fluids requiring
The ISE70/75(H) series pressure switches incorporate a large digital display to monitor both coolant and hydraulic fluids. These high performance, yet lightweight, pressure controls are available in three styles: the ISE70 for use with air or inert and incombustible gases (monitoring a set rated pressure range between –0.1 to 1MPa), and the ISE75 and ISE75H models (for use with fluids requiring
Input Data2 byteOutput Data0 byte (IO-Link ) ID 131(0x0083) ISE70G-*-L2-*309(0x0135) ISE75G-*-L2-*320(0x0140) ISE76G-*-L2-*321(0x0141) ISE77G-*-L2-*322(0x0142) ID ISE78G-*-L2-*362(0x016A) 1(0 ms) 2 3 ISE70G/ISE75G MPa/kPa ISE76G/ISE77G/ISE78G MPa 490 5https://www.smcworld.com 6 02 N02 F02 Rc1/4 NPT1/4 G1/4 Al2O3(96) ISE70GC3604()FKM+ ISE75G/ISE76G/ISE77G/ISE78GC3604()FKM ISE70G 179 g
No.PS-OMV0009-E PRODUCT NAME High-precision Digital Pressure Switch MODEL / Series / Product Number ISE70G-#-L2 ISE75G-#-L2 ISE76G-#-L2 ISE77G-#-L2 ISE78G-#-L2 Table of Contents Safety Instructions 2 Model Indication and How to Order 9 Summary of Product parts 10 Definition and terminology 12 Mounting and Installation 15 Installation 15 Piping 17 Wiring 19 Outline of Settings [Measurement
/75G/76G/77G Series How to Order ISE70G 02 M L2 Pressure range Piping specification Symbol Description ISE70G 0 to 1 MPa ISE75G 0 to 2 MPa ISE76G 0 to 5 MPa ISE77G 0 to 10 MPa Symbol Description 02 Rc1/4 N02 NPT1/4 F02 G1/4*1 Option 3 Symbol Description Nil Operation manual Y None *1 ISO 1179-1 compliant Orifice K Operation manual + Calibration certificate Symbol Description Nil None T Yes
Unit specification ["Nil" or M]: MPa Hysteresis Display unit Mounting with orifice : Tighten the orifice to a torque of 1.50.1 Nm. : ISE70G/ISE75G/ISE76G/ISE77G/ISE78G can be mounted. Switch output specifications Delay time 0.00 sec.
Uni thread H D1 D2 L1 L2 L5 A Max.
(mm) 1in=25.4mm L4 D3 H (width across flats) T2 A L2 D1 L3 D2 T1 L1 Dimensions A Model T2 H D1 T1 D2 D3 L3 L1 L4 L2 AS12 0-M5-T M5 x 0.8 8 9 M5 x 0.8 9 4.5 10 31 10.3 0.7 28.4 AS12 0-U10/32-T 10-32UNF 10-32UNF AS22 0-01-ST Rc 1/8 12 14.3 R 1/8 AS22 0-F01-ST PF 1/8 14.6 7 18 35.6 14.1 1.5 32 AS22 0-N01-ST NPT 1/8 12.7 NPT 1/8 AS22 0-02-ST Rc 1/4 17 18 R 1/4 AS22 0-F02-ST PF 1/4 19.5 7 27.2
L2 L2 M2 M2 KDM6 KDM Different Diameter Tee: KQ2T 2 x Applicable tubing a Applicable tubing O.D.
Note 2) 3/16", 3/8", 1/2" are made of brass (Electroless nickel plated). 15-9-95 Dimensions L5 Elbow type D3 H Applicable tubing O.D. d (Hexagon width across flats) L4 L3 A D1 M1 L1 L2 D2 T Metric Size Inch Size d T H D2 D3 L1 L2 L3 L4 L5 A M1 d T H D1 D2 D3 L1 L2 L3 L4 L5 A M1 D1 Model Model AS121F-M5-23T AS121F-U10/32-01T 1/8" 8.4 17.3 22.1 12.3 3.2 8.4 5/32" 9.3 12.7 17.3 22.1 12.3 12.7
Piping port ZSM 02: Rc1/4 N02: NPT1/4 F02: G1/4 (ISO1179) PF2 IF 2 1 Data 4 3 With bracket Connector Pin Assignments 44.5 9 34 Output -43 MPa 1 Brown DC (+) 2 White OUT1 (PNP) 3 Blue DC () OUT1 4 Black OUT1 (NPN) U P DOWN SET Output -65 14.5 90 1 Brown DC (+) 2 White NC 3 Blue DC () 26.5 4 Black OUT1 (PNP) 18.3 6 (28.7) 35 46 (38.2) 60 24 Piping port 02: Rc1/4 N02: NPT1/4 F02: G1/4 (ISO1179
Dimensions AS420 AS500 AS600 67.5 74 90 1/4, 3/8, 1/2 3/4 1 38 42 55 122 115 158 112 105 148 50 50 62 L1 L2 L4 Min.