3-Screen Display High-Precision Digital Pressure Switch Air 1.0 MPa/1.6 MPa ISE70 ISE71 1.0 MPa/2.0 MPa ISE70G ISE75G RoHS General Fluids 5.0 MPa/10 MPa IP67 ISE76G ISE77G For air Blue It is possible to change the settings while checking the measured value.
Pressure Range: ISE77G (0 to 10 MPa), Piping: N02 (NPT 1/4), Orifice: T (Orifice shipped with the Product), Unit Specification: M (SI Unit Only), Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m), Bracket: A (Bracket A, Interchangeable with ISE75[H])
Pressure Range: ISE77G (0 to 10 MPa), Piping: N02 (NPT 1/4), Orifice: T (Orifice shipped with the Product), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: A (Bracket A, Interchangeable with ISE75[H])
Pressure Range: 0 to 10 MPa, Piping: NPT 1/4, Orifice: Orifice shipped with the Product, Unit Specification: SI Unit Only, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: Bracket A, Interchangeable with ISE75[H], Operation Manual/Calibration Certificate: -
Pressure Range: ISE77G (0 to 10 MPa), Piping: N02 (NPT 1/4), Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m), Bracket: A (Bracket A, Interchangeable with ISE75[H])
Pressure Range: ISE77G (0 to 10 MPa), Piping: F02 (G 1/4, ISO 1179-1 Compliant), Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m), Bracket: A (Bracket A, Interchangeable with ISE75[H])
Pressure Range: ISE77G (0 to 10 MPa), Piping: 02 (Rc 1/4), Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m), Bracket: A (Bracket A, Interchangeable with ISE75[H])
Pressure Range: 0 to 10 MPa, Piping: NPT 1/4, Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: Bracket A, Interchangeable with ISE75[H], Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 10 MPa, Piping: G 1/4, ISO 1179-1 Compliant, Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: Bracket A, Interchangeable with ISE75[H], Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 10 MPa, Piping: Rc 1/4, Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: Bracket A, Interchangeable with ISE75[H], Operation Manual/Calibration Certificate: -
L2 L3 2 x M4 x 0.7 (For 9 stations or more) L2 Note) These figures show the SS5Y3-51S5-05D-C6.
(Note 1) I/O 1 P15R P15R P15R P15R P15R P15R 2 I -/VC VC VC/VLA VLA VLA/3 LG LG LG LG LG LG 4 O LA LA LA LA LA LA 5 O LAR LAR LAR LAR LAR LAR 6 O LB LB LB LB LB LB 7 O LBR LBR LBR LBR LBR LBR 8 O LZ LZ LZ LZ LZ LZ 9 O LZR LZR LZR LZR LZR LZR 10 I PP PP/(Note 6) (Note 6) (Note 6) -/PP PD43/PD44 11 I PG PG/-/PG 12 OPC OPC/-/OPC 13 O (Note 4) (Note 4) (Note 4) (Note 4) (Note 4) (Note 4) PD47
P P/S S S/T T T/P 1 P15R P15R P15R P15R P15R P15R 2 I /VC VC VC/VLA VLA VLA/ 3 LG LG LG LG LG LG 4 O LA LA LA LA LA LA 5 O LAR LAR LAR LAR LAR LAR 6 O LB LB LB LB LB LB 7 O LBR LBR LBR LBR LBR LBR 8 O LZ LZ LZ LZ LZ LZ 9 O LZR LZR LZR LZR LZR LZR 10 I PP PP/ /PP 11 I PG PG/ /PG 12 OPC OPC/ /OPC 13 14 15 I SON SON SON SON SON SON PD03 16 I /SP2 SP2 SP2/SP2 SP2 SP2/ PD04 17 I PC PC/ST1 ST1
LA LA LA LA LA 16 O LAR LAR LAR LAR LAR LAR 17 O LB LB LB LB LB LB 18 O LBR LBR LBR LBR LBR LBR 19 O LZ LZ LZ LZ LZ LZ 20 O LZR LZR LZR LZR LZR LZR 21 O OP OP OP OP OP OP 22 I PG PG/-/PG 23 I PP PP/-/PP 24 I NG NG/-/NG 25 I NP NP/-/NP 26 Note 1.
Abbreviation Connection target (application) Description Supply the following power to L1, L2, L3. For the 1-phase 200 to 230VAC power supply, connect the power supply to L1, L2, and keep L3 open.
Abbreviation Connection target (application) Description Supply the following power to L1, L2, L3. For the 1-phase 200 to 230VAC power supply, connect the power supply to L1, L2, and keep L3 open.
Symbol Connection target (application) Description Supply the following power to L1, L2, and L3. For 1-phase 200 V AC to 240 V AC, connect the power supply to L1 and L3. Leave L2 open. Driver LECSS2-T5 to Power LECSS2-T9 L1/L2/L3 Main circuit power 3-phase 200 V AC to 240 V AC, 50 Hz/60 Hz L1/L2/L3 supply 1-phase 200 V AC to 240 V AC, 50 Hz/60 Hz L1/L3 P3/P4 Connect P3 and P4.
CN3 OPEN 1 11 CN4 CN2L CN2 CN1B CN1A CN3 CN5 2 12 L1 LG LG L2 DI1 DI2 3 13 L3 4 14 N DOCOM MBR P1 MO1 MO2 5 15 P2 6 16 DICOM ALM C P LA LAR 7 17 Connector for the front axis of CN1A SSCNET cable. Connector for the rear axis of CN1B SSCNET cable.
(a) Delta connection For the 3-phase (L1/L2/L3) delta connection, an instantaneous power failure occurs in the voltage between a pair of lines (e.g. between L1 and L2) among voltages between three pairs of lines (between L1 and L2, L2 and L3, or L3 and L1).
H A L2 L1 RZQ Item Load factor n Note MI W S CEP1 1.