Model: Standard, Bar Length: 400mm, Emmiter Cartridge, Material: High Speed De-ionizing Cartridge, Tungsten, High-voltage Cable Length: 3m, One-touch Fitting: ø1/4" Straight, Plug Position: High-voltage Cable Side, Input, Output Specification: Nil (40); NPN (41, 42), Power Supply Cable Length: 3m, Bar Bracket: w/Bracket 2, DIN Rail Bracket for Controller &
High-voltage Power Supply: Controller
Gun Type Ionizer IZG10 Series IZS40/41/42 IZT40/41(-L)/ 42(-L)/43(-L) IZN10E IZF IZG10 ZVB IZD10/IZE11 IZH10 Antistatic Equipment *1 Lightweight 200 g Only *1 Body weight Lighting LED Reduced operating force Easy to hold grip Blow setting function p. 179 Select from continuous blow or pulse blow.
(2 sets) Single solenoid SV1100-5FU (4 sets) SS5V1-16PD1-06B-C6 . 1 set (manifold part no.)
Fittings & Tubing Air Cylinders Rotary Actuators Double solenoid Manifold 10-SS5V1-W10S4VWD-05B-C6 (1 set) 10-SV1200-5FU (3 sets) Single solenoid 10-SV1100-5FU (2 sets) U side Stations D D D D D 10-SS5V1-W10S4VWD-05B-C6 1 set (manifold part no.) 10-SV1100-5FU 2 sets (manifold part no.) 10-SV1200-5FU 3 sets (manifold part no.) 3 2 1 D side How to Order Valve Note) SV 1 1 0 0 F 5 10 Air
SY3140-5FU 3 sets (Single solenoid part no.) SY3245-5FU 1 set (Double solenoid part no.) *For the special specifications, indicate separately on a manifold specification sheet. The asterisk denotes the symbol for assembly. Prefix to the part no. of the solenoid valve, etc.
(2 sets) Manifold SS5V1-16S3AD-06B-C6 (1 set) Single solenoid SV1100-5FU (4 sets) U side D side D D D D D D SS5V1-16S3AD-06B-C61 set (manifold part no.)
SY3140-5FU . 2 sets (Single solenoid part no.) SY3245-5FU . 1 set (Double solenoid part no.) Stations Symbol Note 02 2 Single wiring specification (Up to 20 solenoids applicable) ... ... 20 20 Note 1) Includes the number of blanking plate assemblies.
SV1100-5FU (4 sets) U side SS5V1-W16SA1WD-06B-C6 1 set (manifold part no.)
The X and PE port size of External pilot type (R), and X port size of External pilot, Built-in silencer type (RS) are 4 (mm) or 5/32" (inch) for the SV1000/2000 series, and 6 (mm) or 1/4" (inch) for the SV3000 series. 25 For Series EX600 Series SV How to Order Manifold Assembly Example (SS5V1) 2-position single SV1100-5FU 2-position double SV1200-5FU Digital Output Unit EX600-DYPB Digital
How to Order Valves How to Order Manifold Assemblies Example 4 0 5 SY 3 1 FU Single solenoid 2 position single Supply/Exhaust block (U side mounting) SY3140-5FU (3 sets) Double solenoid 5 FU Double/3 position 5 SY 3 2 4 SY3245-5FU (1 set) Series 3 SY3000 5 SY5000 Type of actuation 2 2 position double 3 3 position closed center 24VDC +COM + 1 2 3 Stations D side U side 4 3 position exhaust
The X and PE port size of External pilot type (R), and X port size of External pilot, Built-in silencer type (RS) are 4 (mm) or 5/32" (inch) for the SV1000/2000 series, and 6 (mm) or 1/4" (inch) for the SV3000 series. 295 For Series EX600 Series SV Directional Control Valves How to Order Manifold Assembly Example (SS5V1) 2-position single SV1100-5FU 2-position double SV1200-5FU Digital Output
Valve part numbers: SY3140, SY5140, SY3140-5FU, SY5140-5FU, etc.
Models include the standard IZT40, the IZT41 which adds auto-balance, emitter maintenance detection, and I/O signals, and the IZT42 with low amplitude ion generation for sensitive electronics. Extending the value of IZT, one controller can manage a maximum of 4 ionizing bars.
This component is available for individual selection as a replacement or to upgrade a system from the standard IZT40 bar system to a system with auto balance and operation feedback, Dual AC, or mixed IZTB bars and IZTN nozzles.
This component is available for individual selection as a replacement or to upgrade a system from the standard IZT40 bar system to a system with auto balance and operation feedback, Dual AC, or mixed IZTB bars and IZTN nozzles.
Models include the standard IZT40, the IZT41 which adds auto-balance, emitter maintenance detection, and I/O signals, and the IZT42 with low amplitude ion generation for sensitive electronics. Extending the value of IZT, one controller can manage a maximum of 4 ionizing bars.
This component is available for individual selection as a replacement or to upgrade a system from the standard IZT40 bar system to a system with auto balance and operation feedback, Dual AC, or mixed IZTB bars and IZTN nozzles.
DIN MOUNTING/ IZT40/41 POWER SUPPLY, IONIZER ACCESSORIES, IZD, IZE, IZH, 865
Model: 40 (Standard), Bar Length: 82 (820mm), Emmiter Cartridge, Material: D (High Speed De-ionizing Cartridge, Tungsten), High-voltage Cable Length: 3 (3m), One-touch Fitting: 8H (ø8 Straight), Plug Position: R (Opposite Side of High-voltage Cable), Input, Output Specification: Nil (40); NPN (41, 42), Power Supply Cable Length: 5 (5m), Bar Bracket: F (w/Bracket 2), DIN Rail Bracket for Controller
Model: 40 (Standard), Bar Length: 130 (1300mm), Emmiter Cartridge, Material: D (High Speed De-ionizing Cartridge, Tungsten), High-voltage Cable Length: 3 (3m), One-touch Fitting: AH (ø10 Straight), Plug Position: w/o Plug, Input, Output Specification: Nil (40); NPN (41, 42), Power Supply Cable Length: 5 (5m), Bar Bracket: F (w/Bracket 2), DIN Rail Bracket for Controller &
High-voltage