Your search for LEY16 returned 30 result(s)
There were no hits with the full part number, but there were 14 hits in the keyword search.
There were no hits with the full part number, but there were 5 hits in the keyword search.
Product Information » New Products Search Results
Size: 16, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 250mm, Motor Option: None, Rod End Thread: M (Male), Mounting: Both Ends Tapped (Standard), Actuator Cable: R (Robotic Flexible Cable), Actuator Cable Length: 3 (3m), Controller Type - LEC, JXC: 6N (LECA6, NPN, Step Data Input Type), I/O Cable Length
Size: 16, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm, Stroke: 250mm, Motor Option: None, Rod End Thread: Male, Mounting: Both Ends Tapped (Standard), Actuator Cable: Robotic Flexible Cable, Actuator Cable Length: 3m, Controller Type - LEC, JXC: LECA6, NPN, Step Data Input Type, I/O Cable Length for LEC: 1.5m, Controller
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, ACTUATOR, ELECTRIC, SLIDER, ACTUATOR, ELECTRIC ACTUATOR, GC, 16MM LE ELECTRIC ACTUATOR, .00000 lb, Stroke [mm]Model3050100150200250300350400450500Manufacturable stroke range [mm]LEY16PPPPPPP????10 to 300
Size: 16, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 250mm, Motor Option: None, Rod End Thread: M (Male), Mounting: D (Double Clevis), Actuator Cable: S (Standard Cable), Actuator Cable Length: 3 (3m), Controller Type - LEC, JXC: 1N (LECP1, NPN, Programless Type), I/O Cable Length for LEC: 3 (3m)
Size: 16, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm, Stroke: 250mm, Motor Option: None, Rod End Thread: Male, Mounting: Double Clevis, Actuator Cable: Standard Cable, Actuator Cable Length: 3m, Controller Type - LEC, JXC: LECP1, NPN, Programless Type, I/O Cable Length for LEC: 3m, Controller Mounting: -, Communication
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, ACTUATOR, ELECTRIC, ACTUATOR, ELECTRIC ACTUATOR, GC, 16MM LE ELECTRIC ACTUATOR, 2.97623 lb
Make sure workpieces mounted on the table do not interfere with other workpieces or the facilities around the table. *3 Position after returning to origin *4 [ ] for when the direction of return to origin has changed [mm] Model L A B n D E Without lock With lock LEFS40Em-150m 506 555 156 328 4 150 LEFS40Em-200m 556 605 206 378 6 2 300 LEFS40Em-250m 606 655 256 428 6 2 300 LEFS40Em-300m
SpeedWork Load Graph (Guide) For Step Motor (Servo/24 VDC) LECP6, LECP1, LECPMJ Horizontal Vertical LEY16m LEY16m for acceleration/deceleration: 2000 mm/s2 10 40 Lead 2.5: LEY16C 35 Horizontal work load [kg] Lead 2.5: LEY16C 8 Vertical work load [kg] 30 15 17 20 23 25 Lead 5: LEY16B 5 Lead 5: LEY16B 4 Lead 10: LEY16A 10 6 2 Lead 10: LEY16A 5 0 0 0 300 200 400 100 500 600 0 300 200 400 100
[] 14096 X (1) ()1 ()1 11 800 1 (2) ()1 ()2 1600 1 (3) ()2 ()1 400 1 ()1 ()1 0 1 4097 4096 1 2 1 [] 1 LEY16C-300 2.5mm 1/1 2 LEY16B-300 5mm 25/50 3 LEY16A-300 10mm 25/100 14096 X 12 1 800 2.5mm 2 3 =1 /2 3 =2.5mm/5mm (2.5mm/10mm) =25/50 (25/100) 1) 50 No.SFOD-OMT0009CN-B 7.3 XX X 1CW X 1 2 2CCW 1 XX 1 2 2 1) XX 1) XX 1) XX 0 XX 02 1a 2b 21 1)
[] (1) ():1 ():1 Undefined No.11 1 4096 X 800 1 (2) ():1 ():2 1600 1 (3) ():2 ():1 400 1 ):1 ():1 01 40974096 1 1 [] 1 LEY16C-300 2.5mm 1/1 2 LEY16B-300 5mm 25/50 3 LEY16A-300 10mm 25/100 1 800 2.5mm Undefined No.12 1 4096 X 2 3 =1 /2 (3 ) =2.5mm/5mm (2.5mm/10mm) =25/50 (25/100) 1 -50No.JXC-OMT0001CN-C 9.3 XX X () 1:CW 2:CCW X ORIG direction 1 2 1 2: XX ORIG
Setting of response delay time Set range is 0 to 250m sec. to Communication range (simple communication protocol) Setting and checking 23. Press the [SEL] key once. The set screen of communication range (simple communication protocol) is displayed on the digital display. PV SV 24.
Table 5.3-12 List of set values Set values Explanation Initial value (Default setting) Setting/checking are not available unless the serial protocol setting is simple communication protocol. to Setting of response delay time Set range is 0 to 250m sec. Communication range (simple communication protocol) Setting and checking 23. Press the [SEL] key once.
Cylinder (Tube) Inner Diameter(φ): 4", Stroke(mm): 2 1/2", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.4, Specification: Built-in Magnet, Support bracket: Screw Clearance Hole, Rear Mount, Body
Cylinder (Tube) Inner Diameter(φ): 1 1/16", Stroke(mm): 2 1/2", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.4, Specification: Without Built-in Magnet, Support bracket: Both Ends Tapped, Body Options
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting
Cylinder (Tube) Inner Diameter(φ): 1 1/16", Stroke(mm): 2 1/2", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.4, Specification: Built-in Magnet, Support bracket: Both Ends Tapped, Body Options: Male