VVQ2000-51A-C8 VVQ2000-51A-C10 Note) When replacing a pilot valve assembly only, note that SY114 (G, H, L, M) cannot replace SY115 (DIN terminal) or vice versa.
This is used by mounting it on a manifold block when a valve is removed for maintenance or when it is planned to install an additional valve in the future, etc. 4 2 5 5 5 1 3 1 3 1 3 3 5 1 SUP passage blocking EXH passage blocking SUP/EXH passage blocking Individual SUP spacer Blocking plate (for pilot EXH passage) 02 03 C10 VV71-PAZ503-53A When a valve's pilot valve exhaust effects other
VFS C8, C10 2-Rc 1/8 (PE port) VS4 VQ7 EVS C8: Max. 6.5 C10: Max. 7 6-Rc 1/2 (P, EA, EB port) For wiring specifications, refer to page 3-5-8.
Blanking plate (Filter, Regulator) Blanking plate (Pressure switch) Number of manifold blocks required for mounting (stations) 2 2 2 2 2 2 2 1 Manifold Specifications Porting specifications Manifold block size Applicable solenoid valve Weight (kg) Stations 1(P), 3(R2) 5(R1) port size 2(B), 4(A) port Port location Port size 1/4 3/8 C6 (6) C8 (8) C10 (10) Right, Left Note) 1/4 3/8 C12 (12)
Blanking plate (Filter, Regulator) Blanking plate (Pressure switch) Number of manifold blocks required for mounting (stations) 2 2 2 2 2 2 2 1 Manifold Specifications Porting specifications Manifold block size Applicable solenoid valve Weight (kg) Stations 1(P), 3(R2) 5(R1) port size 2(B), 4(A) port Port location Port size 1/4 3/8 C6 (6) C8 (8) C10 (10) Right, Left Note) 1/4 3/8 C12 (12)
to Order (Manifold) 5 03R 04D Q VV72 E Stations Air release valve Piping/P, R1, R2 Port Air release valve/Voltage Piping/A, B port Silencer box (Bottom) 1 2 (Top) 1 2 (Both sides) 1 2 (Bottom) 3 4 (Top) 3 4 (Both sides) 3 4 (Right) 3 8 (Right) 1 2 (Left) 3 8 (Left) 1 2 (Bottom) 3 8 (Bottom) 1 2 Combination Without air release valve 1 1 Without air release valve With air release valve 04D 04U
Applicable pad 04U/06U/08U Applicable pad 10U/16U Applicable pad 25U/32U Applicable pad 40U/50U 4.9 30 R 30 R R 25 30 R R R R 10.5 9.5 2 8 9 25 R 2 0.5 6 7 7 8 R R R R R R 45 45 45 2.7 1 R R 2.5 4.5 5 6.6 R 2.5 3.8 4.9 3.5 5 6 7.9 R 4.5 8 9 11.7 11.7 Note) R part has to be smooth with no corners.
Applicable pad 04U/06U/08U Applicable pad 10U/16U Applicable pad 25U/32U Applicable pad 40U/50U 4.9 30 R 30 R R 25 30 R R R R 10.5 9.5 2 8 9 25 R 2 0.5 6 7 7 8 R R R R R R 45 45 45 2.7 1 R R 2.5 4.5 5 6.6 R 2.5 3.8 4.9 3.5 5 6 7.9 R 4.5 8 9 11.7 11.7 Note) R part has to be smooth with no corners.
Series: 5 (JSY5000), Type: 10S (Side-Ported, Serial Interface, EX250), SI Unit: 0 (w/o SI Unit), Input Block Stations: None, Input Block Type: w/o Input Block, Valve Stations: 8 Stations, P,E Port, SUP/EXH Assembly: U (Internal Pilot, U Side, 2 to 10 Stations), A,B Port Size: C10 (ø10 One-touch Fitting)
Series: 5 (JSY5000), Type: 10S (Side-Ported, Serial Interface, EX250), SI Unit: 0 (w/o SI Unit), Input Block Stations: None, Input Block Type: w/o Input Block, Valve Stations: 16 Stations, P,E Port, SUP/EXH Assembly: B (Internal Pilot, Both Sides, 2 to 24 Stations), A,B Port Size: C10 (ø10 One-touch Fitting)
Series: 5 (JSY5000), Type: 10S (Side-Ported, Serial Interface, EX250), SI Unit: 0 (w/o SI Unit), Input Block Stations: None, Input Block Type: w/o Input Block, Valve Stations: 4 Stations, P,E Port, SUP/EXH Assembly: B (Internal Pilot, Both Sides, 2 to 24 Stations), A,B Port Size: C10 (ø10 One-touch Fitting)
Series: 5 (JSY5000), Type: 10S (Side-Ported, Serial Interface, EX260), SI Unit: 0 (w/o SI Unit), SI Unit Output Polarity: NPN, Positive Common, Valve Stations: 5 Stations, P,E Port Location: B (Both Sides, 2 to 24 Stations), SUP/EXH Block: S (Internal Pilot, Built-in Silencer), A,B Port Size: C10 (ø10 One-touch Fitting)
Series: JSY5000, Type: Side-Ported, Serial Interface, EX250, SI Unit: w/o SI Unit, Input Block Stations: None, Input Block Type: w/o Input Block, Valve Stations: 8 Stations, P,E Port, SUP/EXH Assembly: Internal Pilot, U Side, 2 to 10 Stations, A,B Port Size: ø10 One-touch Fitting, Mounting: -, DIN Rail Option: -
Series: JSY5000, Type: Side-Ported, Serial Interface, EX250, SI Unit: w/o SI Unit, Input Block Stations: None, Input Block Type: w/o Input Block, Valve Stations: 16 Stations, P,E Port, SUP/EXH Assembly: Internal Pilot, Both Sides, 2 to 24 Stations, A,B Port Size: ø10 One-touch Fitting, Mounting: -, DIN Rail Option: -
Series: JSY5000, Type: Side-Ported, Serial Interface, EX250, SI Unit: w/o SI Unit, Input Block Stations: None, Input Block Type: w/o Input Block, Valve Stations: 4 Stations, P,E Port, SUP/EXH Assembly: Internal Pilot, Both Sides, 2 to 24 Stations, A,B Port Size: ø10 One-touch Fitting, Mounting: -, DIN Rail Option: -
Series: 5 (JSY5000), Type: 10 (Side-Ported), Connector Type: T (Terminal Block Box), Valve Stations: 4 Stations, P,E Port Location: U (U Side, 2 to 10 Stations), SUP/EXH Block: Internal Pilot, A,B Port Size: C10 (ø10 One-touch Fitting)
Series: JSY5000, Type: Side-Ported, Connector Type: Terminal Block Box, Valve Stations: 4 Stations, P,E Port Location: U Side, 2 to 10 Stations, SUP/EXH Block: Internal Pilot, A,B Port Size: ø10 One-touch Fitting, Mounting: -, DIN Rail Option: -
Valve for JJ5SY5-H manifold. Available as 2-position single and double, 3-position, 4-position dual 3-port. Voltage: 24 VDC; Pilot type: internal and external; Flow rate: 1,600 L/min (ANR); Power consumption: 0.4W (0.1W with power-saving circuit)
Valve for JJ5SY5-H manifold. Available as 2-position single and double, 3-position, 4-position dual 3-port. Voltage: 24 VDC; Pilot type: internal and external; Flow rate: 1,600 L/min (ANR); Power consumption: 0.4W (0.1W with power-saving circuit)
AL Dimensions DXT334-X72-04R-04U L side U side D side Exhaust port R side Rc 1/2 supply port (L side) 2-Rc 1/2, Output port 14-9-23