KK2P-23E -04E -06E KK3P-04E -06E -08E -10E KK4P-06E -08E -10E -12E KK6P-12E -16E KK2S-23E -04E -06E KK3S-04E -06E -08E -10E KK4S-06E -08E -10E -12E KK6S-12E -16E 3.2 4 6 4 6 8 10 6 8 10 12 12 16 3.2 4 6 4 6 8 10 6 8 10 12 12 16 M5 M5 1/8 1/8 1/4 1/4 1/2 1/2 15-2-76 5 S Couplers General Purpose Type Series KK Specifications K M Fluid Air/Water (Standard industrial water) KK2: 100kPa to 1.0MPa
Body size Part no. 4 6 8 10 6 8 10 12 12 16 4 6 8 10 6 8 10 12 12 16 KK3P-04E -06E -08E -10E KK4P-06E -08E -10E -12E KK6P-12E -16E KK3S-04E -06E -08E -10E KK4S-06E -08E -10E -12E KK6S-12E -16E 1/8 1/8 1/4 1/4 1/2 1/2 2 S Couplers Series KK Specifications Fluid Air, Water (standard industrial water) 0 to 1.0MPa Operating pressure range Proof pressure 1.5MPa Ambient and fluid temperature 5
KK3S-04E -06E -08E -10E KK4S-06E -08E -10E -12E KK6S-12E -16E 4 6 8 10 6 8 10 12 12 16 4 6 8 10 6 8 10 12 12 16 KK3P-04E -06E -08E -10E KK4P-06E -08E -10E -12E KK6P-12E -16E 1/8 1/8 1/4 1/4 1/2 1/2 61 &RXUWHV\RI6WHYHQ(QJLQHHULQJ,QF5\DQ:D\6RXWK6DQ)UDQFLVFR&$ *HQHUDO Series KK Specifications Fluid Air, Water (standard industrial water) Operating pressure range 0 to 1.0MPa Proof pressure 1.5MPa
Body size Part no. 4 6 8 10 6 8 10 12 12 16 4 6 8 10 6 8 10 12 12 16 KK3P-04E -06E -08E -10E KK4P-06E -08E -10E -12E KK6P-12E -16E KK3S-04E -06E -08E -10E KK4S-06E -08E -10E -12E KK6S-12E -16E 1/8 1/8 1/4 1/4 1/2 1/2 2 S Couplers Series KK Specifications Fluid Air, Water (standard industrial water) 0 to 1.0MPa Operating pressure range Proof pressure 1.5MPa Ambient and fluid temperature 5
Flow characteristics 11,000 Series KK6 (KK6S-04MS+KK6P-04MS) 10,000 9,000 8,000 Flow rate (l/min(ANR)) 7,000 6,000 Series KK4 (KK4S-02MS+KK4P-02MS) 5,000 4,000 Series KK3 (KK3S-01MS+KK3P-01MS) Light weight The weight is minimized by adoption of stamped parts and resin parts as will as miniaturization of the body. 3,000 2,000 1,000 0 0.2 0 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 0.1 Pressure (MPa) PAT
CE2 A/B phase difference output Output signal 500 VDC, 50 M or more (between case and 12E) Insulation resistance ML2B Symbol Specifications 33.3 Hz 6.8 G 2 hrs. each in X, Y directions 4 hrs. in Z direction based upon JIS D 1601 Vibration resistance -XC22 Fluoro rubber seals C J G5-S Impact resistance 30 G 3 times each in X, Y, Z directions Enclosure IP-67 (IEC Standard)(2) CV CE1-R 5 m,
CE2 A/B phase difference output Output signal 500 VDC, 50 M or more (between case and 12E) Insulation resistance ML2B Symbol Specifications 33.3 Hz 6.8 G 2 hrs. each in X, Y directions 4 hrs. in Z direction based upon JIS D 1601 Vibration resistance -XC22 Fluoro rubber seals C J G5-S Impact resistance 30 G 3 times each in X, Y, Z directions Enclosure IP-67 (IEC Standard)(2) CV CE1-R 5 m,
ripple: 1% or less) Current consumption 40 mA Foot Note 1) Flange Bore size (mm) Double clevis Resolution 0.1 mm/pulse 0.2 mm (at 20C) (1) Accuracy 12 20 32 40 50 63 CQ-L012 CQ-F012 CQ-D012 Output type Open collector (24 VDC, 40 mA) CQ-L020 CQ-F020 CQ-D020 Output signal A/B phase difference output CQ-L032 CQ-F032 CQ-D032 50 M or more (500 VDC measured via megohmmeter) (between case and 12E
CE2 A/B phase difference output Output signal 500 VDC, 50 M or more (between case and 12E) Insulation resistance ML2B Symbol Specifications 33.3 Hz 6.8 G 2 hrs. each in X, Y directions 4 hrs. in Z direction based upon JIS D 1601 Vibration resistance -XC22 Fluoro rubber seals C J G5-S Impact resistance 30 G 3 times each in X, Y, Z directions Enclosure IP-67 (IEC Standard)(2) CV CE1-R 5 m,
) DC500V50M (12E ) 33.3Hz6.8G XY 2 Z 4 JIS D1061 30G XYZ 3 IP65
Response Speed 500mm/s (sensor : 1500mm/s) Proof Voltage AV500V, 1 min (Case to 12E) Insulation Resistance DC500V, above 50M (Case to 12E) Shock Resistance 33.3Hz6.8G, 2hours at X,Y and 4hours at Z JIS D1061 as standard Impact Resistance 30G, 3 times at each axis Extension Cable 5m, 10m, 15m, 20m (Option) (Connector : R03-J8M, Tajimi Musen Denki Company) 23 Chapter 6: Model 6-1 Hyrodless
Magnetic scale rod, sensor head
(Case to 12E) Insulation Resistance DC500V above 50MV (Case to 12E) Shock Resistance 33.3 3HZ6. 8G. 2 hours at X. Y and 4 hours at Z JIS D1061 as standard Impact Resistance 30G. 3 times at each axis Extension Cable (option) 5m, 10m, 15m, 20m (Connector: R04-P8F7. 3.
(Case to 12E) Insulation Resistance DC500V above 50MV (Case to 12E) Shock Resistance 33.3 3HZ6. 8G. 2 hours at X. Y and 4 hours at Z JIS D1061 as standard Impact Resistance 30G. 3 times at each axis Extension Cable (option) 5m, 10m, 15m, 20m (Connector: R04-P8F7. 3.
Type: Standard, Body Material: C36000 Brass, Compatible Fluid: Water / Air, Valve Structure: Single Passage Opening/Closing, Thread Type: With One-Touch Couplings, Operating Environment Application: Standard, Size of Body: 1/4, Applicable Tube O.D.(mm): 12, With or Without Check Valve: Yes
Type: Standard, Body Material: C36000 Brass, Compatible Fluid: Water / Air, Male/Female: Plug, Valve Structure: Single Passage Opening/Closing, Thread Type: With One-Touch Couplings, Operating Environment Application: Standard, Size of Body: 1/4, Applicable Tube O.D.(mm): 12, With or Without Check Valve: No
Type: Standard, Body Material: C36000 Brass, Compatible Fluid: Water / Air, Male/Female: Plug, Valve Structure: Single Passage Opening/Closing, Thread Type: With One-Touch Couplings, Operating Environment Application: Standard, Size of Body: 1/2, Applicable Tube O.D.(mm): 12, With or Without Check Valve: No
Type: Standard, Body Material: C36000 Brass, Compatible Fluid: Water / Air, Valve Structure: Single Passage Opening/Closing, Thread Type: With One-Touch Couplings, Operating Environment Application: Standard, Size of Body: 1/4, Applicable Tube O.D.(mm): 12, With or Without Check Valve: Yes
Type: Standard, Body Material: C36000 Brass, Compatible Fluid: Water / Air, Male/Female: Plug, Valve Structure: Single Passage Opening/Closing, Thread Type: With One-Touch Couplings, Operating Environment Application: Standard, Size of Body: 1/4, Applicable Tube O.D.(mm): 12, With or Without Check Valve: No
Type: Standard, Body Material: C36000 Brass, Compatible Fluid: Water / Air, Male/Female: Plug, Valve Structure: Single Passage Opening/Closing, Thread Type: With One-Touch Couplings, Operating Environment Application: Standard, Size of Body: 1/2, Applicable Tube O.D.(mm): 12, With or Without Check Valve: No