Pressure Range: 0 to 1.6 MPa, Piping: Rc 1/4, Output Specification: Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: -, Operation Manual/Calibration Certificate: -

Before Use High-precision Digital Pressure Switch ISE70/ISE71-AB Mounting and Installation Outline of Settings [Measurement mode] Function Selection Mode Power is supplied Installation Function selection mode In measurement mode, press the SET button for 3 and 5 sec., to display [F 0]. Select to display the function to be changed [F].

IODD file 1 ISE70 SMC-ISE70-ymmdd-IODD1.1 2 ISE71 SMC-ISE71-ymmdd-IODD1.1 : "ymmdd" indicates the file preparation date. y is the year, mm is the month and dd is the date. The IODD file can be downloaded from the SMC Web site (https://www.smcworld.com).

-2No.PS-OMV0003CN-G / *3) 1 1.5 *3)1 1 [] -3No.PS-OMV0003CN-G () () () () -4No.PS-OMV0003CN-G () * UL UL1310 2 UL1585 2 30 Vrms(42.4 V ) (2 ) UL (1 20 ) -5No.PS-OMV0003CN-G * FG (35 N () ,() *() 6 33 () 20 m DC(-)() * ( ) -6No.PS-OMV0003CN-G () CE 0~50(5 ) (FKMHNBR) * 1015 10 1% 1959 LCD * -7No.PS-OMV0003CN-G ISE70 02 L2 M 3 Y K T ISE70 0~1MPa ISE71 0~1.6MPa 02 Rc1/4 N02

M L2 Pressure range Option 3 Symbol Description ISE70 0 to 1 MPa ISE71 0 to 1.6 MPa Symbol Description Nil Operation manual Y None K Operation manual + Calibration certificate Piping specification Symbol Description 02 Rc1/4 N02 NPT1/4 F02 G1/4*1 T Calibration certificate Option 2 Symbol Description Nil None *1 ISO 1179-1 compliant Output specification*1 A Bracket A (Interchangeable with

Pressure Range: ISE71 (0 to 1.6 MPa), Piping: F02 (G 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m)

Pressure Range: ISE71 (0 to 1.6 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type])

Pressure Range: ISE71 (0 to 1.6 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: M (SI Unit Only), Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m)

Pressure Range: ISE71 (0 to 1.6 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m), Bracket: None, Operation Manual/Calibration Certificate: K (Operation Manual

Pressure Range: ISE71 (0 to 1.6 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: None, Operation Manual/Calibration Certificate: Y (None)

Pressure Range: ISE71 (0 to 1.6 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m), Bracket: A (Bracket A, Interchangeable with ISE70)

Bracket A Bracket B [F 0] Display units, switch output specifications and diagnostic information selection function ISE70(G): 0.500 MPa/ISE71: 0.800 MPa/ ISE75G: 1.000 MPa/ISE76G: 2.50 MPa/ ISE77G: 5.00 MPa/ISE78G: 8.00 MPa Pressure setting Cross recessed round head screw: Nominal size M4 x 6L Cross recessed round head screw: Nominal size M4 x 6L Item Default setting ISE70(G): 0.050 MPa/ISE71

RoHS 3-Screen Display High-Precision Digital Pressure Switch: For Air ISE70/71 Series How to Order ISE70 02 M L2 Pressure range Option 3 Symbol Description ISE70 0 to 1 MPa ISE71 0 to 1.6 MPa Symbol Description Nil Operation manual Y None K Operation manual + Calibration certicate Piping specification Symbol Description 02 Rc1/4 N02 NPT1/4 F02 G1/41 T Calibration certicate Option 2 Symbol

Pressure Range: ISE71 (0 to 1.6 MPa), Piping: 02 (Rc 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m), Bracket: B (Bracket B), Operation Manual/Calibration Certificate

Pressure Range: ISE71 (0 to 1.6 MPa), Piping: 02 (Rc 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type])

Pressure Range: ISE71 (0 to 1.6 MPa), Piping: 02 (Rc 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m), Bracket: A (Bracket A, Interchangeable with ISE70)

Pressure Range: ISE71 (0 to 1.6 MPa), Piping: 02 (Rc 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m), Bracket: B (Bracket B)

Pressure Range: 0 to 1.6 MPa, Piping: NPT 1/4, Output Specification: Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type], Unit Specification: -, Lead Wire: -, Bracket: -, Operation Manual/Calibration Certificate: -