Your search for LEY16 returned 30 result(s)
There were no hits with the full part number, but there were 14 hits in the keyword search.
There were no hits with the full part number, but there were 5 hits in the keyword search.
Product Information » New Products Search Results
Size: 16, Motor Mounting Position: Top, Motor: A [Servo Motor (24 VDC)], Lead Screw: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 200mm, Motor Option: None, Rod End Thread: M (Male), Mounting: L (Foot), Actuator Cable: R (Robotic Flexible Cable), Actuator Cable Length: 3 (3m), Controller Type - LEC, JXC: 6N (LECA6, NPN, Step Data Input Type), I/O Cable Length for LEC: 3 (3m
Size: 16, Motor Mounting Position: Top, Motor: A [Servo Motor (24 VDC)], Lead Screw: Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm, Stroke: 200mm, Motor Option: None, Rod End Thread: Male, Mounting: Foot, Actuator Cable: Robotic Flexible Cable, Actuator Cable Length: 3m, Controller Type - LEC, JXC: LECA6, NPN, Step Data Input Type, I/O Cable Length for LEC: 3m, Controller Mounting: DIN Rail
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, ACTUATOR, ELECTRIC, SLIDER, ACTUATOR, ELECTRIC ACTUATOR, GC, 16MM LE ELECTRIC ACTUATOR, 4.62970 lb, ModelActuator specificationsElectric specificationsLock unit specificationsStroke [mm] Note 1)Work load [lb] Note 2)Pushing force [lbf] Note 3) 4)Speed [mm/s]Max. acceleration/deceleration[mm/s2]Pushing
Since 48% of the fresh water discharge rate is equivalent to 200ml/min in the required specifications, 200ml/min 0.48 = approximately 420ml/min, indicating that a discharge rate of 420ml/min is required for fresh water. 3. Finally, find the pilot air pressure and pilot air consumption based on viewing of the flow rate characteristics.
Since 48% of the fresh water discharge rate is equivalent to 200ml/min in the required specifications, 200ml/min 0.48 = approximately 420ml/min, indicating that a discharge rate of 420ml/min is required for fresh water. 3. Finally, find the pilot air pressure and pilot air consumption based on viewing of the flow rate characteristics.
Since 48% of the fresh water discharge rate is equivalent to 200ml/min in the required specifications, 200ml/min 0.48 = approximately 420ml/min, indicating that a discharge rate of 420ml/min is required for fresh water. 3. Finally, find the pilot air pressure and pilot air consumption based on viewing of the flow rate characteristics.
SpeedWork Load Graph (Guide) For Servo Motor (24 VDC) LECA6 Horizontal Vertical LEY16Am LEY16Am 15 15 Lead 2.5: LEY16AC Horizontal work load [kg] 12 12 Vertical work load [kg] 9 9 8 Lead 2.5: LEY16AC Lead 5: LEY16AB 6 6 Lead 5: LEY16AB 4 Lead 10: LEY16AA 3 3 Lead 10: LEY16AA 2 0 0 0 300 200 400 100 500 600 0 300 200 400 100 500 600 Speed [mm/s] Speed [mm/s] LEY25Am LEY25Am 40 40 Horizontal
Main Body Peripheral Component: Peripheral Components, Input Power Supply: DC 24V, Position Detection: Incremental, I/O Module: NPN, Motor Type: Servo motor (24 V DC), Step data (points): 64, Actuator/cable type: LEY16AA-150, I/O cable length / communication plug(m): 1.5, Controller/driver mounting method: Screw mounting type
Main Body Peripheral Component: Peripheral Components, Input Power Supply: DC 24V, Position Detection: Incremental, I/O Module: NPN, Motor Type: Servo motor (24 V DC), Step data (points): 64, Actuator/cable type: LEY16AA-50, I/O cable length / communication plug(m): Without I/O cable, Controller/driver mounting method: Screw mounting type
Main Body Peripheral Component: Peripheral Components, Input Power Supply: DC 24V, Position Detection: Incremental, I/O Module: PNP, Motor Type: Servo motor (24 V DC), Step data (points): 64, Actuator/cable type: LEY16AA-100, I/O cable length / communication plug(m): 3, Controller/driver mounting method: Screw mounting type
Main Body Peripheral Component: Peripheral Components, Input Power Supply: DC 24V, Position Detection: Incremental, I/O Module: PNP, Motor Type: Servo motor (24 V DC), Step data (points): 64, Actuator/cable type: LEY16AA-100, I/O cable length / communication plug(m): Without I/O cable, Controller/driver mounting method: Screw mounting type
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting
Size: 32, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: B (Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm), Stroke: 200mm, Motor Option: None, Rod End Thread: M (Male), Mounting: L (Foot)
Size: 40, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: B (Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm), Stroke: 200mm, Motor Option: None, Rod End Thread: M (Male), Mounting: L (Foot)
Size: 25, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 200mm, Motor Option: None, Rod End Thread: M (Male), Mounting: L (Foot)
Accuracy: Basic Type, Size: 25, Motor Mounting Position: R (Right Side Parallel), Motor Type: NZ (Mounting Type Z), Lead Screw: B [LEY25, 6mm; LEY32, 8mm, (10); LEY63, 10mm], Stroke: 200mm, Dust/Drip Proof: Size 25, 32: w/o Enclosure; Size 63: IP5x, Dust Proof Specification, Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut Included), Mounting: L (Foot)