There were no hits with the full part number, but there were 3 hits in the keyword search.
Product Information » New Products Search Results
, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com A P P SMC SMC R2 R1 R1 R2 VZS Rc 3/8 (Right side only) Reverse pressure spacer AXT502-21A-1 2-3/8 R1, R2 individual EXH spacer: VV71-R2-03 2-1/2, 3/8, C12 Individual EXH spacer: VV71-R2-1/2, 3/8, C10 Individual SUP spacer: VV71-PDouble check
) 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) X X X X X 1.2-72
SYJ7000: 8 mm JIS Symbol 2 position double 2 position single 3 position closed center 3 position exhaust center 3 position pressure center Body ported (A) 4 (B) 2 (A) 4 (A) 4 (B) 2 (A) 4 (A) 4 (B) 2 (B) 2 (B) 2 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) X X X X X 1-5-72 73 Series SYJ5000/7000 Made to Order Specifications: DIN Terminal
Exhaust center VZS 20 or less 0.43 VFS2400 VFS2410 600 Pressure center VFS 0.43 20 or less VFS2500 VFS2510 600 Double check 25 or less 0.6 VFS2600 VFS2610 600 VS4 Note 1) Based on JIS B 8375 (Once per 30 days) for the minimum operating frequency.
Wall Note) For air-cooled type, leave a space of at least 600 mm between the heat exhausting surface and the wall. For water-cooled type, leave a space at least 600 mm between the facility water piping side and the wall. Leave at least 600 mm on the sides indicated with .
Flow Control Equipment Pressure Switches/ Pressure Sensors 3(R2) 1 (P) (R1)5 3 position pressure center i 2(B) (A)4 5 (R1) 1 (P) 3 (R2) 3(R2) 1 (P) (R1)5 (This figure shows a closed center type.)
] 63.4 56 49.5 R1 P R2 R1 P R2 R1 P R2 10 10 10 10 10 10 28 28 28 14 14 14 5 5 5 28.5 28.5 28.5 35.6 35.6 35.6 Refer to page 563 for dimensions with connector cable. 501 10-SYJ3000 4/5 port solenoid valve Series 2 position double [ ]: AC G H Grommet (G), (H): 10-SYJ3243-M5 M5 x 0.8 (A, B port) 10 5 10 2-3.2 (For mounting) 22 2.5 Manual override 11 34.4 G: Approx. 300 H: Approx. 600 (Lead
) 1 (P) 5 (R1) 3 (R2) e q w q w (A) 4 (B) 2 (A) 4 (B) 2 VQ5200 VQ5201 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) e r q w e r q w (A) 4 (B) 2 (A) 4 (B) 2 VQ5301 VQ5401 (A) 4 (B) 2 (A) 4 (B) 2 VQ5300 VQ5400 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) (A) 4 (B) 2 VQ5500 (A) 4 (B) 2 VQ5501 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) Component Parts Component Parts
Port Symbol Caution VF1000 VF3000 VF5000 Supply P P (SUP) P Cylinder A, B A (CYL2) B (CYL1) A, B Connector R1 (EXH2) R2 (EXH1) R1, R2 EXH outlet EA, EB Lead wire JIS symbol Single solenoid Socket Hook 1: P (SUP) 2: B (CYL.1) 3: R2 (EXH.1) 4: A (CYL.2) 5: R1 (EXH.2) 1: P 2: B 3: R2 4: A 5: R1 Plug Connector Lead Wire Length 1: P 4: A 2: B 5: R1 3: R2 Standard length is 300 mm, but the following
) 1 (P) 5 (R1) 3 (R2) VQD Manual override 2 position double 3 position exhaust center (A) 4 (B) 2 (A) 4 (B) 2 Metal Rubber Nil: Non-locking push type (Tool required) B: Slotted locking type (Tool required) 4 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) 2 2 position double 3 position pressure center (A) 4 (B) 2 (A) 4 (B) 2 5 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) 3 position double check (A) 4
) 4 (B) 2 3 (R2) 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) Note) Except VQZ1000 and metal seal type.
80 600/130 800/180 200 V 800/40 1600/80 1600/80 2400/130 3200/180 * The inrush current of the heater flows for several tens of seconds when using 100 V, while it flows for several seconds when using 200 V.
1 (P) (A) 4 (B) 2 3 position exhaust center (A) 4 (B) 2 5 (R1) 3 (R2) 1 (P) 3 position pressure center (A) 4 (B) 2 i 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) 1 (P) (This figure shows a closed center type.)
Specifications Model LEJS40 LEJS63 Stroke [mm] Note 1) 200, 300, 400, 500, 600, 700, 800 900, 1000, 1200 300, 400, 500, 600, 700, 800, 900 1000, 1200, 1500 Work load [kg] Note 2) Horizontal 15 30 55 30 45 85 LEF Vertical 3 5 10 6 10 20 Up to 500 1800 1200 600 LEJ 1800 1200 600 501 to 600 1580 1050 520 601 to 700 1170 780 390 LEL 701 to 800 910 600 300 1390 930 460 801 to 900 720 480 240 1110
Plug A Plug A B B Single Number of R1 P R1 P R2 R2 solenoids Plug A Plug A B B Double R1 P R1 P R2 R2 How to Use Plug Connector Insertion/Removal of Connector InsertionPush the connector straight on to the pins of the solenoid, making sure the lip of the lever securely "locks" into the groove of the solenoid cover.
(Values at the initial period) 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) 3 position pressure center (A) 4 (B) 2 1 (P) 5 (R1) 3 (R2) 3-10-7 8 Series VQ7-6 DIN Terminal Type 2 position single : VQ7-6-FG-S single (Reverse pressure): VQ7-6-YZ-S 120.5 120.5 68.5 52 68.5 Mounting hole 2-6.5 50 50 42.5 42.5 25 25 13 (A port) 13 (B port) Manual override (R1, R2) 2-3/8 P R2 R1 A B 14 11 50 62 12 9 62
VVZS2000-22A-1 VVZS2000-22A-2 VFN G L M KZ D Cylinder side pressure (P2) Check valve Applicable valve model VZS2450-FZ VZS24504(A) 2(B) 3(R2) 5(R1) 3(R2) 5(R1) 3(R2) 5(R1) 100 Ncm3/ min or less Solenoid one side 1(P) de-energized Leakage (Supply pressure: 0.5 MPa 100 Ncm3/ min or less Solenoid both sides de-energized 1(P) Piston SUP side pressure (P1) SUP side pressure P1 (MPa) 0 Operating