L2 AS ASP Metric Size ASN A M1 L5 Max.
M1 M2 Weight (g) ASV310F-N01-07 ASV310F-N01-09 ASV310F-N02-07 ASV310F-N02-09 ASV410F-N01-09 ASV410F-N01-11 ASV410F-N02-09 ASV410F-N02-11 ASV410F-N03-09 ASV410F-N03-11 ASV510F-N02-11 ASV510F-N02-13 ASV510F-N03-11 ASV510F-N03-13 ASV510F-N04-11 ASV510F-N04-13 17.2 19.3 17.2 19.3 19.3 23.3 19.3 23.3 19.3 23.3 23.3 26.5 23.3 26.5 23.3 26.5 73 73.8 73 73.8 83.1 85.2 83.1 85.2 83.1 85.2 90.2 91.9
Then, measurement mode will be displayed. : Within approximately 0.2 sec. after power-on, the switch starts. : ISE78G is not UL approved. Bracket A (Part No.: ZS-50-A) Bracket B (Part No.: ZS-50-B) Thank you for purchasing an SMC ISE70/ISE71/ISE70G/ISE75G/ISE76G/ ISE77G/ISE78G Series High-precision Digital Pressure Switch.
= 10.5n + 56.3 + (Number of ejector units x 26.7) L4 is L2 plus about 30.
(L3) (L4) Vacuum ejector unit style: Equation L1=10.5n+28.7+(number of ejector units X 26.7) L2=10.5n+41.3+(number of ejector units X 26.7) L4 is L2 plus about 30.
Dimensions LLAA--C Stations 4-Mounting hole for W Y Dimensions (mm) A S K Model LLA2A LLA3A LLA4A LLA5A 11.5 L1 24 L2 L3 29 Sensor (Breathing port) U 2-R 34.5 (mm) H G Station 2 3 4 5 Model C Symbol P N L1 L2 L3 L1 L2 L3 L1 L2 L3 L1 L2 L3 62 93 124 155 E V LLA2A 75 106 137 168 Pitch = B A (OUT) port n-Q 118 149 180 211 P (IN) port 2-Q 74 111 148 185 (Max.
Abbreviation Connection target (application) Description Supply the following power to L1, L2, L3. For the 1-phase 200 to 230VAC power supply, connect the power supply to L1, L2, and keep L3 open.
AC200230V AC100120V 40 M5 3.24[Nm] M5 3.24[Nm] 6 AC100120V AC200230V AC100120V AC200230V L1 L1 PE PE L2 2-M5 2-M5 L2 L3 CNP1 CNP1 N N P1 P1 M4 1.2[Nm] P2 P2 M4 1.2[Nm] P P C C CNP2 D CNP2 D L11 L11 L21 L21 U U CNP3 V CNP3 V W W 9 2 9 (2) LECSS-S8 [mm] 5 40 6 6 6 (80) (170) 6 6 () CN4 CN2L CN2 CN1B CN1A CN3 CN5 CNP1 L1 L2 L3 N P1 P2 P C D L11 L21 U V W L1 L2 () L3 N P1 CNP2 P2
(a) Delta connection For the 3-phase (L1/L2/L3) delta connection, an instantaneous power failure occurs in the voltage between a pair of lines (e.g. between L1 and L2) among voltages between three pairs of lines (between L1 and L2, L2 and L3, or L3 and L1).
(a) Delta connection For the 3-phase (L1/L2/L3) delta connection, an instantaneous power failure occurs in the voltage between a pair of lines (e.g. between L1 and L2) among voltages between three pairs of lines (between L1 and L2, L2 and L3, or L3 and L1).
LECSS2-S5 LECSS2-S7 LECSS2-S8 LECSS1-S5 LECSS1-S7 LECSS1-S8 Driver L1 L2 L3 Power supply Main circuit power supply 3-phase 200V to 230VAC, 50/60Hz L1L2L3 1-phase 200V to 230VAC, 50/60Hz L1 L2 1-phase 100V to 120VAC, 50/60Hz L1 L2 When using driver built-in regenerative resistor, connect P( ) and D.
10 9 345 357 369 385 397 409 415 427 439 7 8 310.5 322.5 334.5 346.5 358.5 370.5 373.5 385.5 397.5 6 241.5 253.5 265.5 269.5 281.5 293.5 290.5 302.5 314.5 5 207 219 231 231 243 255 249 261 273 4 172.5 184.5 196.5 192.5 204.5 216.5 207.5 219.5 231.5 3 138 150 162 154 166 178 166 178 190 2 103.5 115.5 127.5 115.5 127.5 139.5 124.5 136.5 148.5 L1 L2 L3 L1 L2 L3 L1 L2 L3 276 288 300 308 320
L3 L1 L2 L3 L1 L2 L3 VXE21 VXE22 VXE23 Manifold construction 2 stations x 1 3 stations x 1 2 stations x 2 2 stations + 3 stations 3 stations x 2 2 stations x 2 + 3 stations 2 stations + 3 stations x 2 3 stations x 3 2 stations x 2 + 3 stations x 2 (mm) Electrical entry W Conduit terminal T DIN terminal T Conduit R Grommet Model A B C D E F H J N X 69.5 72.5 75 Y 100.5 103.5 106 V 39 48.5
Abbreviation Connection target (application) Description Supply the following power to L1, L2, L3. For the 1-phase 200 to 230VAC power supply, connect the power supply to L1, L2, and keep L3 open.
Symbol Connection target (application) Description Supply the following power to L1, L2, and L3. For 1-phase 200 V AC to 240 V AC, connect the power supply to L1 and L3. Leave L2 open. Driver LECSS2-T5 to Power LECSS2-T9 L1/L2/L3 Main circuit power 3-phase 200 V AC to 240 V AC, 50 Hz/60 Hz L1/L2/L3 supply 1-phase 200 V AC to 240 V AC, 50 Hz/60 Hz L1/L3 P3/P4 Connect P3 and P4.
Abbreviation Connection target (application) Description Supply the following power to L1, L2, L3. For the 1-phase 200 to 230VAC power supply, connect the power supply to L1, L2, and keep L3 open.
(d) ( FR-BSF01FR-BLF) () 0.5MHz5MHz [mm] 2(AWG12)) (L1L2L3) (UVW) 4 4 2 FR-BSF01(3.5 (110) 95 0.5 25 (22.5) 11.25 0.5 (65) 33 MC MCCB 1 L1 L2 L3 (65) 4.5 (4 ) 2 2(AWG10)) FR-BLF(5.5 MC MCCB 7 L1 L2 L3 31.5 130 7 85 80 35 (4 ) 160 180 2.3 11 23 11. (e) ( FR-BIF) 10MHz 200V: FR-BIF [mm] FR-BIF 4 mA 300 LECSS2-T MC MCCB 29 L1 42 4 5 L2 L3 29 7 58 44 11 24 11.
P()-D()13.2 3. 13.1 4. 4.8.3 5. 4.10 4 3 4 (2) LECSC-AC200230V ON OFF RA MC MC SK NFB MC CNP1 L1 AC200230V CNP3 (5) U 2 L2 U V 3 L3 V M W 4 N W 1 P1 (1) P2 PE CNP2 P (2) C D (3) CN2 L11 L21 CN6 CN6 DC24V DOCOM EMG (4) DOCOM DICOM (4) ALM RA 1.
Pressure Range: ISE78G (0 to 16 MPa), Piping: N02 (NPT 1/4), Orifice: None
Pressure Range: ISE78G (0 to 16 MPa), Piping: N02 (NPT 1/4), Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m)