Your search for LEY16 returned 30 result(s)
There were no hits with the full part number, but there were 14 hits in the keyword search.
There were no hits with the full part number, but there were 5 hits in the keyword search.
Product Information » New Products Search Results
Size: 16, Motor Mounting Position: D (In-line Type), Motor: Step Motor (Servo 24 VDC), Lead Screw: B (Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm), Stroke: 50mm, Motor Option: None, Rod End Thread: Female, Mounting: F (Rod Flange)
Size: 16, Motor Mounting Position: In-line Type, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm, Stroke: 50mm, Motor Option: None, Rod End Thread: Female, Mounting: Rod Flange, Actuator Cable: -, Actuator Cable Length: -, Controller Type - LEC, JXC: -, I/O Cable Length for LEC: -, Controller Mounting: -, Communication Plug Connector or I/O Cable
VNB1 -6A, 8A, 10A VNB2 -10A, 15A VNB3 -20A VNB5 -32A, 32F VNB6 -40A, 40F VNB7 -50A, 50F VNB4 -25A VNB54 -32A, 32F VNB64 -40A, -40F VNB74 -50A, 50F No.
Size: 16, Motor Mounting Position: D (In-line Type), Motor: Step Motor (Servo 24 VDC), Lead Screw: B (Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm), Stroke: 30mm, Motor Option: None, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: R (Robotic Flexible Cable), Actuator Cable Length: 5 (5m), Controller Type - LEC, JXC: 6P (LECA6, PNP, Step Data Input Type), I/O
Size: 16, Motor Mounting Position: D (In-line Type), Motor: Step Motor (Servo 24 VDC), Lead Screw: B (Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm), Stroke: 50mm, Motor Option: None, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: R (Robotic Flexible Cable), Actuator Cable Length: 5 (5m), Controller Type - LEC, JXC: 6P (LECA6, PNP, Step Data Input Type), I/O
Size: 16, Motor Mounting Position: In-line Type, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm, Stroke: 30mm, Motor Option: None, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: Robotic Flexible Cable, Actuator Cable Length: 5m, Controller Type - LEC, JXC: LECA6, PNP, Step Data Input Type, I/O Cable Length for LEC:
Size: 16, Motor Mounting Position: In-line Type, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm, Stroke: 50mm, Motor Option: None, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: Robotic Flexible Cable, Actuator Cable Length: 5m, Controller Type - LEC, JXC: LECA6, PNP, Step Data Input Type, I/O Cable Length for LEC:
Size: 16, Motor Mounting Position: In-line Type, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm, Stroke: 50mm, Motor Option: None, Rod End Thread: Female, Mounting: Body Bottom Tapped, Actuator Cable: Robotic Flexible Cable, Actuator Cable Length: 5m, Controller: PNP Controller, I/O Cable Length: 3m, Communication Plug Connector: None, Controller
Refer to Table w to select the port size of the screw-in styles (6A to 50A) and flanges (32F to 50F).
VNB1 -6A, 8A, 10A VNB2 -10A, 15A VNB3 -20A VNB5 -32A, 32F VNB6 -40A, 40F VNB7 -50A, 50F VNB4 -25A VNB54 -32A, 32F VNB64 -40A, -40F VNB74 -50A, 50F No.
Screw-in type (6A to 50A) and the flange (32F to 50F) are standardized.
1 50F (10C) 68F (20C) 86F (30C) Standard model Set dew point (Normal operation) Accumulated running hours display Helps maintenance control of the dryer. Gives notice of the maintenance timing etc. 1. Energy saving operation (ECO LED is ON green): Dew point can be set manually between 50 to 86F(10 to 30C). 2. Normal operation (ECO LED is OFF): Dew point is fixed to 50F (10C).
Description VNC1 -6A, 8A, 10A VNC2 -10A, 15A VNC3 -20A VNC4 -25A VNC5 -32A, 32F VNC6 -40A, 40F VNC7 -50A, 50F No.
Refrigerant AFF AM UL certified product Improved corrosion resistance with the use of stainless steel, plate type heat exchanger (IDFB4E to 75E) AMD Power supply voltage: Single-phase 115 VAC (60 Hz) 230 VAC (60 Hz) Three-phase 460 VAC (60 Hz) AMH AME Air flow capacity SCFM (m3/h [ANR]) Series Rated inlet condition Port size Outlet air pressure dew point Note) AMF 37F(2.8C) 45F(7.2C) 50F(
Note 1) Use a 15% ethylene glycol aqueous solution if operating in a place where the ambient temperature and/or circulating fluid temperature is 50F (10C) or less. Note 2) Use fluid in condition below as the circulating fluid.
Description VNC1 -6A, 8A, 10A VNC2 -10A, 15A VNC3 -20A VNC4 -25A VNC5 -32A, 32F VNC6 -40A, 40F VNC7 -50A, 50F No.